This paper analyzes the effect of the presence of foreign particles on an equilateral arrangement of 3 phase gas insulated switchgear (GIS) insulation equipment. In this calculation, the electric field characteristics will be analyzed in 3-phase equilateral GIS by varying the location of the particles in the GIS tank. Particles are modeled to have a length of 5 mm and a thickness of 0.5 mm located in a 3 phase GIS equilateral arrangement with a tank diameter of 150 mm and a conductor diameter of 25 mm. The electric field calculations are reviewed at several points in the 3-phase equilateral GIS tank. The simulation and calculation of the electric field were calculated with FEM method software. The results of the calculations show that there are differences in the characteristics of the electric field between normal GIS and GIS where foreign particles are present. The difference in these characteristics can be seen in the magnitude of the electric field, and the ratio of eccentricity from some point of view.

Keywords

Collaboration network of the authors

28 authors · 68 co-authorship links · 27 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Andalas University
  • Universiti Sains Malaysia
  • Indonesian Institute of Sciences
  • Bandung Institute of Technology
  • National Research and Innovation Agency
  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • Sumatera Institute of Technology
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Agus RisdiyantoNational Research and Innovation Agency2
Noviadi Arief RachmanIndonesian Institute of Sciences2
Maulana ArifinIndonesian Institute of Sciences2
Agus Rahmad TimorAndalas University2
Nor Asiah MuhamadUniversiti Sains Malaysia1
Nazatul Shiema Moh NazarUniversiti Sains Malaysia1
Noor Syazwani MansorUniversiti Sains Malaysia1
Mariatti Jaafar MustaphaUniversiti Sains Malaysia1
Amir Izzani MohamedUniversiti Malaysia Pahang Al-Sultan Abdullah1
Mohamad Kamarol Mohd JamilUniversiti Sains Malaysia1
Abdul RajabAndalas University1
Andi PawawoiAndalas University1
Baharuddin BaharuddinAndalas University1
Harry GumilangAffiliation unknown1
Pinto AnugrahAndalas University1
Ariadi HazmiAndalas University1
Kiki KanandaSumatera Institute of Technology1
Zulka HendriAndalas University1
KhairullahAffiliation unknown1
ErliwatiAndalas University1
Baharuddin BaharuddinHasanuddin University1
Akbar Alhaqi HidayatAndalas University1
Rina AngrainiPoliteknik Negeri Padang1
Nofriadi NofriadiAffiliation unknown1
Syafii SyafiiAndalas University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175326, first harvested 22 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="id">Pengaruh Keberadaan Partikel Asing Terhadap Karakteristik Medan Listrik Pada GIS Equilateral Tiga Fasa</dc:title><dc:creator>Rizki Wahyu Pratama</dc:creator><dc:creator>Hanalde Andre</dc:creator><dc:creator>Umar Khayam</dc:creator><dc:subject>gas-insulated switchgear</dc:subject><dc:subject>foreign particles</dc:subject><dc:subject>electric field characteristics</dc:subject><dc:subject>eccentricity ratio</dc:subject><dc:subject>partial discharge</dc:subject><dc:description xml:lang="id">This paper analyzes the effect of the presence of foreign particles on an equilateral arrangement of 3 phase gas insulated switchgear (GIS) insulation equipment. In this calculation, the electric field characteristics will be analyzed in 3-phase equilateral GIS by varying the location of the particles in the GIS tank. Particles are modeled to have a length of 5 mm and a thickness of 0.5 mm located in a 3 phase GIS equilateral arrangement with a tank diameter of 150 mm and a conductor diameter of 25 mm. The electric field calculations are reviewed at several points in the 3-phase equilateral GIS tank. The simulation and calculation of the electric field were calculated with FEM method software. The results of the calculations show that there are differences in the characteristics of the electric field between normal GIS and GIS where foreign particles are present. The difference in these characteristics can be seen in the magnitude of the electric field, and the ratio of eccentricity from some point of view.</dc:description><dc:publisher>Andalas University</dc:publisher><dc:date>2021-03-09</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.25077/jnte.v10n1.850.2021</dc:identifier><dc:identifier>10.25077/jnte.v10n1.850.2021</dc:identifier><dc:source>Jurnal Nasional Teknik Elektro; Vol 10 No 1 (2021); 19-19</dc:source><dc:source>2302-2949</dc:source><dc:source>2407-7267</dc:source><dc:language>id</dc:language><dc:relation>http://jnte.ft.unand.ac.id/index.php/jnte/article/download/850/418</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>