Melola Discovery

← Melola Discovery

Journal

Optimization of the Performance of a Microplate Type UV-Vis Spectrophotometer as a Protein Content Testing Instrument Based on Green Analytical Chemistry (GAC)

Indonesian Journal of Chemical Science · Vol. 14 No. 3 (2025) · pp. 114–123

DOI
10.15294/ijcs.v14i3.31948
ISSN
2502-6844, 2252-6951
Published
2025-11-20
Publisher
Prodi Kimia
Language
eng

Abstract

Advancements in laboratory technology have driven the adoption of more efficient and environmentally friendly analytical methods, in line with the principles of Green Analytical Chemistry (GAC). This study aims to optimize the performance of a microplate-based UV-Vis spectrophotometer for determining protein content in food samples using the Biuret method. The method is based on a colorimetric reaction between Biuret reagent and peptide bonds in proteins, forming a purple complex whose absorbance is proportional to protein concentration. Three dilution methods were evaluated: mL-microplate, µL-microplate, and mL-cuvette, based on parameters including maximum wavelength, linearity, and accuracy. All methods showed the same maximum absorbance wavelength (562 nm), indicating reaction stability. The mL-cuvette method achieved the highest linearity (R² = 0.998), while the mL-microplate method demonstrated the best accuracy (91.00%) and most consistent results in tempeh and yogurt samples. Meanwhile, the µL-microplate method offered acceptable accuracy (90.25%) with significantly reduced reagent volume, supporting the GAC approach. Therefore, the mL-microplate method is recommended as the primary technique for protein analysis using UV-Vis spectrophotometry, while the µL-microplate method provides an efficient and eco-friendly alternative for modern laboratory applications.

Keywords

Collaboration network of the authors

40 authors · 137 co-authorship links · 3 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • State University of Semarang
  • Kanazawa University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Ella KusumastutiAffiliation unknown7
Mohammad AlauhdinAffiliation unknown4
Nuni WidiartiState University of Semarang3
Cepi KurniawanState University of Semarang3
SRI WAHYUNIAffiliation unknown3
Nanik WijayatiState University of Semarang2
Jumaeri JumaeriAffiliation unknown2
dina herminaAffiliation unknown2
Triastuti SulistyaningsihAffiliation unknown2
Edy CahyonoState University of Semarang2
Indah PrasetyowatiAffiliation unknown1
Eka IrawatiAffiliation unknown1
Siti Herlina DewiState University of Semarang1
Mohammad Haris BaihaqiAffiliation unknown1
Fika Maulydha HardiyantiAffiliation unknown1
Eka Siti RinjaniAffiliation unknown1
Sigit PriatmokoState University of Semarang1
Rr. Sri Endang PujiastutiAffiliation unknown1
Sudarmin SudarminAffiliation unknown1
Prasetyo ListiadjiAffiliation unknown1
M. SasmitaAffiliation unknown1
Dyah Rini IndriyantiState University of Semarang1
Samuel Budi Wardhana KusumaKanazawa University1
Saffanah Binti Mohd Ab AzidAffiliation unknown1
Cindy MaharaniAffiliation unknown1
Prayogo Probo AsmoroAffiliation unknown1
Rizka Ayu MelykhatunAffiliation unknown1
HarjonoState University of Semarang1
Riska Putri MawarniAffiliation unknown1
RatnawatiAffiliation unknown1
Syakilla Adha NandiantaAffiliation unknown1
Latifah LatifahAffiliation unknown1
Atika RapiernaAffiliation unknown1
Hayyu FitriahAffiliation unknown1
Eko Budi SusatyoAffiliation unknown1
Eka HartantiAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/ijcs/oai, first harvested 5 Nov 2026, last seen 5 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Optimization of the Performance of a Microplate Type UV-Vis Spectrophotometer as a Protein Content Testing Instrument Based on Green Analytical Chemistry (GAC)</dc:title>
	<dc:creator xml:lang="en">Martin Sulistyani</dc:creator>
	<dc:creator xml:lang="en">Mahatmanti, F. Widhi</dc:creator>
	<dc:creator xml:lang="en">Huda, Nuril</dc:creator>
	<dc:creator xml:lang="en">Prasetyo, Ridho</dc:creator>
	<dc:subject xml:lang="en">UV Vis Spectrophotometer</dc:subject>
	<dc:subject xml:lang="en">Protein</dc:subject>
	<dc:subject xml:lang="en">Green Analytical Chemistry</dc:subject>
	<dc:description xml:lang="en">Advancements in laboratory technology have driven the adoption of more efficient and environmentally friendly analytical methods, in line with the principles of Green Analytical Chemistry (GAC). This study aims to optimize the performance of a microplate-based UV-Vis spectrophotometer for determining protein content in food samples using the Biuret method. The method is based on a colorimetric reaction between Biuret reagent and peptide bonds in proteins, forming a purple complex whose absorbance is proportional to protein concentration. Three dilution methods were evaluated: mL-microplate, µL-microplate, and mL-cuvette, based on parameters including maximum wavelength, linearity, and accuracy. All methods showed the same maximum absorbance wavelength (562 nm), indicating reaction stability. The mL-cuvette method achieved the highest linearity (R² = 0.998), while the mL-microplate method demonstrated the best accuracy (91.00%) and most consistent results in tempeh and yogurt samples. Meanwhile, the µL-microplate method offered acceptable accuracy (90.25%) with significantly reduced reagent volume, supporting the GAC approach. Therefore, the mL-microplate method is recommended as the primary technique for protein analysis using UV-Vis spectrophotometry, while the µL-microplate method provides an efficient and eco-friendly alternative for modern laboratory applications.</dc:description>
	<dc:publisher xml:lang="en">Prodi Kimia</dc:publisher>
	<dc:date>2025-11-20</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unnes.ac.id/journals/ijcs/article/view/31948</dc:identifier>
	<dc:identifier>10.15294/ijcs.v14i3.31948</dc:identifier>
	<dc:source xml:lang="en">Indonesian Journal of Chemical Science; Vol. 14 No. 3 (2025): Indonesian Journal of Chemical Science; 114-123</dc:source>
	<dc:source>2502-6844</dc:source>
	<dc:source>2252-6951</dc:source>
	<dc:source>10.15294/ijcs.v14i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.unnes.ac.id/journals/ijcs/article/view/31948/7067</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2025 Indonesian Journal of Chemical Science</dc:rights>
</oai_dc:dc>