Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Current Controller Based Power Management Strategy for Interfacing DG Units to Micro Grid

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 7 No. 5 (2017)

DOI
10.11591/ijece.v7i5.pp2300-2308
ISSN
2088-8708, 2088-8708
Published
2017-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

This paper proposes a power management strategy of parallel inveters based system, to enhance the power generation capacity of the existing system with distributed energy sources one has to choose DG source based inverter connected in parallel with the existing system.Two DG sources PV, Fuel cells feeds the DC voltage to two parallel inverters connected to the grid. Fixed band hysteresis current control with Instantaneous p-q power theory is adopted to create an artificial environment. Two parallel inverters are able to deliver the harvested power from PV, FC to grid and able to balance the load Without communication between parallel inverters this controller having the capability of load following, the harmonic components of currents at output of inverter are also very low; this will automatically reduces the circulating currents between parallel inverters. Simulation studies are carried out to investigate the results of PV, FC systems connected to the utility grid.

Collaboration network of the authors

15 authors · 20 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Jawaharlal Nehru Technological University Anantapur
  • Acharya Nagarjuna University
  • R.V. College of Engineering
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Syed SurayaJawaharlal Nehru Technological University Anantapur2
Yaramasu Suri BabuAcharya Nagarjuna University2
P. Bharat KumarAffiliation unknown1
M. NagaiahAcharya Nagarjuna University1
Mallempati Sunil KumarJawaharlal Nehru Technological University Anantapur1
G. SatheeshJawaharlal Nehru Technological University Anantapur1
Gopisetti SateeshAffiliation unknown1
Meesala VenkateswarluJawaharlal Nehru Technological University Anantapur1
P. KumarJawaharlal Nehru Technological University Anantapur1
Yannam Ravi SankarAcharya Nagarjuna University1
Elluru RamakrishnaAffiliation unknown1
Gadhamappagari JayakrishnaAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Current Controller Based Power Management Strategy for Interfacing DG Units to Micro Grid</dc:title><dc:creator>Chaitanya, N.</dc:creator><dc:creator>Sujatha, P.</dc:creator><dc:creator>Sekhar, K. Chandra</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;This paper proposes a power management strategy of parallel inveters based system, to enhance the power generation capacity of the existing system with distributed energy sources one has to choose DG source based inverter connected in parallel with the existing system.Two DG sources PV, Fuel cells feeds the DC voltage to two parallel inverters connected to the grid. Fixed band hysteresis current control with Instantaneous p-q power theory is adopted to create an artificial environment. Two parallel inverters are able to deliver the harvested power from PV, FC to grid and able to balance the load Without communication between parallel inverters this controller having the capability of load following, the harmonic components of currents at output of inverter are also very low; this will automatically reduces the circulating currents between parallel inverters. Simulation studies are carried out to investigate the results of PV, FC systems connected to the utility grid.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2017-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v7i5.pp2300-2308</dc:identifier><dc:identifier>10.11591/ijece.v7i5.pp2300-2308</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 7 No 5 (2017); 2300</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/8180/6902</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>