Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Non-contact Heart Rate Monitoring Analysis from Various Distances with different Face Regions

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 7 No. 6 (2017)

DOI
10.11591/ijece.v7i6.pp3030-3036
ISSN
2088-8708, 2088-8708
Published
2017-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

Heart rate (HR) is one of vital biomedical signals for medical diagnosis. Previously, conventional camera is proven to be able to detect small changes in the skin due to the cardiac activity and can be used to measure the HR. However, most of the previous systems operate on near distance mode with a single face patch, thus the feasibility of the remote heart rate for various distances remains vague. This paper tackles this issue by analyzing an optimal framework that capable to works under the mentioned issues. Initially, plausible face landmarks are estimated by employing cascaded of regression mechanism. Next, the region of interest (ROI) was constructed from the landmarks in a face location where non rigid motion is minimal. From the ROI, temporal photoplethysmograph (PPG) signal is calculated based on the average green pixels intensity and environmental illumination is separated using Independent Component Analysis (ICA) filter. Eventually, the PPG signal is further processed using series of temporal filter to exclude frequencies outside the range of interest prior to estimate the HR. As a conclusion, the HR can be detected up to 5 meters range with 94% accuracy using lower part of face region.

Collaboration network of the authors

15 authors · 52 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Tun Hussein Onn University of Malaysia
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Syadia Nabilah Mohd SafuanTun Hussein Onn University of Malaysia5
Mohd Norzali Haji MohdTun Hussein Onn University of Malaysia4
Nor Surayahani SurianiTun Hussein Onn University of Malaysia4
Cham Ying KitTun Hussein Onn University of Malaysia3
Jacqueline Ang Jie YiTun Hussein Onn University of Malaysia3
Nicholas Tan Chun ShengTun Hussein Onn University of Malaysia3
Md Nor Ramdon BaharomTun Hussein Onn University of Malaysia3
Muhamad Fikri Shahkhirin BirahimTun Hussein Onn University of Malaysia3
Luqman Nol HakimTun Hussein Onn University of Malaysia3
Muhammad Fuad bin KassimTun Hussein Onn University of Malaysia2
Suhaila SariTun Hussein Onn University of Malaysia2

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 15 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Non-contact Heart Rate Monitoring Analysis from Various Distances with different Face Regions</dc:title><dc:creator>Ibrahim, Norwahidah</dc:creator><dc:creator>Tomari, Razali</dc:creator><dc:creator>Wan Zakaria, Wan Nurshazwani</dc:creator><dc:creator>Othman, Nurmiza</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span&amp;gt;Heart rate (HR) is one of vital biomedical signals for medical diagnosis. Previously, conventional camera is proven to be able to detect small changes in the skin due to the cardiac activity and can be used to measure the HR. However, most of the previous systems operate on near distance mode with a single face patch, thus the feasibility of the remote heart rate for various distances remains vague. This paper tackles this issue by analyzing an optimal framework that capable to works under the mentioned issues. Initially, plausible face landmarks are estimated by employing cascaded of regression mechanism. Next, the region of interest (ROI) was constructed from the landmarks in a face location where non rigid motion is minimal. From the ROI, temporal photoplethysmograph (PPG) signal is calculated based on the average green pixels intensity and environmental illumination is separated using Independent Component Analysis (ICA) filter. Eventually, the PPG signal is further processed using series of temporal filter to exclude frequencies outside the range of interest prior to estimate the HR. As a conclusion, the HR can be detected up to 5 meters range with 94% accuracy using lower part of face region.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2017-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v7i6.pp3030-3036</dc:identifier><dc:identifier>10.11591/ijece.v7i6.pp3030-3036</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 7 No 6 (2017); 3030</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/8671/7267</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>