Abstract

Connecting the transformer to the network may incur inrush current, which is significantly higher than the rated current of the transformer. The main cause of this phenomenon lies in the nonlinearity of the magnetic circuit. The value of the inrush current depends of the time moment of the energization and the residual magnetism in the transformer core. While connecting, the operating point of the magnetization characteristic can be found deep in the saturation region resulting in occurrence of large transformer currents that can trigger the transformer protection. Tripping of protection immediately after the transformer energization raises doubts about the transformer health. Inrush current can cause a number of other disadvantages such as the negative impact on other transformers connected on the same busbar; the increase of the transformer noise due to the large current value, the increase of the voltage drops in the network. The paper presents a simulation of the 300 MVA transformer energization using the MATLAB/Simulink software.

Collaboration network of the authors

16 authors · 37 co-authorship links · 12 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Osijek
  • Universiti Teknikal Malaysia Melaka
  • Fond za zaštitu okoliša i energetsku učinkovitost
  • Universitas Ahmad Dahlan
  • Regional Energy Agency
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Goran KneževićUniversity of Osijek6
Ljubomir MajdandžićFond za zaštitu okoliša i energetsku učinkovitost6
Dragan MlakićAffiliation unknown5
Zoran BausUniversity of Osijek4
Marko VukobratovićUniversity of Osijek2
Tole SutiknoUniversitas Ahmad Dahlan2
Mohd Hatta JopriUniversiti Teknikal Malaysia Melaka2
Mustafa ManapUniversiti Teknikal Malaysia Melaka2
Goran SlipacAffiliation unknown2
Jurica PerkoRegional Energy Agency1
Abdul Rahim AbdullahUniversiti Teknikal Malaysia Melaka1
Aleksandr SkamyinAffiliation unknown1
Rony KarimAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 8 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Transient Phenomena during the Three-Phase 300MVA Transformer Energization on the Transmission Network</dc:title><dc:creator>Alibašić, Emir</dc:creator><dc:creator>Marić, Predrag</dc:creator><dc:creator>Nikolovski, Srete N</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;Connecting the transformer to the network may incur inrush current, which is significantly higher than the rated current of the transformer. The main cause of this phenomenon lies in the nonlinearity of the magnetic circuit. The value of the inrush current depends of the time moment of the energization and the residual magnetism in the transformer core. While connecting, the operating point of the magnetization characteristic can be found deep in the saturation region resulting in occurrence of large transformer currents that can trigger the transformer protection. Tripping of protection immediately after the transformer energization raises doubts about the transformer health. Inrush current can cause a number of other disadvantages such as the negative impact on other transformers connected on the same busbar; the increase of the transformer noise due to the large current value, the increase of the voltage drops in the network. The paper presents a simulation of the 300 MVA transformer energization using the MATLAB/Simulink software.&amp;lt;/p&amp;gt;&amp;lt;p&amp;gt; &amp;lt;/p&amp;gt;&amp;lt;p&amp;gt; &amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2016-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v6i6.11406</dc:identifier><dc:identifier>10.11591/ijece.v6i6.11406</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 6 No 6 (2016); 2499</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://www.iaescore.com/journals/index.php/IJECE/article/viewFile/5861/5519</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc-nd/4.0</dc:rights></oai_dc:dc>