Screen-Printed Carbon Electrode Modified GNPs/ZnO For Electrochemical Biosensing

Jurnal Elektronika dan Telekomunikasi · Vol. 24 No. 1 (2024) · pp. 38–45

DOI
10.55981/jet.593
ISSN
1411-8289, 2527-9955
Published
2024-08-31
Publisher
Indonesian Institute of Sciences
Language
en
License
creativecommons.org/licenses/by-nc-sa/4.0/

Abstract

Screen-printed carbon electrodes (SPCEs) modified with graphene nanoplatelets (GNPs) and zinc oxide (ZnO) are widely used in electrochemical sensors due to their enhanced electrochemical properties and biocompatibility. Screen-printed carbon electrodes modified with Graphene nanoplatelets (GNPs) /Zinc oxide (ZnO) nanocomposite are described. Thus, in this study, GNPs/ZnO nanocomposite was synthesized, characterized, and applied to an electrochemical sensor. The formation of GNPs/ZnO nanocomposite was characterized by UV-Vis spectroscopy and scanning electron microscopy. Moreover, SPCE-GNPs/ZnO nanocomposite were characterized using cyclic voltammetry to optimize the concentration of nanocomposite. Then, the analytical performance of the sensor was studied by measuring methylparaben as an organic compound using differential pulse voltammetry (DPV) as a preliminary study before using it for biosensing. The result showed a significant improvement in electrocatalytic activity and reproducibility. The ratio of GNPs/ZnO nanocomposite with a concentration of 1 mg/mL produced the highest current response. Moreover, the detection of methylparaben showed high sensitivity with a limit of detection (LOD) around 9.7 μM, indicating high selectivity and good reproducibility of SPCE-GNPs/ZnO. Hence, the proposed sensor of SPCE-GNPs/ZnO displayed good performance, sensitivity, and reproducibility.

Keywords

Collaboration network of the authors

12 authors · 31 co-authorship links · 17 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Bandung Institute of Technology
  • Binus University
  • National Research and Innovation Agency
  • Indonesian Institute of Sciences
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Brian YuliartoBandung Institute of Technology1
Bambang SunendarBandung Institute of Technology1
Nugraha NugrahaBandung Institute of Technology1
Lia Amelia Tresna Wulan AsriBandung Institute of Technology1
Aminuddin DebatarajaBandung Institute of Technology1
Agustina Sus AndreaniNational Research and Innovation Agency1
Dedi MadaIndonesian Institute of Sciences1
Jonathan Edwards TelaumbanuaBinus University1
Richard Anthony LimBinus University1
Winda AstutiBinus University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210212760, first harvested 21 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Screen-Printed Carbon Electrode Modified GNPs/ZnO For Electrochemical Biosensing</dc:title><dc:creator>Atik Dwi Oktaviani</dc:creator><dc:creator>Robeth Viktoria Manurung</dc:creator><dc:subject>screen-printed carbon electrode</dc:subject><dc:subject>graphene nanoplatelets</dc:subject><dc:subject>zinc oxide</dc:subject><dc:subject>electrochemical biosensor</dc:subject><dc:subject>electrocatalytic activity</dc:subject><dc:subject>differential pulse voltammetry</dc:subject><dc:subject>detection limit</dc:subject><dc:description xml:lang="en">Screen-printed carbon electrodes (SPCEs) modified with graphene nanoplatelets (GNPs) and zinc oxide (ZnO) are widely used in electrochemical sensors due to their enhanced electrochemical properties and biocompatibility. Screen-printed carbon electrodes modified with Graphene nanoplatelets (GNPs) /Zinc oxide (ZnO) nanocomposite are described. Thus, in this study, GNPs/ZnO nanocomposite was synthesized, characterized, and applied to an electrochemical sensor. The formation of GNPs/ZnO nanocomposite was characterized by UV-Vis spectroscopy and scanning electron microscopy. Moreover, SPCE-GNPs/ZnO nanocomposite were characterized using cyclic voltammetry to optimize the concentration of nanocomposite. Then, the analytical performance of the sensor was studied by measuring methylparaben as an organic compound using differential pulse voltammetry (DPV) as a preliminary study before using it for biosensing. The result showed a significant improvement in electrocatalytic activity and reproducibility. The ratio of GNPs/ZnO nanocomposite with a concentration of 1 mg/mL produced the highest current response. Moreover, the detection of methylparaben showed high sensitivity with a limit of detection (LOD) around 9.7 μM, indicating high selectivity and good reproducibility of SPCE-GNPs/ZnO. Hence, the proposed sensor of SPCE-GNPs/ZnO displayed good performance, sensitivity, and reproducibility.</dc:description><dc:publisher>Indonesian Institute of Sciences</dc:publisher><dc:date>2024-08-31</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.55981/jet.593</dc:identifier><dc:identifier>10.55981/jet.593</dc:identifier><dc:source>Jurnal Elektronika dan Telekomunikasi; Vol 24 No 1 (2024); 38-45</dc:source><dc:source>1411-8289</dc:source><dc:source>2527-9955</dc:source><dc:language>en</dc:language><dc:relation>https://www.jurnalet.com/jet/article/download/593/458</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>