Technical analysis of power factor improvement using ETAP 12.6 at Regent Resort & Holiday Inn Canggu
Matrix: Jurnal Manajemen Teknologi dan Informatika · Vol. 12 No. 1 (2022) · pp. 38–50
ISSN 2580-5630, 2088-284X
Published 2022-03-29
Publisher Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Language eng
Abstract
Due to the increase of inductive load will cause a decrease in the power factor which in turn affects the distribution of electrical energy. The power factor improvement method was chosen by the Regent of Resort & Holiday Inn Canggu to meet the PLN Standard, SPLN 70-1, namely: the power factor must be > 0.85 is to install a capacitor bank. In addition to increasing the power factor, the installation of this capacitor bank is also expected to reduce power losses and voltage drops and avoid excess kVARh charges imposed by PLN. Through calculations and simulations using the ETAP 12.6 application, it is obtained that; To increase the power factor close to 0.95, 900kVAR power is required from the capacitor bank installed in LVMDP1 and LMPDP2 to compensate for the reactive power of 875.44 kVAR and 860.92 kVAR, respectively. The capacity of the capacitor bank required for LVMDP1 and LVMDP2 is 19.85 x 10-3 Farad, with a capacity value for each step of 2.20 x 10-3 Farad. By installing a capacitor bank on LVMDP1 and LVMDP2, it can increase the power factor to 0.94 and 0.95 respectively, and reduce the percentage of reactive power usage to active power to 34.3% and 34.7%.
Collaboration network of the authors
5 authors ·
5 co-authorship links
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/MATRIX/oai, first harvested 19 Nov 2026, last seen 19 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Technical analysis of power factor improvement using ETAP 12.6 at Regent Resort & Holiday Inn Canggu</dc:title>
<dc:creator>Karmiathi, Ni Made</dc:creator>
<dc:creator>Adiana Putra , I Kadek </dc:creator>
<dc:subject xml:lang="en-US">capacitor bank</dc:subject>
<dc:subject xml:lang="en-US">power factor</dc:subject>
<dc:subject xml:lang="en-US">reactive power</dc:subject>
<dc:description xml:lang="en-US">Due to the increase of inductive load will cause a decrease in the power factor which in turn affects the distribution of electrical energy. The power factor improvement method was chosen by the Regent of Resort &amp; Holiday Inn Canggu to meet the PLN Standard, SPLN 70-1, namely: the power factor must be &gt; 0.85 is to install a capacitor bank. In addition to increasing the power factor, the installation of this capacitor bank is also expected to reduce power losses and voltage drops and avoid excess kVARh charges imposed by PLN. Through calculations and simulations using the ETAP 12.6 application, it is obtained that; To increase the power factor close to 0.95, 900kVAR power is required from the capacitor bank installed in LVMDP1 and LMPDP2 to compensate for the reactive power of 875.44 kVAR and 860.92 kVAR, respectively. The capacity of the capacitor bank required for LVMDP1 and LVMDP2 is 19.85 x 10-3 Farad, with a capacity value for each step of 2.20 x 10-3 Farad. By installing a capacitor bank on LVMDP1 and LVMDP2, it can increase the power factor to 0.94 and 0.95 respectively, and reduce the percentage of reactive power usage to active power to 34.3% and 34.7%.</dc:description>
<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
<dc:date>2022-03-29</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ojs2.pnb.ac.id/index.php/MATRIX/article/view/402</dc:identifier>
<dc:identifier>10.31940/matrix.v12i1.38-50</dc:identifier>
<dc:source xml:lang="en-US">Matrix : Jurnal Manajemen Teknologi dan Informatika; Vol. 12 No. 1 (2022): Matrix: Jurnal Manajemen Teknologi dan Informatika; 38-50</dc:source>
<dc:source>2580-5630</dc:source>
<dc:source>2088-284X</dc:source>
<dc:source>10.31940/matrix.v12i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ojs2.pnb.ac.id/index.php/MATRIX/article/view/402/209</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2022 Matrix : Jurnal Manajemen Teknologi dan Informatika</dc:rights>
<dc:rights xml:lang="en-US">https://scholar.google.co.id/citations?user=NDE5gXYAAAAJ&hl=id</dc:rights>
</oai_dc:dc>
Citations and indexing
OpenAlex
Indexed
via DOI
6 citations
Crossref
Indexed
via DOI
2 citations
Counts as reported by each index on 19 Nov 2026; indexes count citations differently.
OpenAlex also lists this work in: crossref, doaj.
Cite this article
APA 7
Karmiathi, N. M., & Adiana Putra, I. K. (2022). Technical analysis of power factor improvement using ETAP 12.6 at Regent Resort & Holiday Inn Canggu. Matrix: Jurnal Manajemen Teknologi dan Informatika, 12(1), 38–50. https://doi.org/10.31940/matrix.v12i1.38-50
Copy
IEEE
N. M. Karmiathi and I. K. Adiana Putra, “Technical analysis of power factor improvement using ETAP 12.6 at Regent Resort & Holiday Inn Canggu,” Matrix: Jurnal Manajemen Teknologi dan Informatika, vol. 12, no. 1, pp. 38–50, 2022, doi: 10.31940/matrix.v12i1.38-50.
Copy
Generated from the journal's metadata; check author names before use.