Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Enhanced sunflower optimization for placement distributed generation in distribution system

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 11 No. 1 (2021)

DOI
10.11591/ijece.v11i1.pp107-113
ISSN
2722-2578, 2088-8708
Published
2021-02-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Installation of distribution generation (DG) in the distribution system gains many technical benefits. To obtain more benefits, the location and size of DG must be selected with the appropriate values. This paper presents a method for optimizing location and size of DG in the distribution system based on enhanced sunflower optimization (ESFO) to minimize power loss of the system. In which, based on the operational mechanisms of the original sunflower optimization (SFO), a mutation technique is added for updating the best plant. The calculated results on the 33 nodes test system have shown that ESFO has proficiency for determining the best location and size of DG with higher quality than SFO. The compared results with the previous methods have also shown that ESFO outperforms to other methods in term of power loss reduction. As a result, ESFO is a reliable approach for the DG optimization problem.

Collaboration network of the authors

17 authors · 46 co-authorship links · 24 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Industrial University of Ho Chi Minh City
  • Ton Duc Thang University
  • Ho Chi Minh City University of Technology and Engineering
  • Van Lang University
  • Ho Chi Minh City University of Industry and Trade
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Thang Trung NguyenTon Duc Thang University7
Thanh Long DuongIndustrial University of Ho Chi Minh City5
Van-Duc PhanVan Lang University3
Trung Dung NguyenIndustrial University of Ho Chi Minh City2
Bach Hoang DinhTon Duc Thang University1
Tan Minh PhanTon Duc Thang University1
Ngoc Anh NguyenIndustrial University of Ho Chi Minh City1
Thanh Quyen NgoIndustrial University of Ho Chi Minh City1
Thanhquy BachIndustrial University of Ho Chi Minh City1
Nguyen Hoai PhongIndustrial University of Ho Chi Minh City1
Chiem Trong HienHo Chi Minh City University of Industry and Trade1
Ngoc Au NguyenHo Chi Minh City University of Technology and Engineering1
Trieu Ton NgocHo Chi Minh City University of Technology and Engineering1
Thanh-Phuc NguyenIndustrial University of Ho Chi Minh City1
Ly Huu PhamTon Duc Thang University1
Ngoc Thiem NguyenIndustrial University of Ho Chi Minh City1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Enhanced sunflower optimization for placement distributed generation in distribution system</dc:title><dc:creator>Nguyen, Thuan Thanh</dc:creator><dc:description>&lt;jats:p&gt;Installation of distribution generation (DG) in the distribution system gains many technical benefits. To obtain more benefits, the location and size of DG must be selected with the appropriate values. This paper presents a method for optimizing location and size of DG in the distribution system based on enhanced sunflower optimization (ESFO) to minimize power loss of the system. In which, based on the operational mechanisms of the original sunflower optimization (SFO), a mutation technique is added for updating the best plant. The calculated results on the 33 nodes test system have shown that ESFO has proficiency for determining the best location and size of DG with higher quality than SFO. The compared results with the previous methods have also shown that ESFO outperforms to other methods in term of power loss reduction. As a result, ESFO is a reliable approach for the DG optimization problem.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2021-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v11i1.pp107-113</dc:identifier><dc:identifier>10.11591/ijece.v11i1.pp107-113</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 11 No 1 (2021); 107</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/23020/14469</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>