Melola Discovery

← Melola Discovery

Open access Journal SINTA 3

NUMERICAL ANALYSIS OF BLOOD VESSEL CONSTRICTION DUE TO ATHEROSCLEROSIS DISEASE USING FINITE VOLUME METHOD

BAREKENG: Jurnal Ilmu Matematika dan Terapan · Vol. 19 No. 4 (2025) · pp. 2661–2678

DOI
10.30598/barekengvol19iss4pp2661-2678
ISSN
2615-3017, 1978-7227
Published
2025-09-01
Publisher
PATTIMURA UNIVERSITY
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Atherosclerosis is a leading cause of coronary heart disease. This study analyses how elliptically shaped stenoses alter blood-flow velocity in coronary arteries. The governing equations are discretised with the finite-volume method, coupling pressure and velocity through the SIMPLE (Semi-Implicit Method for Pressure-Linked Equations) algorithm and accelerating convergence with the Successive Over-Relaxation (SOR) technique. A weighted Gauss–Seidel iteration whose over-relaxation factor ( in this work) damps low-frequency error modes, cutting the number of iterations needed for residuals to fall below 10⁻⁴ by roughly 40 % compared with the standard Gauss–Seidel scheme. Simulations of 30 %, 50 %, and 70 % constrictions were carried out in MATLAB R2013a and ANSYS Fluent. Quantitative and qualitative cross-validation of the two software packages confirmed consistent velocity and pressure fields, though minor discrepancies arose from differing numerical schemes and model assumptions, underscoring the need for experimental verification. The highest centre-line velocity occurred at 70 % stenosis—0.72075 m/s in MATLAB versus 0.90 m/s in Fluent—while the lowest was recorded at 30 %. Velocity–pressure profiles showed that increasing inlet velocity or degree of narrowing elevates velocity but decreases pressure, with the largest drop (11492.4 Pa in MATLAB; 11747.32 Pa in Fluent) again at 70% stenosis. Study limitations include modelling blood as a Newtonian fluid and idealising arterial geometry; future work should incorporate non-Newtonian rheology and patient-specific shapes to enhance physiological accuracy.

Collaboration network of the authors

30 authors · 98 co-authorship links · 8 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universitas Jember
  • Universitas Pendidikan Ganesha
  • Universitas PGRI Argopuro Jember
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Dafik DafikUniversitas Jember8
Arika Indah KristianaUniversitas Jember7
Susi SetiawaniUniversitas Jember5
Aji Mansur SantosoUniversitas Jember3
Alfiani Dyah PratiwiUniversitas Jember2
Nira Nityasa SarantaUniversitas Jember2
Antonius CahyaPrihandokoAffiliation unknown2
Putri Nur AmalinaUniversitas Jember1
Deddy SetyawanUniversitas Jember1
Anis Nur AfniUniversitas Jember1
Ermita Rizki AlbirriUniversitas Jember1
Muslihatul AimaUniversitas Jember1
Girlyas Rasta YuntaUniversitas Jember1
RM PrihandiniAffiliation unknown1
AC PrihandokoAffiliation unknown1
Indi Izzah MakhfudlohUniversitas Jember1
Maimunah RahmadaniUniversitas Jember1
I Nengah SupartaUniversitas Pendidikan Ganesha1
Muhammad Ilham Nurfaizi AnnadhifiUniversitas Jember1
Ika Hesti AgustinUniversitas Jember1
Fitriyatul MardiyahUniversitas Jember1
Excelsa Suli Wildhatul JannahUniversitas Jember1
Marsidi MarsidiUniversitas PGRI Argopuro Jember1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://ojs3.unpatti.ac.id/index.php/barekeng/oai, first harvested 5 Nov 2026, last seen 8 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">NUMERICAL ANALYSIS OF BLOOD VESSEL CONSTRICTION DUE TO ATHEROSCLEROSIS DISEASE USING FINITE VOLUME METHOD</dc:title>
	<dc:creator>Fatahillah, Arif</dc:creator>
	<dc:creator>Mubarokah, Umi</dc:creator>
	<dc:creator>Megahnia Prihandini, Rafiantika</dc:creator>
	<dc:creator>Wihardjo, Edy</dc:creator>
	<dc:creator>Adawiyah, Robiatul</dc:creator>
	<dc:creator>Hussen, Saddam</dc:creator>
	<dc:creator>Monalisa, Lioni Anka</dc:creator>
	<dc:description xml:lang="en-US">Atherosclerosis is a leading cause of coronary heart disease. This study analyses how elliptically shaped stenoses alter blood-flow velocity in coronary arteries. The governing equations are discretised with the finite-volume method, coupling pressure and velocity through the SIMPLE (Semi-Implicit Method for Pressure-Linked Equations) algorithm and accelerating convergence with the Successive Over-Relaxation (SOR) technique. A weighted Gauss–Seidel iteration whose over-relaxation factor ( &amp;nbsp;in this work) damps low-frequency error modes, cutting the number of iterations needed for residuals to fall below 10⁻⁴ by roughly 40 % compared with the standard Gauss–Seidel scheme. Simulations of 30 %, 50 %, and 70 % constrictions were carried out in MATLAB R2013a and ANSYS Fluent. Quantitative and qualitative cross-validation of the two software packages confirmed consistent velocity and pressure fields, though minor discrepancies arose from differing numerical schemes and model assumptions, underscoring the need for experimental verification. The highest centre-line velocity occurred at 70 % stenosis—0.72075 m/s in MATLAB versus 0.90 m/s in Fluent—while the lowest was recorded at 30 %. Velocity–pressure profiles showed that increasing inlet velocity or degree of narrowing elevates velocity but decreases pressure, with the largest drop (11492.4 Pa in MATLAB; 11747.32 Pa in Fluent) again at 70% stenosis. Study limitations include modelling blood as a Newtonian fluid and idealising arterial geometry; future work should incorporate non-Newtonian rheology and patient-specific shapes to enhance physiological accuracy.</dc:description>
	<dc:publisher xml:lang="en-US">PATTIMURA UNIVERSITY</dc:publisher>
	<dc:date>2025-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs3.unpatti.ac.id/index.php/barekeng/article/view/17649</dc:identifier>
	<dc:identifier>10.30598/barekengvol19iss4pp2661-2678</dc:identifier>
	<dc:source xml:lang="en-US">BAREKENG: Jurnal Ilmu Matematika dan Terapan; Vol 19 No 4 (2025): BAREKENG: Journal of Mathematics and Its Application; 2661-2678</dc:source>
	<dc:source>2615-3017</dc:source>
	<dc:source>1978-7227</dc:source>
	<dc:source>10.30598/barekengvol19iss4year2025</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs3.unpatti.ac.id/index.php/barekeng/article/view/17649/11134</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Arif Fatahillah, Umi Mubarokah, Rafiantika Megahnia Prihandini, Edy Wihardjo, Robiatul Adawiyah, Saddam Hussen, Lioni Anka Monalisa</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>