Melola Discovery

← Melola Discovery

Journal SINTA 3

OPTIMASI PEMBACAAN SUHU KAMERA TERMAL MENGGUNAKAN REGRESI LINIER

BAREKENG: Jurnal Ilmu Matematika dan Terapan · Vol. 15 No. 1 (2021) · pp. 127–136

DOI
10.30598/barekengvol15iss1pp127-136
ISSN
2615-3017, 1978-7227
Published
2021-03-01
Publisher
PATTIMURA UNIVERSITY
Language
eng

Abstract

Fever is one of the symptoms of a person with Covid-19. Body temperature must be checked e before entering crowded areas such as schools, offices, shops, and hospitals. It is a mandatory protocol that must be done. One of the tools that can be used to check body temperature is a thermal camera. Thermal cameras have the disadvantage of a high temperature reading error. This is because the thermal camera used has a low resolution. This study aims to reduce the value of the temperature reading error on the thermal camera using the linear regression method. The linear regression method is able to reduce the error rate of temperature readings by 5.27% at 36 ° C reading. The reduction in reading error also occurred by 5.27% at 37 ° C and 6.44% at 38 ° C. Based on the results obtained, this study shows that linear regression can be applied to thermal cameras and provides a decrease in the error rate of temperature readings on thermal cameras

Collaboration network of the authors

16 authors · 35 co-authorship links · 9 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Institut Teknologi Telkom Purwokerto
  • Institut Teknologi Telkom Surabaya
  • Politeknik Surabaya
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Anggun Fitrian IsnawatiInstitut Teknologi Telkom Purwokerto2
Helmy WidyantaraInstitut Teknologi Telkom Surabaya2
Chandra AgustinahInstitut Teknologi Telkom Purwokerto2
Risa Farid CrisiantiInstitut Teknologi Telkom Purwokerto2
Prieska MarinaInstitut Teknologi Telkom Purwokerto1
Dimas AdiputraInstitut Teknologi Telkom Surabaya1
Isa HafidzInstitut Teknologi Telkom Surabaya1
Billy MontolaluInstitut Teknologi Telkom Surabaya1
Wahyu Andy PrastyabudiInstitut Teknologi Telkom Surabaya1
Brayan RaynaldiInstitut Teknologi Telkom Purwokerto1
Ristanti AkseptoriPoliteknik Surabaya1
Ubaidilah UmarInstitut Teknologi Telkom Surabaya1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://ojs3.unpatti.ac.id/index.php/barekeng/oai, first harvested 5 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">OPTIMASI PEMBACAAN SUHU KAMERA TERMAL MENGGUNAKAN REGRESI LINIER</dc:title>
	<dc:creator>Purnama, Sevia Indah</dc:creator>
	<dc:creator>Hikmah, Irmayatul</dc:creator>
	<dc:creator>Afandi, Mas Aly</dc:creator>
	<dc:creator>Mulyani, Elsa Sri</dc:creator>
	<dc:description xml:lang="en-US">Fever is one of the symptoms of a person with Covid-19. Body temperature must be checked e before entering crowded areas such as schools, offices, shops, and hospitals. It is a mandatory protocol that must be done. One of the tools that can be used to check body temperature is a thermal camera. Thermal cameras have the disadvantage of a high temperature reading error. This is because the thermal camera used has a low resolution. This study aims to reduce the value of the temperature reading error on the thermal camera using the linear regression method. The linear regression method is able to reduce the error rate of temperature readings by 5.27% at 36 ° C reading. The reduction in reading error also occurred by 5.27% at 37 ° C and 6.44% at 38 ° C. Based on the results obtained, this study shows that linear regression can be applied to thermal cameras and provides a decrease in the error rate of temperature readings on thermal cameras</dc:description>
	<dc:publisher xml:lang="en-US">PATTIMURA UNIVERSITY</dc:publisher>
	<dc:date>2021-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs3.unpatti.ac.id/index.php/barekeng/article/view/3029</dc:identifier>
	<dc:identifier>10.30598/barekengvol15iss1pp127-136</dc:identifier>
	<dc:source xml:lang="en-US">BAREKENG: Jurnal Ilmu Matematika dan Terapan; Vol 15 No 1 (2021): BAREKENG: Jurnal Ilmu Matematika dan Terapan; 127-136</dc:source>
	<dc:source>2615-3017</dc:source>
	<dc:source>1978-7227</dc:source>
	<dc:source>10.30598/barekengvol15iss1year2021</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs3.unpatti.ac.id/index.php/barekeng/article/view/3029/2703</dc:relation>
</oai_dc:dc>