Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Efek Pengintegrasian Pembangkit Listrik Tersebar pada Sistem Distribusi Radial terhadap Perbaikan Tegangan

Jurnal Nasional Teknik Elektro · Vol. 5 No. 1 (2016) · pp. 1–6

DOI
10.20449/jnte.v5i1.157
ISSN
2302-2949, 2407-7267
Published
2016-01-28
Publisher
Andalas University
Language
id
License
creativecommons.org/licenses/by-nc-sa/4.0/

Abstract

At 20 kV radial distribution systems supplied by the substation in a considerable distance from the load centre, will cause occurred its voltage drop significantly. The integration of distributed generation on the distribution networks will be one of the solutions to reduce the drop voltage. This paper proposes a way to analyze the effect of integration multiple distributed generation (DG) in radial distribution networks to the voltage drop. This analysis uses the injection current method of the load and the DG on each bus. The analysis results showed that the penetration of 5 units of DG on the distribution network will reduce its voltage drops significantly, especially on the adjacent bus with DG.

Keywords

Collaboration network of the authors

30 authors · 56 co-authorship links · 14 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Andalas University
  • Badan Pengkajian dan Penerapan Teknologi
  • Universitas Negeri Padang
  • Institut Teknologi Padang
  • Diponegoro University
  • Indian Institute of Technology Indore
  • Sumatera Institute of Technology
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Andi PawawoiAndalas University5
Fajril AkbarAndalas University5
Muhammad Imran HamidAndalas University2
Syafii SyafiiAndalas University2
Krismadinata KrismadinataUniversitas Negeri Padang2
Muhammad Imran HamidAndalas University1
Yudi ArfanAndalas University1
Syafii GhazaliAffiliation unknown1
Axel DorizaAndalas University1
Zuriman AnthonyInstitut Teknologi Padang1
Rizka AmaliaDiponegoro University1
Hasmat MalikIndian Institute of Technology Indore1
Dendi Adi SaputraAndalas University1
Igo Cikal MuharramAndalas University1
Asnil AsnilAndalas University1
Muhammad NasirAndalas University1
Mery DianaBadan Pengkajian dan Penerapan Teknologi1
Arief RufiyantoBadan Pengkajian dan Penerapan Teknologi1
Kiki KanandaSumatera Institute of Technology1
Dewi Purnama SariAndalas University1
Novi KurniasihAndalas University1
Melda LatifAndalas University1
Hamdi RezaAndalas University1
Rizka AmaliaAndalas University1
Wahyu Rizki MuslyadiAndalas University1
Mochammad RismansyahAndalas University1
Elsi Alfionita SyawalAndalas University1
Rahmat HidayatAndalas University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175326, first harvested 20 Nov 2026, last seen 20 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="id">Efek Pengintegrasian Pembangkit Listrik Tersebar pada Sistem Distribusi Radial terhadap Perbaikan Tegangan</dc:title><dc:creator>Eka Fitrianto</dc:creator><dc:creator>Refdinal Nazir</dc:creator><dc:subject>distributed generation</dc:subject><dc:subject>radial distribution systems</dc:subject><dc:subject>voltage drop</dc:subject><dc:subject>voltage improvement</dc:subject><dc:subject>distributed generation integration</dc:subject><dc:subject>DG penetration level</dc:subject><dc:subject>20 kV distribution network</dc:subject><dc:description xml:lang="id">At 20 kV radial distribution systems supplied by the substation in a considerable distance from the load centre, will cause occurred its voltage drop significantly. The integration of distributed generation on the distribution networks will be one of the solutions to reduce the drop voltage. This paper proposes a way to analyze the effect of integration multiple distributed generation (DG) in radial distribution networks to the voltage drop. This analysis uses the injection current method of the load and the DG on each bus. The analysis results showed that the penetration of 5 units of DG on the distribution network will reduce its voltage drops significantly, especially on the adjacent bus with DG.</dc:description><dc:publisher>Andalas University</dc:publisher><dc:date>2016-01-28</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.20449/jnte.v5i1.157</dc:identifier><dc:identifier>10.20449/jnte.v5i1.157</dc:identifier><dc:source>Jurnal Nasional Teknik Elektro; Vol 5 No 1 (2016); 1-6</dc:source><dc:source>2302-2949</dc:source><dc:source>2407-7267</dc:source><dc:language>id</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>