Abstract

Power distribution systems play important roles in modern society. When distribution system outages occur, speedy and precise fault location is crucial in accelerating system restoration, reducing outage time and significantly improving system reliability, and then improves the quality of services and customer satisfaction. In this paper, we propose a reduced algorithm utilizing the sum of sending-end currents of the three phases to calculate the fault current, and therefore, avoid the iterative aspect of the classic algorithm for single line to ground fault location and reduce its computational charge. The test results are obtained from the numerical simulation using the data of a distribution line recognized in the literature.

Collaboration network of the authors

30 authors · 105 co-authorship links · 10 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Université Ibn-Tofail
  • Sidi Mohamed Ben Abdellah University
  • Université Moulay Ismail de Meknes
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Ismail MoufidSidi Mohamed Ben Abdellah University4
Abdelhak BendaliUniversité Ibn-Tofail4
Sanae HabibiUniversité Ibn-Tofail4
Soukaina NaciriSidi Mohamed Ben Abdellah University3
Tijani LamhamdiSidi Mohamed Ben Abdellah University3
Samia ZarrikUniversité Ibn-Tofail3
Mouad El KobbiUniversité Ibn-Tofail3
Aboubakr El MakriniSidi Mohamed Ben Abdellah University3
Zineb En-naySidi Mohamed Ben Abdellah University3
Hassan El MoussaouiSidi Mohamed Ben Abdellah University2
Abdelkader HadjoudjaUniversité Ibn-Tofail2
Zahra SahelUniversité Ibn-Tofail2
Hassan El MoussaouiSidi Mohamed Ben Abdellah University2
Mohammed El AlamiUniversité Ibn-Tofail2
Hamid TouijerUniversité Ibn-Tofail2
Elmahdi FadlaouiUniversité Ibn-Tofail1
Karima BenkhaddaUniversité Ibn-Tofail1
Alhussein BagayogoSidi Mohamed Ben Abdellah University1
Omar KabouriSidi Mohamed Ben Abdellah University1
Mohamed AzeroualUniversité Moulay Ismail de Meknes1
Reda Abid El WardiAffiliation unknown1
Mohamed Amine BenissSidi Mohamed Ben Abdellah University1
Youness BoukhrisSidi Mohamed Ben Abdellah University1
Fatehi ALtalqiUniversité Ibn-Tofail1
Omar MouhibUniversité Ibn-Tofail1
Abid Reda El WardiUniversité Ibn-Tofail1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Simplified Method for Single Line to Ground-Fault Location in Electrical Power Distribution Systems</dc:title><dc:creator>Zahri, Mustapha</dc:creator><dc:creator>Menchafou, Youssef</dc:creator><dc:creator>El Markhi, Hassane</dc:creator><dc:creator>Habibi, Mohamed</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;Power distribution systems play important roles in modern society. When distribution system outages occur, speedy and precise fault location is crucial in accelerating system restoration, reducing outage time and significantly improving system reliability, and then improves the quality of services and customer satisfaction. In this paper, we propose a reduced algorithm utilizing the sum of sending-end currents of the three phases to calculate the fault current, and therefore, avoid the iterative aspect of the classic algorithm for single line to ground fault location and reduce its computational charge. The test results are obtained from the numerical simulation using the data of a distribution line recognized in the literature.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2015-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v5i2.pp221-230</dc:identifier><dc:identifier>10.11591/ijece.v5i2.pp221-230</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 5 No 2 (2015); 221</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/5689/4746</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>