Design of machine learning-based water quality prediction system with recursive feature elimination cross-validation

JURNAL INFOTEL · Vol. 15 No. 3 (2023) · pp. 249–255

DOI
10.20895/infotel.v15i3.977
ISSN
2085-3688, 2460-0997
Published
2023-09-05
Publisher
LPPM Institut Teknologi Telkom Purwokerto
Language
en
License
creativecommons.org/licenses/by-sa/4.0/

Abstract

Lack of clean water has become a problem in the world, and it is estimated that by 2025 there will be 2.8 billion people who will experience a shortage of clean water. The high demand for clean water and the limited water sources with proper potency is one of the main reasons for the need for a device capable of measuring the potability level of water that is flexible to carry and does not require high costs in the manufacturing process. In this paper, the design of machine learning-based potability devices with recursive feature elimination with cross-validation (RFECV) is carried out as a guide in making the design of a water potability detection system, and the results obtained from RFECV with the Random Forest (RF) algorithm have a higher accuracy value. 15.71% better than the RF model, 6.85% better than the Support Vector Machine (SVM) model, and 8.57% better than the Artificial Neural Network (ANN) model trained without RFECV. The water potability prediction system's design selection is based on feature elimination results in the RFECV process. It is based on a literature review on device selection. The proposed water potability detection system consists of ESP32 as the primary computing device, electrochemical spectroscopy-based Al/PET sensor to detect sulfate values with a sensitivity of 0.874 Ω/ppm, PH4502C as a pH measuring instrument with an accuracy of up to 98.10%, WD-35802-49 electrode. as a device for measuring hardness in water with a measurement range of 0.4 – 40,000 ppm, a total dissolved solids sensor to determine the solids content in water with an accuracy of up to 97.80%, as well as a carbon-based sensor for measuring chloramines with a reading capacity of 186 nA/ppm.

Keywords

Collaboration network of the authors

14 authors · 53 co-authorship links · 9 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universitas Pembangunan Nasional Veteran Jakarta
  • Politeknik Negeri Bali
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Adi WinartaPoliteknik Negeri Bali6
Riki Hendra PurbaUniversitas Pembangunan Nasional Veteran Jakarta5
Elvi ErmadaniUniversitas Pembangunan Nasional Veteran Jakarta3
Fathin Muhammad MahdhudhuUniversitas Pembangunan Nasional Veteran Jakarta3
Nandy PutraAffiliation unknown3
Anggie Topan WijayaUniversitas Pembangunan Nasional Veteran Jakarta2
Fathin MadhudhuAffiliation unknown2
Rasya Aulia Nathania NisaUniversitas Pembangunan Nasional Veteran Jakarta2
Elvi ArmadaniUniversitas Pembangunan Nasional Veteran Jakarta2
Bima Rakha AdhitamaUniversitas Pembangunan Nasional Veteran Jakarta1
Fitri WahyuniUniversitas Pembangunan Nasional Veteran Jakarta1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210188896, first harvested 19 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Design of machine learning-based water quality prediction system with recursive feature elimination cross-validation</dc:title><dc:creator>James Julian</dc:creator><dc:creator>Annastya Bagas Dewantara</dc:creator><dc:creator>Fitri Wahyuni</dc:creator><dc:subject>water quality monitoring</dc:subject><dc:subject>recursive feature elimination</dc:subject><dc:subject>random forest</dc:subject><dc:subject>electrochemical sensor</dc:subject><dc:subject>sulfate determination</dc:subject><dc:subject>pH measurement</dc:subject><dc:subject>water hardness</dc:subject><dc:subject>total dissolved solids</dc:subject><dc:subject>low-cost sensors</dc:subject><dc:subject>ESP32 microcontroller</dc:subject><dc:description xml:lang="en">Lack of clean water has become a problem in the world, and it is estimated that by 2025 there will be 2.8 billion people who will experience a shortage of clean water. The high demand for clean water and the limited water sources with proper potency is one of the main reasons for the need for a device capable of measuring the potability level of water that is flexible to carry and does not require high costs in the manufacturing process. In this paper, the design of machine learning-based potability devices with recursive feature elimination with cross-validation (RFECV) is carried out as a guide in making the design of a water potability detection system, and the results obtained from RFECV with the Random Forest (RF) algorithm have a higher accuracy value. 15.71% better than the RF model, 6.85% better than the Support Vector Machine (SVM) model, and 8.57% better than the Artificial Neural Network (ANN) model trained without RFECV. The water potability prediction system's design selection is based on feature elimination results in the RFECV process. It is based on a literature review on device selection. The proposed water potability detection system consists of ESP32 as the primary computing device, electrochemical spectroscopy-based Al/PET sensor to detect sulfate values with a sensitivity of 0.874 Ω/ppm, PH4502C as a pH measuring instrument with an accuracy of up to 98.10%, WD-35802-49 electrode. as a device for measuring hardness in water with a measurement range of 0.4 – 40,000 ppm, a total dissolved solids sensor to determine the solids content in water with an accuracy of up to 97.80%, as well as a carbon-based sensor for measuring chloramines with a reading capacity of 186 nA/ppm.</dc:description><dc:publisher>LPPM Institut Teknologi Telkom Purwokerto</dc:publisher><dc:date>2023-09-05</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.20895/infotel.v15i3.977</dc:identifier><dc:identifier>10.20895/infotel.v15i3.977</dc:identifier><dc:source>JURNAL INFOTEL; Vol 15 No 3 (2023); 249-255</dc:source><dc:source>2085-3688</dc:source><dc:source>2460-0997</dc:source><dc:language>en</dc:language><dc:relation>https://ejournal.ittelkom-pwt.ac.id/index.php/infotel/article/download/977/455</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>