Melola Discovery

← Melola Discovery

Journal SINTA 3

Data acquisition of flow sensor based to measure water flow in underground drainage

Matrix: Jurnal Manajemen Teknologi dan Informatika · Vol. 15 No. 1 (2025) · pp. 9–20

DOI
10.31940/matrix.v15i1.9-20
ISSN
2580-5630, 2088-284X
Published
2025-03-31
Publisher
Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali
Language
eng

Abstract

This research focuses on water flow sensors in underground drainage. In Indonesia, the use of sensors and actuators to control and measure water velocity and water discharge in underground drainage is not very popular, although one of the causes of flooding is caused by clogged drainage or workers forgetting to turn on the pump at a certain height and water flow. This paper will explain how to find out the speed and discharge of water in an underground drainage without checking it directly on site. The water flow sensor is used to measure the water velocity and water discharge entering a drainage system. The data acquisition conducted with 3 section, data preparation, data collecting, and data processing. Data preparation is preparing the microcontroller, sensor, and data display to get the data. Data collecting is about collecting the data from sensor in this research the data collected is in pulse that can be calculated to water discharge and water velocity in the data processing. From the experiment, it can be seen that the highest error rate on the sensor is 7.64% and the lowest at 0% or no error with the average amount of error is 2.46%. The data obtained from the sensor can be converted into water velocity and water discharge depending on the shape of the drainage. The length, width and height of the drainage are assumed to be 10x4x3 m respectively, with a constant water level of 2 m, so the water flow sensor is placed at a height of 1 m because the safe height is 1 m. From the case study conducted the error rate of the water flow sensor error is 0%, because the case study conducted using imaginary data. Based from this, the knowledge gained from the research, it can be used to determine the water velocity and water discharge value of underground drainage using water flow sensor, which is expected to be applied to pump houses to more easily determine the state of drainage.

Keywords

Collaboration network of the authors

31 authors · 89 co-authorship links · 2 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Politeknik Elektronika Negeri Surabaya
  • National Taiwan University of Science and Technology
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Bih‐Hwang LeeNational Taiwan University of Science and Technology1
Amang SudarsonoPoliteknik Elektronika Negeri Surabaya1
Iwan SyarifPoliteknik Elektronika Negeri Surabaya1
Fachrul RoziePoliteknik Elektronika Negeri Surabaya1
Edi SatriyantoPoliteknik Elektronika Negeri Surabaya1
Desy Intan PermatasariPoliteknik Elektronika Negeri Surabaya1
Yuliarta Rizki NusantokoPoliteknik Elektronika Negeri Surabaya1
Prima KristalinaPoliteknik Elektronika Negeri Surabaya1
Haniif Mulya WicaksanaPoliteknik Elektronika Negeri Surabaya1
Audra Annisa ZhafirahPoliteknik Elektronika Negeri Surabaya1
Mohammad SyafrudinPoliteknik Elektronika Negeri Surabaya1
BAMBANG SUMANTRIPoliteknik Elektronika Negeri Surabaya1
Rika RokhanaPoliteknik Elektronika Negeri Surabaya1
Santi AnggrainiPoliteknik Elektronika Negeri Surabaya1
Retno SukmaningrumPoliteknik Elektronika Negeri Surabaya1
Paulus Susetyo WardanaPoliteknik Elektronika Negeri Surabaya1
Agrippina Waya Rahmaning GustiPoliteknik Elektronika Negeri Surabaya1
Moch. RochmadPoliteknik Elektronika Negeri Surabaya1
Kemalasari KemalasariPoliteknik Elektronika Negeri Surabaya1
Hendhi HermawanPoliteknik Elektronika Negeri Surabaya1
Zainal AriefPoliteknik Elektronika Negeri Surabaya1
Setiawardhana SetiawardhanaPoliteknik Elektronika Negeri Surabaya1
Putri LianaPoliteknik Elektronika Negeri Surabaya1
Bima Sena Bayu DewantaraPoliteknik Elektronika Negeri Surabaya1
Bagus Nugraha Deby AriyadiPoliteknik Elektronika Negeri Surabaya1
Jauari Akhmad Nur HasimPoliteknik Elektronika Negeri Surabaya1
M. Husni MubarrokPoliteknik Elektronika Negeri Surabaya1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://ojs2.pnb.ac.id/index.php/MATRIX/oai, first harvested 19 Nov 2026, last seen 19 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Data acquisition of flow sensor based to measure water flow in underground drainage</dc:title>
	<dc:creator>Wirama, I Made Adiswara</dc:creator>
	<dc:creator>Widodo, Rusminto Tjatur</dc:creator>
	<dc:creator>Al Rasyid, Muhammad Udin Harun</dc:creator>
	<dc:creator>Oktavianto, Hary</dc:creator>
	<dc:subject xml:lang="en-US">Microcontroller</dc:subject>
	<dc:subject xml:lang="en-US">Sensor</dc:subject>
	<dc:subject xml:lang="en-US">Underground Drainage</dc:subject>
	<dc:subject xml:lang="en-US">Water Discharge</dc:subject>
	<dc:subject xml:lang="en-US">Water Velocity</dc:subject>
	<dc:description xml:lang="en-US">This research focuses on water flow sensors in underground drainage. In Indonesia, the use of sensors and actuators to control and measure water velocity and water discharge in underground drainage is not very popular, although one of the causes of flooding is caused by clogged drainage or workers forgetting to turn on the pump at a certain height and water flow. This paper will explain how to find out the speed and discharge of water in an underground drainage without checking it directly on site. The water flow sensor is used to measure the water velocity and water discharge entering a drainage system. The data acquisition conducted with 3 section, data preparation, data collecting, and data processing. Data preparation is preparing the microcontroller, sensor, and data display to get the data. Data collecting is about collecting the data from sensor in this research the data collected is in pulse that can be calculated to water discharge and water velocity in the data processing. From the experiment, it can be seen that the highest error rate on the sensor is 7.64% and the lowest at 0% or no error with the average amount of error is 2.46%. The data obtained from the sensor can be converted into water velocity and water discharge depending on the shape of the drainage. The length, width and height of the drainage are assumed to be 10x4x3 m respectively, with a constant water level of 2 m, so the water flow sensor is placed at a height of 1 m because the safe height is 1 m. From the case study conducted the error rate of the water flow sensor error is 0%, because the case study conducted using imaginary data. Based from this, the knowledge gained from the research, it can be used to determine the water velocity and water discharge value of underground drainage using water flow sensor, which is expected to be applied to pump houses to more easily determine the state of drainage.</dc:description>
	<dc:publisher xml:lang="en-US">Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali</dc:publisher>
	<dc:date>2025-03-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs2.pnb.ac.id/index.php/MATRIX/article/view/2467</dc:identifier>
	<dc:identifier>10.31940/matrix.v15i1.9-20</dc:identifier>
	<dc:source xml:lang="en-US">Matrix : Jurnal Manajemen Teknologi dan Informatika; Vol. 15 No. 1 (2025): Matrix: Jurnal Manajemen Teknologi dan Informatika; 9-20</dc:source>
	<dc:source>2580-5630</dc:source>
	<dc:source>2088-284X</dc:source>
	<dc:source>10.31940/matrix.v15i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs2.pnb.ac.id/index.php/MATRIX/article/view/2467/1128</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Matrix : Jurnal Manajemen Teknologi dan Informatika</dc:rights>
	<dc:rights xml:lang="en-US">https://scholar.google.co.id/citations?user=NDE5gXYAAAAJ&amp;hl=id</dc:rights>
</oai_dc:dc>