Abstract

Purpose: The purpose of this study was to investigate and compare the accuracy of two procedures: open tray with splinting technique and closed tray impression techniques, in innovative in vitro experiments. Materials and Methods: One master cast was fabricated with 4 abutment replica implants with almost parallel position in an anterior region of an edentuloys mandibular plaster cast. The working cast was taken impessions with open tray splinting technique (group 1) and closed tray technique (group 2) using polyvinyl siloxane impression material. The Type III dental stone ws poured into around the impressions. The accuracy of impression procedured were measured 24 hours long after pouring dental stone to each impression. Four sited were marked to measured on every platform of implant analogs. The analyzing stylus was positioned to each site and the heights, horizontal inclination and saggital incliniation were measured using the Laser displacement transducer (LK G115; Keyence, Osaka, Japan). Measurements of these 16 points of four implants per a model was repeated 7 times under the same condition. The gap between the abutment and superstructure at one screw test was evaluated with a digital microscope system (VH-Z100 & VH-5000; Keyence, Osaka, Japan). The mean and standard deviation estimated from the samples of each subgroup were statistically analyzed by ANOVA test (P<0.05 as the level of significance). Results: The relative differences of implant heights, horizontal inclination and saggital inclination of each implant on closed tray technique was statistically different to master cast and open tray with splinting (P<0.005). Conclusion: The open tray technique was more accurate comparing to the closed tray technique. The gap between the abutment and superstructure in the open tray with splinting technique was smaller comparing to closed tray technique. DOI: 10.14693/jdi.v17i1.111

Keywords

Collaboration network of the authors

15 authors · 42 co-authorship links · 23 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universitas Hang Tuah
  • Tokushima University
  • Universitas Airlangga
  • Tokushima University Hospital
  • Universitas Negeri Surabaya
  • Institut Teknologi Sepuluh Nopember
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Anita YuliatiUniversitas Airlangga1
Coen Pramono DUniversitas Airlangga1
Endah WahjuningsihUniversitas Hang Tuah1
Widyasri PrananingrumUniversitas Hang Tuah1
Fitria RahmitasariUniversitas Hang Tuah1
Sri FatmawatiInstitut Teknologi Sepuluh Nopember1
Grace Caroline SetiawanUniversitas Hang Tuah1
Vindya Meinda PutriUniversitas Hang Tuah1
Baiq Nadia Risna WahyuningUniversitas Hang Tuah1
Nurina Rizka RamadhaniaUniversitas Negeri Surabaya1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2736430281, first harvested 22 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Evaluation in Accuracy to Two Impression Techniques: In Case of Bone Anchored Bridge</dc:title><dc:creator>Sularsih Sularsih</dc:creator><dc:creator>Osamu Ishida</dc:creator><dc:creator>Meinar Nur Ashrin</dc:creator><dc:creator>Masayo Okajima</dc:creator><dc:creator>Tetsuo Ichikawa</dc:creator><dc:subject>dental impression accuracy</dc:subject><dc:subject>implant-supported bridges</dc:subject><dc:subject>polyvinyl siloxane impressions</dc:subject><dc:subject>implant abutments</dc:subject><dc:subject>dental stone casts</dc:subject><dc:subject>laser displacement measurement</dc:subject><dc:description xml:lang="en">Purpose: The purpose of this study was to investigate and compare the accuracy of two procedures: open tray with splinting technique and closed tray impression techniques, in innovative in vitro experiments. Materials and Methods: One master cast was fabricated with 4 abutment replica implants with almost parallel position in an anterior region of an edentuloys mandibular plaster cast. The working cast was taken impessions with open tray splinting technique (group 1) and closed tray technique (group 2) using polyvinyl siloxane impression material. The Type III dental stone ws poured into around the impressions. The accuracy of impression procedured were measured 24 hours long after pouring dental stone to each impression. Four sited were marked to measured on every platform of implant analogs. The analyzing stylus was positioned to each site and the heights, horizontal inclination and saggital incliniation were measured using the Laser displacement transducer (LK G115; Keyence, Osaka, Japan). Measurements of these 16 points of four implants per a model was repeated 7 times under the same condition. The gap between the abutment and superstructure at one screw test was evaluated with a digital microscope system (VH-Z100 &amp; VH-5000; Keyence, Osaka, Japan). The mean and standard deviation estimated from the samples of each subgroup were statistically analyzed by ANOVA test (P&lt;0.05 as the level of significance). Results: The relative differences of implant heights, horizontal inclination and saggital inclination of each implant on closed tray technique was statistically different to master cast and open tray with splinting (P&lt;0.005). Conclusion: The open tray technique was more accurate comparing to the closed tray technique. The gap between the abutment and superstructure in the open tray with splinting technique was smaller comparing to closed tray technique. DOI: 10.14693/jdi.v17i1.111</dc:description><dc:publisher>University of Indonesia</dc:publisher><dc:date>2013-07-29</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.14693/jdi.v17i1.111</dc:identifier><dc:identifier>10.14693/jdi.v17i1.111</dc:identifier><dc:source>Journal of Dentistry Indonesia; Vol 17 No 1 (2013); 28-36</dc:source><dc:source>1693-9697</dc:source><dc:source>2355-4800</dc:source><dc:language>en</dc:language></oai_dc:dc>