Melola Discovery

← Melola Discovery

Journal SINTA 1

CYTOLOGIC EXAMINATION USING SWAB METHOD TO EVALUATE RADIOLOGIC OUTCOME IN NASOPHARYNGEAL CARCINOMA PATIENTS POST-RADIOTHERAPY

Folia Medica Indonesiana · Vol. 43 No. 4 (2007)

ISSN
2355-8393, 2599-056X
Published
2007-10-01
Publisher
Airlangga University
Language
en

Abstract

Blind biopsy is still a standard procedure for the evaluation of NPC patients after radiotherapy in Oncology Clinic at ENT Department, Dr Soetomo Hospital. There is a problem in this procedure for patients because blind biopsy method could make bleeding and pain. The swab method was conducted by scraping nasopharyngeal area. This method has minimal injury, bleeding and painless. The result was quicker, cheaper as compared to blind biopsy. Swab method had been reported as having low accuracy as compared to blind biopsy to diagnose NPC. The purpose of this study was to analyze of different results of swab method and blind biopsy in patients of NPC after radiotherapy. The diagnostic test study was done by cross sectional comparative design. The population was NPC patients who had total dose of radiotherapy in Radiotherapy Installation, Dr Soetomo Hospital. The samples were taken by consecutive sampling to incoming patients at Oncology Clinic, ENT Department, Dr. Soetomo Hospital during the period of January to May 2005. There were 40 samples to study. The results of cytology and histopathology of the swab method and the blind biopsy in seven patients had a result of positive swab and positive biopsy. Two patients had a result of positive swab and negative biopsy. Three patients had a result of negative swab and positive biopsy. Twenty-eight patients had a result of negative swab and negative biopsy. Statistical analysis of the results with McNemar s test was p = 1.000. This means that there was no significant difference (p > 0.05) between the results of swab method and blind biopsy. The swab method had the sensitivity of 70%, the specificity of 93.3%, the positive predictive value was 77.8%, the negative predictive value was 90.3%, and the accuracy was 87.5%. The conclusion of this study was that the swab method can be a substitution of blind biopsy to evaluate NPC patients after radiotherapy.

Keywords

Collaboration network of the authors

7 authors · 10 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universitas Airlangga
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Eunike LayUniversitas Airlangga1
Retno HandajaniUniversitas Airlangga1
Harianto NotopuroUniversitas Airlangga1
Francisca NotopuroAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210179714, first harvested 19 Nov 2026, last seen 19 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">CYTOLOGIC EXAMINATION USING SWAB METHOD TO EVALUATE RADIOLOGIC OUTCOME IN NASOPHARYNGEAL CARCINOMA PATIENTS POST-RADIOTHERAPY</dc:title><dc:creator>OE Palandeng</dc:creator><dc:creator>Hoetomo</dc:creator><dc:creator>Widodo Ario Kentjono</dc:creator><dc:subject>nasopharyngeal carcinoma</dc:subject><dc:subject>blind biopsy</dc:subject><dc:subject>post-radiotherapy follow-up</dc:subject><dc:subject>diagnostic accuracy</dc:subject><dc:subject>histopathology</dc:subject><dc:subject>minimally invasive sampling</dc:subject><dc:description xml:lang="en">Blind biopsy is still a standard procedure for the evaluation of NPC patients after radiotherapy in Oncology Clinic at ENT Department, Dr Soetomo Hospital. There is a problem in this procedure for patients because blind biopsy method could make bleeding and pain. The swab method was conducted by scraping nasopharyngeal area. This method has minimal injury, bleeding and painless. The result was quicker, cheaper as compared to blind biopsy. Swab method had been reported as having low accuracy as compared to blind biopsy to diagnose NPC. The purpose of this study was to analyze of different results of swab method and blind biopsy in patients of NPC after radiotherapy. The diagnostic test study was done by cross sectional comparative design. The population was NPC patients who had total dose of radiotherapy in Radiotherapy Installation, Dr Soetomo Hospital. The samples were taken by consecutive sampling to incoming patients at Oncology Clinic, ENT Department, Dr. Soetomo Hospital during the period of January to May 2005. There were 40 samples to study. The results of cytology and histopathology of the swab method and the blind biopsy in seven patients had a result of positive swab and positive biopsy. Two patients had a result of positive swab and negative biopsy. Three patients had a result of negative swab and positive biopsy. Twenty-eight patients had a result of negative swab and negative biopsy. Statistical analysis of the results with McNemar s test was p = 1.000. This means that there was no significant difference (p &gt; 0.05) between the results of swab method and blind biopsy. The swab method had the sensitivity of 70%, the specificity of 93.3%, the positive predictive value was 77.8%, the negative predictive value was 90.3%, and the accuracy was 87.5%. The conclusion of this study was that the swab method can be a substitution of blind biopsy to evaluate NPC patients after radiotherapy.</dc:description><dc:publisher>Airlangga University</dc:publisher><dc:date>2007-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://journal.unair.ac.id/filerPDF/03%20PalendengE%20(format%20FMI).pdf</dc:identifier><dc:source>Folia Medica Indonesiana; Vol 43 No 4 (2007)</dc:source><dc:source>2355-8393</dc:source><dc:source>2599-056X</dc:source><dc:language>en</dc:language></oai_dc:dc>