Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

A novel integrated dual microneedle-microfluidic impedance flow cytometry for cells detection in suspensions

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 7 No. 3 (2017)

DOI
10.11591/ijece.v7i3.pp1513-1521
ISSN
2088-8708, 2088-8708
Published
2017-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

In this study, a new, simple and cost-effective impedance detection of yeast cell concentration by using a novel integrated dual microneedle-microfluidic impedance flow cytometry was introduced. The reported method for impedance flow cytometry detection utilizes embedded electrode and probe in the microfluidic device to perform measurement of electrical impedance when a presence of cells at sensing area. Nonetheless, this method requires costly and complicatedly fabrication process of electrode. Furthermore, to reuse the fabricated electrode, it also requires intensive and tedious cleaning process. Due to that, a dual microneedle integrated at the half height of the microchannel for cell detection as well as for electrical measurement was demonstrated. A commercial available Tungsten needle was utilized as a dual microneedle. The microneedle was easy to be removed from the disposable PDMS microchannel and can be reused with the simple cleaning process, such as washed by using ultrasonic cleaning. Although this device was low cost, it preserves the core functionality of the sensor, which is capable of detecting the passing cells at sensing area. Therefore, this device is suitable for low cost medical and food safety screening and testing process in developing countries.

Collaboration network of the authors

7 authors · 12 co-authorship links · 6 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Technology Malaysia
  • Nagoya University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nurul Bahiah Mohd NoorUniversity of Technology Malaysia1
Nur Fatien Najwa Mohamad NarjiUniversity of Technology Malaysia1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>A novel integrated dual microneedle-microfluidic impedance flow cytometry for cells detection in suspensions</dc:title><dc:creator>Mansor, Muhammad Asraf</dc:creator><dc:creator>Takeuchi, Masaru</dc:creator><dc:creator>Nakajima, Masahiro</dc:creator><dc:creator>Hasegawa, Yasuhisa</dc:creator><dc:creator>Ahmad, Mohd Ridzuan</dc:creator><dc:description>&lt;jats:p&gt;In this study, a new, simple and cost-effective impedance detection of yeast cell concentration by using a novel integrated dual microneedle-microfluidic impedance flow cytometry was introduced. The reported method for impedance flow cytometry detection utilizes embedded electrode and probe in the microfluidic device to perform measurement of electrical impedance when a presence of cells at sensing area. Nonetheless, this method requires costly and complicatedly fabrication process of electrode. Furthermore, to reuse the fabricated electrode, it also requires intensive and tedious cleaning process. Due to that, a dual microneedle integrated at the half height of the microchannel for cell detection as well as for electrical measurement was demonstrated. A commercial available Tungsten needle was utilized as a dual microneedle. The microneedle was easy to be removed from the disposable PDMS microchannel and can be reused with the simple cleaning process, such as washed by using ultrasonic cleaning. Although this device was low cost, it preserves the core functionality of the sensor, which is capable of detecting the passing cells at sensing area. Therefore, this device is suitable for low cost medical and food safety screening and testing process in developing countries.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2017-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v7i3.pp1513-1521</dc:identifier><dc:identifier>10.11591/ijece.v7i3.pp1513-1521</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 7 No 3 (2017); 1513</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/7517/6568</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>