Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

New Dead-Time Compensation Method of Power Inverter using Carrier Based Sinusoidal Pulse-Width Modulation

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 8 No. 6 (2018)

DOI
10.11591/ijece.v8i6.pp4880-4891
ISSN
2088-8708, 2088-8708
Published
2018-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

A new dead-time compensation method of power inverter circuits is suggested and presented in this paper. The proposed method utilizes carrier based sinusoidal pulse width modulation technique to produce driving signals of the inverter power switches with dead-time correction capability. The proposed method able to eliminate dead-time effects such as reducing the waveform distortion of the inverter output current, and increasing the fundamental component amplitude of output current. An analysis of the proposed method is presented. Some computer simulations were carried out to investigate the principle operation, and to test performance of the new method. The developed method was validated through experimental test of H-bridge voltage source inverter circuits. The data obtained from the computer simulation and prototype experiments have confirmed that that the proposed method worked well compensating the dead-time in the voltage source power inverter circuits.

Collaboration network of the authors

20 authors · 52 co-authorship links · 14 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Jenderal Soedirman University
  • Tun Hussein Onn University of Malaysia
  • Shizuoka University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Winasis WinasisJenderal Soedirman University6
Hari SiswantoroJenderal Soedirman University4
Hari PrasetijoJenderal Soedirman University4
Priswanto PriswantoJenderal Soedirman University3
Amran AmranJenderal Soedirman University3
Suroso SurosoAffiliation unknown2
Abdullah Nur AzizJenderal Soedirman University2
Wahyu Mulyo UtomoTun Hussein Onn University of Malaysia2
Afarulrazi Abu BakarTun Hussein Onn University of Malaysia2
Winasis WinasisAffiliation unknown1
Sholikhah SholikhahJenderal Soedirman University1
Retno SupriyantiJenderal Soedirman University1
Azis Wisnu Widhi NugrahaJenderal Soedirman University1
Hesti SusilawatiJenderal Soedirman University1
Eko Murdyantoro AmJenderal Soedirman University1
Agung MubyartoJenderal Soedirman University1
Arief Wisnu WardhanaJenderal Soedirman University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>New Dead-Time Compensation Method of Power Inverter using Carrier Based Sinusoidal Pulse-Width Modulation</dc:title><dc:creator>Suroso, Suroso</dc:creator><dc:creator>Nugroho, Daru Tri</dc:creator><dc:creator>Noguchi, Toshihiko</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;A new dead-time compensation method of power inverter circuits is suggested and presented in this paper. The proposed method utilizes carrier based sinusoidal pulse width modulation technique to produce driving signals of the inverter power switches with dead-time correction capability. The proposed method able to eliminate dead-time effects such as reducing the waveform distortion of the inverter output current, and increasing the fundamental component amplitude of output current. An analysis of the proposed method is presented. Some computer simulations were carried out to investigate the principle operation, and to test performance of the new method. The developed method was validated through experimental test of H-bridge voltage source inverter circuits. The data obtained from the computer simulation and prototype experiments have confirmed that that the proposed method worked well compensating the dead-time in the voltage source power inverter circuits.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2018-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v8i6.pp4880-4891</dc:identifier><dc:identifier>10.11591/ijece.v8i6.pp4880-4891</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 8 No 6 (2018); 4880</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/12233/11247</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>