Melola Discovery

← Melola Discovery

Journal No SINTA rank

Analisis Perbandingan Kualitas Produk Amplikon Gen PMSA2 Antara Spesimen Spot Darah Kering dan Vena

JURNAL BIOLOGI PAPUA · Vol. 12 No. 1 (2020) · pp. 10–18

DOI
10.31957/jbp.949
ISSN
2503-0450, 2086-3314
Published
2020-03-05
Publisher
Jurusan Biologi FMIPA Universitas Cenderawasih
Language
eng

Abstract

This study is aimed to analyze the comparative quality of PMSA2 gene amplicon product stability from two different specimen sources, spot specimens of dried blood and venous blood, as well as selecting the best storage method for specimens of blood samples. This research uses descriptive laboratory research methods. The research began with the process of sample preparation for dried blood spot and venous blood, each using Whatman 903 paper and vacuum tubes containing EDTA, isolating genomic DNA using KIT Zymo Research, amplification of PMSA-2 genes with PCR, detection of PCR products through electrophoresis, measurement of DNA concentration and absorbance, and data analysis. The results of this study are expected to be a source of information about the advantages of two specimen storage methods for clinical blood samples, as well as providing a clear description of the quality of each specimen storage method based on the quality of its amplicon products. The results showed that a total of ten medical samples of dried blood spot and ten venous blood were isolated from the genomic DNA of ten and nine, respectively. PMSA2 gene amplicons detected were seven in venous blood and six in dried blood spot. Venous blood specimens have sensitivity in detecting PMSA genes in samples with the highest value of 554 ng / μL and purity of 2,007 (WB7), and concentration of 550.2 and highest purity of 2,076 (WB10). Venous blood storage techniques using categorized vacuum tubes are effective in the detection of PMSA2 genes and have time efficiency in the process. From these results it was also concluded that the comparison analysis of amplicon products between venous blood specimens was better, more stable and efficient than dry blood spot specimens, thus recommending storage of venous blood specimens using vacuum tubes as the best storage method of blood sample specimens.

Collaboration network of the authors

40 authors · 137 co-authorship links · 3 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Cenderawasih University
  • Kementerian Kesehatan Republik Indonesia
  • National Research and Innovation Agency
  • Universitas Halu Oleo
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Rosye H.R. TanjungCenderawasih University4
Mirna WidiyantiKementerian Kesehatan Republik Indonesia3
Antonius OktavianCenderawasih University3
Euniche R.P.F. RamandeyCenderawasih University2
Marsi Adi PurwadiCenderawasih University2
Hotma Martogi Lorensi HutapeaNational Research and Innovation Agency2
Yunita MirinoAffiliation unknown2
Eva FitrianaAffiliation unknown2
Maria Ludia SimonapendiCenderawasih University1
Suwito SuwitoCenderawasih University1
Leonardo Elisa AisoiCenderawasih University1
Paula Nancy LefaanCenderawasih University1
Evie Lilly WarikarCenderawasih University1
I Made BudiCenderawasih University1
Sammaria J. KarmaCenderawasih University1
Ziyadatun Ni’mahCenderawasih University1
John R. BisaiCenderawasih University1
Bruce H.R. MauriAffiliation unknown1
Marcelino Novryanto YonasCenderawasih University1
Leonard SiregarCenderawasih University1
Rosye H.R. TanjungCenderawasih University1
Indah W. TambunanCenderawasih University1
Alin S.D. YampyCenderawasih University1
Wulan N. AnwariCenderawasih University1
Chesiana ChesianaCenderawasih University1
Marlifon MeraniCenderawasih University1
Vanessa Y.A. BrabarCenderawasih University1
Sara D. LemaukCenderawasih University1
Urinsi PattaruCenderawasih University1
Dames KogoyaCenderawasih University1
Oktafianti A. NurafifahCenderawasih University1
Yuliance NawipaCenderawasih University1
Jovita L. KayameCenderawasih University1
Dewi AnggrainiUniversitas Halu Oleo1
Indra YoviAffiliation unknown1
Dodi SafariAffiliation unknown1
Nur Afrainin SyahAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://ejournal.uncen.ac.id/index.php/JBP/oai, first harvested 1 Nov 2026, last seen 15 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Analisis Perbandingan Kualitas Produk Amplikon  Gen PMSA2 Antara Spesimen Spot Darah Kering dan Vena</dc:title>
	<dc:creator>Mawardi, Arsyam</dc:creator>
	<dc:creator>Maury, Hendra K.</dc:creator>
	<dc:creator>Maladan, Yustinus</dc:creator>
	<dc:description xml:lang="en-US">This study is aimed to analyze the comparative quality of PMSA2 gene amplicon product stability from two different specimen sources, spot specimens of dried blood and venous blood, as well as selecting the best storage method for specimens of blood samples. This research uses descriptive laboratory research methods. The research began with the process of sample preparation for dried blood spot and venous blood, each using Whatman 903 paper and vacuum tubes containing EDTA, isolating genomic DNA using KIT Zymo Research, amplification of PMSA-2 genes with PCR, detection of PCR products through electrophoresis, measurement of DNA concentration and absorbance, and data analysis. The results of this study are expected to be a source of information about the advantages of two specimen storage methods for clinical blood samples, as well as providing a clear description of the quality of each specimen storage method based on the quality of its amplicon products. The results showed that a total of ten medical samples of dried blood spot and ten venous blood were isolated from the genomic DNA of ten and nine, respectively. PMSA2 gene amplicons detected were seven in venous blood and six in dried blood spot. Venous blood specimens have sensitivity in detecting PMSA genes in samples with the highest value of 554 ng / μL and purity of 2,007 (WB7), and concentration of 550.2 and highest purity of 2,076 (WB10). Venous blood storage techniques using categorized vacuum tubes are effective in the detection of PMSA2 genes and have time efficiency in the process. From these results it was also concluded that the comparison analysis of amplicon products between venous blood specimens was better, more stable and efficient than dry blood spot specimens, thus recommending storage of venous blood specimens using vacuum tubes as the best storage method of blood sample specimens.</dc:description>
	<dc:publisher xml:lang="en-US">Jurusan Biologi FMIPA Universitas Cenderawasih</dc:publisher>
	<dc:date>2020-03-05</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejournal.uncen.ac.id/index.php/JBP/article/view/949</dc:identifier>
	<dc:identifier>10.31957/jbp.949</dc:identifier>
	<dc:source xml:lang="en-US">JURNAL BIOLOGI PAPUA; Vol. 12 No. 1 (2020); 10-18</dc:source>
	<dc:source xml:lang="id-ID">Jurnal Biologi Papua; Vol 12 No 1 (2020); 10-18</dc:source>
	<dc:source>2503-0450</dc:source>
	<dc:source>2086-3314</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ejournal.uncen.ac.id/index.php/JBP/article/view/949/953</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 JURNAL BIOLOGI PAPUA</dc:rights>
</oai_dc:dc>