Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Low-Cost Multimodal Physiological Telemonitoring System through Internet of Things

Jurnal Elektronika dan Telekomunikasi · Vol. 21 No. 1 (2021) · pp. 55–63

DOI
10.14203/jet.v21.55-63
ISSN
1411-8289, 2527-9955
Published
2021-08-31
Publisher
Indonesian Institute of Sciences
Language
en
License
creativecommons.org/licenses/by-nc-sa/4.0/

Abstract

The objective of this study is to develop and test a patient telemonitoring system. This study was encouraged by the high number of health workers fatalities in Indonesia due to physical contact without proper protection. Based on the symptoms of COVID-19 it consists of electrocardiogram (ECG) sensors, body temperature sensors, respiratory rate sensors, and pulse oximeter. The physiological data were captured by the sensors and collected by a microcontroller then it sends the data to a cloud system so that health workers can access the data. The experiments were performed to test both the offline and online protocol to compare data sent via a direct connection and data sent via Wi-Fi. In the offline testing, there were several limitations observed such as the low sampling frequency of the ECG signals that reduce the fidelity of the signals. Such problems were also observed on respiratory rate data. Furthermore, the system is also very prone to subjects’ movement-related noise. The measurements of peripheral oxygen saturation (SpO2) and body temperature, on the other hand, have been detected the slight change up to 0.1% and 0.5oC respectively. In the online testing, the data transmission to the cloud is sent per 30 seconds so that morphologically the ECG signal data are not representative. The system requires a lot of improvements and future study should be directed to improve signals acquisition and processing while maintaining the concept of low-cost. Design improvement should also include a better attachment design to the human body as well as greater data transmission for the online system.

Keywords

Collaboration network of the authors

25 authors · 111 co-authorship links · 63 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Indonesian Institute of Sciences
  • Institut Teknologi Sepuluh Nopember
  • National Research and Innovation Agency
  • University of Indonesia
  • National University of Malaysia
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Asri Rizki YulianiIndonesian Institute of Sciences2
M. Faizal AmriIndonesian Institute of Sciences2
Dwi Esti KusumandariNational Research and Innovation Agency2
Muhammad Ilham RizqyawanNational Research and Innovation Agency2
Ahmad FudholiNational University of Malaysia1
Ridwan Arief SubektiUniversity of Indonesia1
Dalmasius Ganjar SubagioIndonesian Institute of Sciences1
Ahmad RajaniNational Research and Innovation Agency1
Hendri Maja SaputraIndonesian Institute of Sciences1
Estiko RijantoNational Research and Innovation Agency1
Latif RozaqiAffiliation unknown1
Edwar YazidIndonesian Institute of Sciences1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210212760, first harvested 21 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Low-Cost Multimodal Physiological Telemonitoring System through Internet of Things</dc:title><dc:creator>Kadek Heri Sanjaya</dc:creator><dc:creator>Asep Nugroho</dc:creator><dc:creator>Latif Rozaqie</dc:creator><dc:creator>Yukhi Mustaqim Kusuma Sya’Bana</dc:creator><dc:creator>Rizqi Andry Ardiansyah</dc:creator><dc:creator>Artha Ivonita Simbolon</dc:creator><dc:creator>Ulfah Nadiya</dc:creator><dc:creator>Dalna Nikita Ramdhani</dc:creator><dc:creator>Muhammad Akbar Maulana</dc:creator><dc:creator>Achmad Fachturrohman</dc:creator><dc:creator>Vyndi Myllazari</dc:creator><dc:creator>Bhetri Sonia Yolandari</dc:creator><dc:creator>Lolita Agastya</dc:creator><dc:subject>Internet of Things</dc:subject><dc:subject>COVID-19 pandemic</dc:subject><dc:subject>ECG sensor</dc:subject><dc:subject>body temperature sensor</dc:subject><dc:subject>pulse oximeter</dc:subject><dc:subject>cloud data transmission</dc:subject><dc:subject>microcontroller</dc:subject><dc:subject>low-cost medical device</dc:subject><dc:subject>healthcare worker safety</dc:subject><dc:subject>Wi-Fi data transmission</dc:subject><dc:description xml:lang="en">The objective of this study is to develop and test a patient telemonitoring system. This study was encouraged by the high number of health workers fatalities in Indonesia due to physical contact without proper protection. Based on the symptoms of COVID-19 it consists of electrocardiogram (ECG) sensors, body temperature sensors, respiratory rate sensors, and pulse oximeter. The physiological data were captured by the sensors and collected by a microcontroller then it sends the data to a cloud system so that health workers can access the data. The experiments were performed to test both the offline and online protocol to compare data sent via a direct connection and data sent via Wi-Fi. In the offline testing, there were several limitations observed such as the low sampling frequency of the ECG signals that reduce the fidelity of the signals. Such problems were also observed on respiratory rate data. Furthermore, the system is also very prone to subjects’ movement-related noise. The measurements of peripheral oxygen saturation (SpO2) and body temperature, on the other hand, have been detected the slight change up to 0.1% and 0.5oC respectively. In the online testing, the data transmission to the cloud is sent per 30 seconds so that morphologically the ECG signal data are not representative. The system requires a lot of improvements and future study should be directed to improve signals acquisition and processing while maintaining the concept of low-cost. Design improvement should also include a better attachment design to the human body as well as greater data transmission for the online system.</dc:description><dc:publisher>Indonesian Institute of Sciences</dc:publisher><dc:date>2021-08-31</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.14203/jet.v21.55-63</dc:identifier><dc:identifier>10.14203/jet.v21.55-63</dc:identifier><dc:source>Jurnal Elektronika dan Telekomunikasi; Vol 21 No 1 (2021); 55-63</dc:source><dc:source>1411-8289</dc:source><dc:source>2527-9955</dc:source><dc:language>en</dc:language><dc:relation>https://www.jurnalet.com/jet/article/download/413/353</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>