Melola Discovery

← Melola Discovery

Open access Journal

Performance and Energy Evaluation of Multi-Hop Network Topologies for Water Distribution Monitoring

Journal of Electrical and Intelligent Systems · Vol. 1 No. 2 (2026) · pp. 27–32

DOI
10.68129/jeis.v1i2.9
ISSN
3163-7663
Published
2026-09-30
Publisher
Politeknik Elektronika Negeri Surabaya
Language
eng
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Real-time monitoring of urban water distribution systems has become a critical requirement in modern smart urbanization, rendering traditional manual monitoring and data recording methods obsolete. To overcome these challenges, this paper presents a comprehensive study on the empirical evaluation of power consumption and communication performance in a low-cost Wireless Sensor Network (WSN) using the NRF24L01+ transceiver. Although natively restricted to basic point-to-point and single-level star topologies, a custom multi-hop routing protocol utilizing an advanced octal addressing scheme was developed to enable multi-tier network scalability. Three network topologies Star, Tree, and Series Tree were implemented and combined with two message scheduling mechanisms: By-Request polling and Round-Robin data aggregation. The system was subjected to rigorous testing under both Line-of-Sight (LOS) and Non-Line-of-Sight (NLOS) conditions across complex, obstacle-dense environments including concrete walls and heavy foliage. The experimental results reveal that the proposed multi-hop framework successfully achieves a 0% packet loss rate across seven obstacle zones where traditional Peer-to-Peer (P2P) connections fail entirely. Furthermore, the By-Request scheduling combined with a Series Tree topology demonstrated superior energy efficiency, requiring a minimal total power output of only 91.86 mWh over an operational period of one hour. Balancing data rates between 250 Kbps and 2 Mbps provides optimal real-time monitoring stability and low latency (6 ms per node). These findings provide a scalable, highly cost-effective blueprint for large-scale municipal water asset management.

Keywords

Collaboration network of the authors

22 authors · 61 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Politeknik Elektronika Negeri Surabaya
  • Panasonic (Japan)
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Iwan SyarifPoliteknik Elektronika Negeri Surabaya1
Edi SatriyantoPoliteknik Elektronika Negeri Surabaya1
Ayu Ahadi NingrumPoliteknik Elektronika Negeri Surabaya1
Rosmaliati MuchtarAffiliation unknown1
Bima Sena Bayu DewantaraPoliteknik Elektronika Negeri Surabaya1
Muhammad Wafiq KamaluddinPoliteknik Elektronika Negeri Surabaya1
Setiawardhana SetiawardhanaPoliteknik Elektronika Negeri Surabaya1
Era InsivitawatiAffiliation unknown1
Anja Asmarany RAffiliation unknown1
Ariesa Editya PratamaPanasonic (Japan)1
Faridatun NadzirohAffiliation unknown1
Nihayatus Sa'adahAffiliation unknown1
Haniah MahmudahAffiliation unknown1
Fitri FitriahAffiliation unknown1
Hari Wahjuningrat SuparnoAffiliation unknown1
Muhammad Hendra SyahputraAffiliation unknown1
Thofail SyakirudinAffiliation unknown1
Widita TrisnianiAffiliation unknown1
Oskar NatanAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://journals.pens.ac.id/index.php/jeis/oai, first harvested 6 Nov 2026, last seen 8 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Performance and Energy Evaluation of Multi-Hop Network Topologies for Water Distribution Monitoring</dc:title>
	<dc:creator xml:lang="en">Susanto, Wilhan Jechovanda</dc:creator>
	<dc:creator xml:lang="en">Gunawan, Agus Indra</dc:creator>
	<dc:creator xml:lang="en">Sudibyo, Rahardhita Widyatra</dc:creator>
	<dc:subject xml:lang="en">NRF24L01+</dc:subject>
	<dc:subject xml:lang="en">Topology</dc:subject>
	<dc:subject xml:lang="en">Communication</dc:subject>
	<dc:subject xml:lang="en">Multi-hop</dc:subject>
	<dc:subject xml:lang="en">Smart water monitoring</dc:subject>
	<dc:description xml:lang="en">Real-time monitoring of urban water distribution systems has become a critical requirement in modern smart urbanization, rendering traditional manual monitoring and data recording methods obsolete. To overcome these challenges, this paper presents a comprehensive study on the empirical evaluation of power consumption and communication performance in a low-cost Wireless Sensor Network (WSN) using the NRF24L01+ transceiver. Although natively restricted to basic point-to-point and single-level star topologies, a custom multi-hop routing protocol utilizing an advanced octal addressing scheme was developed to enable multi-tier network scalability. Three network topologies Star, Tree, and Series Tree were implemented and combined with two message scheduling mechanisms: By-Request polling and Round-Robin data aggregation. The system was subjected to rigorous testing under both Line-of-Sight (LOS) and Non-Line-of-Sight (NLOS) conditions across complex, obstacle-dense environments including concrete walls and heavy foliage. The experimental results reveal that the proposed multi-hop framework successfully achieves a 0% packet loss rate across seven obstacle zones where traditional Peer-to-Peer (P2P) connections fail entirely. Furthermore, the By-Request scheduling combined with a Series Tree topology demonstrated superior energy efficiency, requiring a minimal total power output of only 91.86 mWh over an operational period of one hour. Balancing data rates between 250 Kbps and 2 Mbps provides optimal real-time monitoring stability and low latency (6 ms per node). These findings provide a scalable, highly cost-effective blueprint for large-scale municipal water asset management.</dc:description>
	<dc:publisher xml:lang="en">Politeknik Elektronika Negeri Surabaya</dc:publisher>
	<dc:date>2026-09-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.pens.ac.id/jeis/article/view/106</dc:identifier>
	<dc:identifier>10.68129/jeis.v1i2.9</dc:identifier>
	<dc:source xml:lang="en">Journal of Electrical and Intelligent Systems; Vol. 1 No. 2 (2026): September; 27-32</dc:source>
	<dc:source>3163-7663</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.pens.ac.id/jeis/article/view/106/51</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2026 Wilhan Jechovanda Susanto, Agus Indra Gunawan, Rahardhita Widyatra Sudibyo (Author)</dc:rights>
	<dc:rights xml:lang="en">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>