Abstract

Hand gesture detection with a smartwatch can be used as a smart lighting control on the internet of things (IoT) environment using machine learning techniques such as support vector machine (SVM). However, several parameters affect the SVM model's performance and need to be evaluated. This study evaluates the parameters in building an SVM model for hand gesture detection in intelligent lighting control. In this study, eight gestures were defined to turn on and off four different lights, and then the data were collected through a smartwatch with an Inertial Measurement Unit (IMU) sensor. Feature selection using Pearson Correlation is then carried out on 36 features extracted from each gesture data. Finally, two sets of gestures were compared to evaluate the effect of gesture selection on model performance. The first set of gestures show that the accuracy of 10 features compared to the accuracy of 36 features is 94% compared to 71%, respectively. Furthermore, the second set of gestures has an accuracy lower than the first set of gestures, which is 64%. Results show that the lower the number of features, the better the accuracy. Then, the set of gestures that are not too distinctive show lower accuracy than the highly distinctive gesture sets. The conclusion is, in implementing gesture detection with SVM, low data dimensions need to be maintained through feature selection methods, and a distinctive set of gesture selection is required for a model with good performance.

Keywords

Collaboration network of the authors

11 authors · 17 co-authorship links · 1 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Telkom University
  • Institut Teknologi Telkom Purwokerto
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nur Ghaniaviyanto RamadhanInstitut Teknologi Telkom Purwokerto1
Ikke Dian OktavianiTelkom University1
Vera SuryaniTelkom University1
Andrian RakhmatsyahTelkom University1
Kinkin AgustrianaTelkom University1
Maman AbdurohmanTelkom University1
Doan PerdanaTelkom University1
Hilal Hudan NuhaTelkom University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210188896, first harvested 19 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">An Evaluation of SVM in Hand Gesture Detection Using IMU-Based Smartwatches for Smart Lighting Control</dc:title><dc:creator>Maya Ameliasari</dc:creator><dc:creator>Aji Gautama Putrada</dc:creator><dc:creator>Rizka Reza Pahlevi</dc:creator><dc:subject>hand gesture detection</dc:subject><dc:subject>support vector machine</dc:subject><dc:subject>smartwatches</dc:subject><dc:subject>inertial measurement unit</dc:subject><dc:subject>intelligent lighting control</dc:subject><dc:subject>Internet of Things</dc:subject><dc:subject>feature selection</dc:subject><dc:subject>Pearson correlation</dc:subject><dc:subject>wearable sensors</dc:subject><dc:description xml:lang="en">Hand gesture detection with a smartwatch can be used as a smart lighting control on the internet of things (IoT) environment using machine learning techniques such as support vector machine (SVM). However, several parameters affect the SVM model's performance and need to be evaluated. This study evaluates the parameters in building an SVM model for hand gesture detection in intelligent lighting control. In this study, eight gestures were defined to turn on and off four different lights, and then the data were collected through a smartwatch with an Inertial Measurement Unit (IMU) sensor. Feature selection using Pearson Correlation is then carried out on 36 features extracted from each gesture data. Finally, two sets of gestures were compared to evaluate the effect of gesture selection on model performance. The first set of gestures show that the accuracy of 10 features compared to the accuracy of 36 features is 94% compared to 71%, respectively. Furthermore, the second set of gestures has an accuracy lower than the first set of gestures, which is 64%. Results show that the lower the number of features, the better the accuracy. Then, the set of gestures that are not too distinctive show lower accuracy than the highly distinctive gesture sets. The conclusion is, in implementing gesture detection with SVM, low data dimensions need to be maintained through feature selection methods, and a distinctive set of gesture selection is required for a model with good performance.</dc:description><dc:publisher>LPPM Institut Teknologi Telkom Purwokerto</dc:publisher><dc:date>2021-05-30</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.20895/infotel.v13i2.656</dc:identifier><dc:identifier>10.20895/infotel.v13i2.656</dc:identifier><dc:source>JURNAL INFOTEL; Vol 13 No 2 (2021); 47-53</dc:source><dc:source>2085-3688</dc:source><dc:source>2460-0997</dc:source><dc:language>en</dc:language><dc:relation>https://ejournal.st3telkom.ac.id/index.php/infotel/article/download/656/328</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>