Melola Discovery

← Melola Discovery

Open access Journal SINTA 3

1/3 SIMPSON’S RULE FOR ANALYSIS OF STRUCTURE DYNAMIC RESPONSE DUE TO EARTHQUAKE LOAD

BAREKENG: Jurnal Ilmu Matematika dan Terapan · Vol. 17 No. 2 (2023) · pp. 0641–0648

DOI
10.30598/barekengvol17iss2pp0641-0648
ISSN
2615-3017, 1978-7227
Published
2023-06-11
Publisher
PATTIMURA UNIVERSITY
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

In structural analysis, many calculations are encountered which are very complex, making it difficult to do with exact mathematical calculations. For easier analysis, numerical methods are needed to simplify the calculations. Complex building structures such as towers, multi-storey structures and other buildings, are idealized for simplification into a single degree of freedom system (SDOF), assuming that the dynamic response of structures due to earthquake loads is horizontal. The analysis of this model is correlated with numerical analysis, so it can be completed quickly. The numerical method used in this study is the 1/3 Simpson Integral Method, because this method is suitable for calculating dynamic structural responses such as structural displacement responses. The analysis procedure begins by entering the external forces on the structural system and calculating the resulting response value. The analysis can be repeated for a variety of different parameters, such as the mass of the structure, the dumping ratio and the stiffness of the structure. Structural response is calculated by sinusoidal dynamic load type for damped and undamped systems. The results of this study conclude that the relationship between the mass of the structure, the damping of the structure and the stiffness of the structure with the displacement of the structure has an inverse relationship, where with high mass, high damping and high stiffness, it can reduce the structure displacement.

Collaboration network of the authors

5 authors · 6 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universitas Putra Indonesia "YPTK"
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Radius PrawiroUniversitas Putra Indonesia "YPTK"1
Nanda NandaUniversitas Putra Indonesia "YPTK"1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://ojs3.unpatti.ac.id/index.php/barekeng/oai, first harvested 5 Nov 2026, last seen 15 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">1/3 SIMPSON’S RULE FOR ANALYSIS OF STRUCTURE DYNAMIC RESPONSE DUE TO EARTHQUAKE LOAD</dc:title>
	<dc:creator>Imani, Rafki</dc:creator>
	<dc:creator>Nasmirayanti, Rita</dc:creator>
	<dc:creator>Sahputra, Deded Eka</dc:creator>
	<dc:description xml:lang="en-US">In structural analysis, many calculations are encountered which are very complex, making it difficult to do with exact mathematical calculations. For easier analysis, numerical methods are needed to simplify the calculations. Complex building structures such as towers, multi-storey structures and other buildings, are idealized for simplification into a single degree of freedom system (SDOF), assuming that the dynamic response of structures due to earthquake loads is horizontal. The analysis of this model is correlated with numerical analysis, so it can be completed quickly. The numerical method used in this study is the 1/3 Simpson Integral Method, because this method is suitable for calculating dynamic structural responses such as structural displacement responses. The analysis procedure begins by entering the external forces on the structural system and calculating the resulting response value. The analysis can be repeated for a variety of different parameters, such as the mass of the structure, the dumping ratio and the stiffness of the structure. Structural response is calculated by sinusoidal dynamic load type for damped and undamped systems. The results of this study conclude that the relationship between the mass of the structure, the damping of the structure and the stiffness of the structure with the displacement of the structure has an inverse relationship, where with high mass, high damping and high stiffness, it can reduce the structure displacement.</dc:description>
	<dc:publisher xml:lang="en-US">PATTIMURA UNIVERSITY</dc:publisher>
	<dc:date>2023-06-11</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs3.unpatti.ac.id/index.php/barekeng/article/view/6845</dc:identifier>
	<dc:identifier>10.30598/barekengvol17iss2pp0641-0648</dc:identifier>
	<dc:source xml:lang="en-US">BAREKENG: Jurnal Ilmu Matematika dan Terapan; Vol 17 No 2 (2023): BAREKENG: Journal of Mathematics and Its Applications; 0641-0648</dc:source>
	<dc:source>2615-3017</dc:source>
	<dc:source>1978-7227</dc:source>
	<dc:source>10.30598/barekengvol17iss2year2023</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs3.unpatti.ac.id/index.php/barekeng/article/view/6845/5925</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Rafki Imani, Rita Nasmirayanti, Deded Eka Sahputra</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>