Melola Discovery

← Melola Discovery

Journal SINTA 1

MEAN SCORE OF CERVICAL PEDICLE ANGLE TO MIDLINE AND INFERIOR END PLATE IN ADULT USING MULTI SLICED COMPUTED TOMOGRAPHY

Folia Medica Indonesiana · Vol. 50 No. 1 (2014)

ISSN
2355-8393, 2599-056X
Published
2014-01-01
Publisher
Airlangga University
Language
en

Abstract

Cervical pedicle screw provides multiple benefits to the posterior cervical fixation, that is the strength of load and better control onthe field of coronal, sagittal, and rotational because of the three-column fixation. However, cervical pedicle screw installation cancause neurological and vascular complications. This Descriptive study with a sample of 30 people was aimed to calculate the meanscore of cervical pedicle angle toward the midline and the end plate inferior in normal asymptomatic adults using MSCT atlaboratory Radiology MSCT Graha Amerta Dr. Soetomo Hospital Surabaya in February-June 2010. Among 19 men and 11 women,obtained mean score of cervical pedicle angle to the midline of men is 43.11° to 45.84° on the right side, 43.32° to 45.94° on the leftside, and 43.11° to 45.94° overall. In women, the value is 44.66° to 48.54° on the right side, 45.03° to 48.56° on the left side, and45.03° to 48.56° overall. Mean score of cervical pedicle angle to the end plate inferior on men is 12.47° to 15° on the right side,11.36° to 14.10° on the left side, and 11.3° to 15° overall. While women at 11.48° to 15.03° on the right side, 11.28° to 15.17° on theleft side and 11.28° to 15.17° overall. Cervical pedicle diameter in men ranging from 4.85 mm (SD ± 0.62) to 6.17 mm (SD ± 0.67),in women 4,08 mm (SD ± 0.75) to 5.69 mm (SD ± 0.69). There are differences in cervical pedicle angle to the midline and end plateinferior between men and women. (FMI 2014;50 58-62)

Keywords

Collaboration network of the authors

10 authors · 16 co-authorship links · 1 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Parahyangan Catholic University
  • Mercu Buana University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Martin WijayaParahyangan Catholic University3
Aswin LimParahyangan Catholic University2
Yohanes Albrecht MontolParahyangan Catholic University1
Ahmad Kemal ArsyadAffiliation unknown1
Grisella AgliaParahyangan Catholic University1
Edwin LieParahyangan Catholic University1
Ramli NazirAffiliation unknown1
Desiana VidayantiMercu Buana University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210179714, first harvested 19 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">MEAN SCORE OF CERVICAL PEDICLE ANGLE TO MIDLINE AND INFERIOR END PLATE IN ADULT USING MULTI SLICED COMPUTED TOMOGRAPHY</dc:title><dc:creator>Ardhiana Kasaba</dc:creator><dc:creator>Paulus Pramono Rahardjo</dc:creator><dc:subject>cervical pedicle screw</dc:subject><dc:subject>pedicle width</dc:subject><dc:subject>pedicle screw placement</dc:subject><dc:subject>sex differences</dc:subject><dc:subject>posterior cervical fixation</dc:subject><dc:subject>normal anatomical values</dc:subject><dc:subject>adults</dc:subject><dc:subject>multidetector computed tomography</dc:subject><dc:subject>pedicle screw complications</dc:subject><dc:subject>pedicle screw malposition</dc:subject><dc:description xml:lang="en">Cervical pedicle screw provides multiple benefits to the posterior cervical fixation, that is the strength of load and better control onthe field of coronal, sagittal, and rotational because of the three-column fixation. However, cervical pedicle screw installation cancause neurological and vascular complications. This Descriptive study with a sample of 30 people was aimed to calculate the meanscore of cervical pedicle angle toward the midline and the end plate inferior in normal asymptomatic adults using MSCT atlaboratory Radiology MSCT Graha Amerta Dr. Soetomo Hospital Surabaya in February-June 2010. Among 19 men and 11 women,obtained mean score of cervical pedicle angle to the midline of men is 43.11° to 45.84° on the right side, 43.32° to 45.94° on the leftside, and 43.11° to 45.94° overall. In women, the value is 44.66° to 48.54° on the right side, 45.03° to 48.56° on the left side, and45.03° to 48.56° overall. Mean score of cervical pedicle angle to the end plate inferior on men is 12.47° to 15° on the right side,11.36° to 14.10° on the left side, and 11.3° to 15° overall. While women at 11.48° to 15.03° on the right side, 11.28° to 15.17° on theleft side and 11.28° to 15.17° overall. Cervical pedicle diameter in men ranging from 4.85 mm (SD ± 0.62) to 6.17 mm (SD ± 0.67),in women 4,08 mm (SD ± 0.75) to 5.69 mm (SD ± 0.69). There are differences in cervical pedicle angle to the midline and end plateinferior between men and women. (FMI 2014;50 58-62)</dc:description><dc:publisher>Airlangga University</dc:publisher><dc:date>2014-01-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://journal.unair.ac.id/article_7546_media3_category3.html</dc:identifier><dc:source>Folia Medica Indonesiana; Vol 50 No 1 (2014)</dc:source><dc:source>2355-8393</dc:source><dc:source>2599-056X</dc:source><dc:language>en</dc:language></oai_dc:dc>