Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Binary operation based hard exudate detection and fuzzy based classification in diabetic retinal fundus images for real time diagnosis applications

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 10 No. 3 (2020)

DOI
10.11591/ijece.v10i3.pp2305-2312
ISSN
2088-8708, 2088-8708
Published
2020-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

Diabetic retinopathy (DR) is one of the most considerable reasons for visual impairment. The main objective of this paper is to automatically detect and recognize DR lesions like hard exudates, as it helps in diagnosing and screening of the disease. Here, binary operation based image processing for detecting lesions and fuzzy logic based extraction of hard exudates on diabetic retinal images are discused. In the initial stage, the binary operations are used to identify the exudates. Similarly, the RGB channel space of the DR image is used to create fuzzy sets and membership functions for extracting the exudates. The membership directives obtained from the fuzzy rule set are used to detect the grade of exudates. In order to evaluate the proposed approach, experiment tests are carriedout on various set of images and the results are verified. From the experiment results, the sensitivity obtained is 98.10%, specificity is 96.96% and accuracy is 98.2%. These results suggest that the proposed method could be a diagnostic aid for ophthalmologists in the screening for DR.

Collaboration network of the authors

7 authors · 16 co-authorship links · 7 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Noorul Islam University
  • Bule Hora University
  • Jawaharlal Nehru Technological University Anantapur
  • Sengunthar Engineering College (Autonomous)
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Eugine Prince MAffiliation unknown1
M. D. VijayakumarJawaharlal Nehru Technological University Anantapur1
P. Sujatha ThereseNoorul Islam University1
P. Josephin ShermilaAffiliation unknown1
Maris Murugan TSengunthar Engineering College (Autonomous)1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Binary operation based hard exudate detection and fuzzy based classification in diabetic retinal fundus images for real time diagnosis applications</dc:title><dc:creator>Pradeep, Arun</dc:creator><dc:creator>Joseph, X Felix</dc:creator><dc:description>&lt;jats:p&gt;Diabetic retinopathy (DR) is one of the most considerable reasons for visual impairment. The main objective of this paper is to automatically detect and recognize DR lesions like hard exudates, as it helps in diagnosing and screening of the disease. Here, binary operation based image processing for detecting lesions and fuzzy logic based extraction of hard exudates on diabetic retinal images are discused. In the initial stage, the binary operations are used to identify the exudates. Similarly, the RGB channel space of the DR image is used to create fuzzy sets and membership functions for extracting the exudates. The membership directives obtained from the fuzzy rule set are used to detect the grade of exudates. In order to evaluate the proposed approach, experiment tests are carriedout on various set of images and the results are verified. From the experiment results, the sensitivity obtained is 98.10%, specificity is 96.96% and accuracy is 98.2%.  These results suggest that the proposed method could be a diagnostic aid for ophthalmologists in the screening for DR.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2020-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v10i3.pp2305-2312</dc:identifier><dc:identifier>10.11591/ijece.v10i3.pp2305-2312</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 10 No 3 (2020); 2305</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/20001/pdf</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>