Abstract

The loss of anterior teeth has a significant impact on masticatory function and facial aesthetics, making dental implants a widely used rehabilitative solution. The success of implants is greatly influenced by geometric design, particularly the diameter of the fixture, which plays a role in distributing load. This study aims to analyze the influence of variations in implant diameter on stress distribution, strain, and safety factor in the screw and abutment areas using a three-dimensional Finite Element Analysis (FEA) approach. Three implant models with fixture diameters of 3.75 mm, 4.00 mm, and 5.00 mm were simulated using a vertical physiological load of 130.5 ± 73.6 N, assuming Ti-6Al-4V material and orthotropic properties of the mandibular bone. The results showed that Model 2 (4.00 mm diameter) had the most balanced stress distribution and the highest safety factor value at the abutment (12.251), while Model 3 exhibited the lowest stress and strain at the screw. Model 1 had the lowest biomechanical performance with the highest stress and strain and the lowest abutment safety factor (10.611). It can be concluded that variations in fixture diameter significantly affect the mechanical performance of the implant system, and a diameter of 4.00 mm is recommended as the most optimal design to support long-term strength and stability.

Keywords

Collaboration network of the authors

40 authors · 152 co-authorship links · 1 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Cenderawasih University
  • State University of Semarang
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Rahmat Doni WidodoAffiliation unknown10
J. JamariAffiliation unknown10
DhiaulhaqueAffiliation unknown10
Mohd Syahmi JamaludinAffiliation unknown7
Khoirul HudaCenderawasih University6
Muhammad KhumaediAffiliation unknown4
Febri Budi DarsonoAffiliation unknown4
Fatkhu AmanullohAffiliation unknown4
Dzikra Adi PratamaAffiliation unknown4
Septian Eko CahyantoAffiliation unknown3
Wirawan SumbodoAffiliation unknown2
Deni Fajar FitriyanaAffiliation unknown2
Rifky IsmailAffiliation unknown2
Muhamad Reza Wahyu PrasetyoAffiliation unknown2
Tegar Oki PrasdikaAffiliation unknown2
Fadhil Putra RamadhanAffiliation unknown2
Kaleb PriyantoAffiliation unknown2
Rachael AndikaAffiliation unknown2
Andrean Rachman RizaldyAffiliation unknown2
Beni Aji SubektiAffiliation unknown2
Muhammad Iqbal RamadhaniAffiliation unknown2
Tri Indah WinarniAffiliation unknown2
Hasyid Ahmad WicaksonoAffiliation unknown2
Khoirudin FathoniState University of Semarang1
AbdurrahmanAffiliation unknown1
MUHAMMAD NUR FAIZINAffiliation unknown1
Atta Putra HarjantoAffiliation unknown1
R. Imanu Danar HerunandiAffiliation unknown1
R. Ambar Kuntoro Mursit GendroyonoAffiliation unknown1
Nugroho Fajar SusantoAffiliation unknown1
Muhammad Wifaqurrokhman AbdissalamAffiliation unknown1
Ari Dwi Nur Indriawan MusyonoAffiliation unknown1
Heri YudionoAffiliation unknown1
Imam Fitrah HadiAffiliation unknown1
Prastiyo prasAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/JPTM/oai, first harvested 5 Nov 2026, last seen 8 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">THE EFFECT OF IMPLANT DIAMETER ON STRESS, STRAIN, AND SAFETY FACTOR IN SCREWS AND ABUTMENTS BASED ON FEA</dc:title>
	<dc:creator xml:lang="en">gunagung syahrul nizam sulkan</dc:creator>
	<dc:creator xml:lang="en">Kriswanto</dc:creator>
	<dc:creator xml:lang="en">Ruben Bayu Kristiawan</dc:creator>
	<dc:creator xml:lang="en">Jamari</dc:creator>
	<dc:creator xml:lang="en">Athanasius Priharyoto Bayuseno</dc:creator>
	<dc:subject xml:lang="en">von mises</dc:subject>
	<dc:subject xml:lang="en">safety factor</dc:subject>
	<dc:subject xml:lang="en">finite element analisys</dc:subject>
	<dc:subject xml:lang="en">implant dental</dc:subject>
	<dc:description xml:lang="en">The loss of anterior teeth has a significant impact on masticatory function and facial aesthetics, making dental implants a widely used rehabilitative solution. The success of implants is greatly influenced by geometric design, particularly the diameter of the fixture, which plays a role in distributing load. This study aims to analyze the influence of variations in implant diameter on stress distribution, strain, and safety factor in the screw and abutment areas using a three-dimensional Finite Element Analysis (FEA) approach. Three implant models with fixture diameters of 3.75 mm, 4.00 mm, and 5.00 mm were simulated using a vertical physiological load of 130.5 ± 73.6 N, assuming Ti-6Al-4V material and orthotropic properties of the mandibular bone. The results showed that Model 2 (4.00 mm diameter) had the most balanced stress distribution and the highest safety factor value at the abutment (12.251), while Model 3 exhibited the lowest stress and strain at the screw. Model 1 had the lowest biomechanical performance with the highest stress and strain and the lowest abutment safety factor (10.611). It can be concluded that variations in fixture diameter significantly affect the mechanical performance of the implant system, and a diameter of 4.00 mm is recommended as the most optimal design to support long-term strength and stability.</dc:description>
	<dc:publisher xml:lang="en">Universitas Negeri Semarang</dc:publisher>
	<dc:date>2026-08-10</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unnes.ac.id/journals/JPTM/article/view/29461</dc:identifier>
	<dc:identifier>10.15294/jptm.v26i01.29461</dc:identifier>
	<dc:source xml:lang="en">Jurnal Pendidikan Teknik Mesin; Vol. 26 No. 01 (2026): June 2026 "Special issues for finite element analysis"; 1 - 10</dc:source>
	<dc:source>2503-1759</dc:source>
	<dc:source>2503-1759</dc:source>
	<dc:source>10.15294/jptm.v26i01</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.unnes.ac.id/journals/JPTM/article/view/29461/11027</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2026 Jurnal Pendidikan Teknik Mesin</dc:rights>
</oai_dc:dc>