Perancangan dan Implementasi Cyclic Redundancy Check – 16 sebagai Metode Error Checking pada Transmisi Pesan Protokol Modbus Remote Terminal Unit Berbasis Microcontroller Unit
Jurnal Nasional Teknik Elektro · Vol. 5 No. 1 (2016) · pp. 98–98
ISSN 2302-2949, 2407-7267
Published 2016-03-11
Publisher Andalas University
Language id
Abstract
This paper presents about the Cyclic Redundancy Check – 16, a generator polynomial for error detection, which is normally used in MODBUS Remote Terminal Unit. It starts with explaining the noise phenomena that are often generated into a useful signal when it is transmitted through a noisy channel. Some types of error which usually affects bits of a transmitted data bytes are introduced. The complete method for designing a good generator polynomial for detecting the error is then presented. Next, Cyclic Redundancy Check -16 as an example of generator polynimial is discussed. The explanation includes method for software implementation of the CRC. Two methods are introduced which are loop – driven method and table - driven method. Finally, result of designed generator polynomial is shown, which consists of the algorithm and the routine example. The CRC -16 routine is then tested using some MODBUS messages.Keywords - Noise, generator polynomial, Cyclic Redundancy Check, MODBUS Remote Terminal Unit, lood – driven, table – driven, algorithm.Abstrak-Paper
Collaboration network of the authors
11 authors ·
18 co-authorship links
· 8 across different organisations
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
Universitas Gadjah Mada Muhammadiyah University of Yogyakarta Jenderal Soedirman University Soegijapranata Catholic University Affiliation unknown
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175326, first harvested 22 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="id">Perancangan dan Implementasi Cyclic Redundancy Check – 16 sebagai Metode Error Checking pada Transmisi Pesan Protokol Modbus Remote Terminal Unit Berbasis Microcontroller Unit</dc:title><dc:creator>Arief Wisnu Wardana</dc:creator><dc:creator>Eka Firmansyah</dc:creator><dc:creator>Addin Suwastono</dc:creator><dc:subject>cyclic redundancy check</dc:subject><dc:subject>CRC-16</dc:subject><dc:subject>generator polynomials</dc:subject><dc:subject>error detection</dc:subject><dc:subject>Modbus</dc:subject><dc:subject>remote terminal units</dc:subject><dc:subject>microcontroller</dc:subject><dc:subject>data transmission</dc:subject><dc:subject>channel noise</dc:subject><dc:subject>data integrity verification</dc:subject><dc:subject>industrial communication networks</dc:subject><dc:description xml:lang="id">This paper presents about the Cyclic Redundancy Check – 16, a generator polynomial for error detection, which is normally used in MODBUS Remote Terminal Unit. It starts with explaining the noise phenomena that are often generated into a useful signal when it is transmitted through a noisy channel. Some types of error which usually affects bits of a transmitted data bytes are introduced. The complete method for designing a good generator polynomial for detecting the error is then presented. Next, Cyclic Redundancy Check -16 as an example of generator polynimial is discussed. The explanation includes method for software implementation of the CRC. Two methods are introduced which are loop – driven method and table - driven method. Finally, result of designed generator polynomial is shown, which consists of the algorithm and the routine example. The CRC -16 routine is then tested using some MODBUS messages.Keywords - Noise, generator polynomial, Cyclic Redundancy Check, MODBUS Remote Terminal Unit, lood – driven, table – driven, algorithm.Abstrak-Paper</dc:description><dc:publisher>Andalas University</dc:publisher><dc:date>2016-03-11</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.25077/jnte.v5n1.189.2016</dc:identifier><dc:identifier>10.25077/jnte.v5n1.189.2016</dc:identifier><dc:source>Jurnal Nasional Teknik Elektro; Vol 5 No 1 (2016); 98-98</dc:source><dc:source>2302-2949</dc:source><dc:source>2407-7267</dc:source><dc:language>id</dc:language><dc:relation>http://jnte.ft.unand.ac.id/index.php/jnte/article/download/189/217</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>
Citations and indexing
OpenAlex
Indexed
via ID karya OpenAlex (record dari sumber OpenAlex)
2 citations
Crossref
Indexed
via DOI
1 citation
Counts as reported by each index on 20 Nov 2026; indexes count citations differently.
OpenAlex also lists this work in: crossref, doaj.
Cite this article
APA 7
Wardana, A. W., Firmansyah, E., & Suwastono, A. (2016). Perancangan dan Implementasi Cyclic Redundancy Check – 16 sebagai Metode Error Checking pada Transmisi Pesan Protokol Modbus Remote Terminal Unit Berbasis Microcontroller Unit. Jurnal Nasional Teknik Elektro, 5(1), 98–98. https://doi.org/10.25077/jnte.v5n1.189.2016
Copy
IEEE
A. W. Wardana, E. Firmansyah, and A. Suwastono, “Perancangan dan Implementasi Cyclic Redundancy Check – 16 sebagai Metode Error Checking pada Transmisi Pesan Protokol Modbus Remote Terminal Unit Berbasis Microcontroller Unit,” Jurnal Nasional Teknik Elektro, vol. 5, no. 1, pp. 98–98, 2016, doi: 10.25077/jnte.v5n1.189.2016.
Copy
Generated from the journal's metadata; check author names before use.