Journal
No SINTA rank
Portable EMG System for IoT Using MQTT
Jurnal Teknik Elektro · Vol. 17 No. 2 (2024) · pp. 57–63
ISSN 2549-1571, 1411-0059
Published 2024-12-30
Publisher LPPM Universitas Negeri Semarang
Language eng
Abstract
Conventional electromyography (EMG) systems in clinical settings present limitations including high examination costs (500,000-1,500,000 IDR), bulky equipment, and lack of remote monitoring capabilities. This study develops and validates a portable Internet of Things (IoT)-based EMG system utilizing Message Queuing Telemetry Transport (MQTT) protocol for wireless muscle activity monitoring. The system integrates an EMG V3 sensor module with NodeMCU ESP8266 microcontroller, powered by dual 18650 batteries. Implementation utilized Arduino IDE and IoT MQTT Panel application. Validation comprised functional suitability testing (ISO/IEC 25010:2012), signal characteristics analysis across five subjects with 10 trials each, and repeatability precision evaluation (ISO 17025:2017). The system demonstrated 100% functional suitability. EMG signal characteristics showed average peak-to-peak voltage of 8.95±0.62 mV during relaxation and 10.48±0.58 mV during contraction, with Root Mean Square (RMS) voltage of 1.38±0.11 mV and 1.94±0.21 mV, respectively. Signal frequency-maintained consistency at approximately 50 Hz. Overall repeatability precision achieved 97.62%. This portable EMG system addresses conventional system limitations through wireless connectivity and reduced cost while maintaining measurement accuracy suitable for muscle health monitoring applications.
Collaboration network of the authors
15 authors ·
28 co-authorship links
· 5 across different organisations
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
Walisongo State Islamic University Sunan Kalijaga State Islamic University Yogyakarta Indonesian Institute of Sciences Affiliation unknown
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/jte/oai, first harvested 6 Nov 2026, last seen 8 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">Portable EMG System for IoT Using MQTT</dc:title>
<dc:creator xml:lang="en">Yuniati, Anis</dc:creator>
<dc:creator xml:lang="en">Ramadhani, Bintang</dc:creator>
<dc:creator xml:lang="en">Rakhmadi, Frida Agung</dc:creator>
<dc:creator xml:lang="en">Sumarti, Heni</dc:creator>
<dc:subject xml:lang="en">electromyography</dc:subject>
<dc:subject xml:lang="en">EMG V3 sensor module</dc:subject>
<dc:subject xml:lang="en">internet of things (IoT)</dc:subject>
<dc:subject xml:lang="en">Message Queuing Telemetry Transport (MQTT)</dc:subject>
<dc:subject xml:lang="en">NodeMCU ESP8266</dc:subject>
<dc:description xml:lang="en">Conventional electromyography (EMG) systems in clinical settings present limitations including high examination costs (500,000-1,500,000 IDR), bulky equipment, and lack of remote monitoring capabilities. This study develops and validates a portable Internet of Things (IoT)-based EMG system utilizing Message Queuing Telemetry Transport (MQTT) protocol for wireless muscle activity monitoring. The system integrates an EMG V3 sensor module with NodeMCU ESP8266 microcontroller, powered by dual 18650 batteries. Implementation utilized Arduino IDE and IoT MQTT Panel application. Validation comprised functional suitability testing (ISO/IEC 25010:2012), signal characteristics analysis across five subjects with 10 trials each, and repeatability precision evaluation (ISO 17025:2017). The system demonstrated 100% functional suitability. EMG signal characteristics showed average peak-to-peak voltage of 8.95±0.62 mV during relaxation and 10.48±0.58 mV during contraction, with Root Mean Square (RMS) voltage of 1.38±0.11 mV and 1.94±0.21 mV, respectively. Signal frequency-maintained consistency at approximately 50 Hz. Overall repeatability precision achieved 97.62%. This portable EMG system addresses conventional system limitations through wireless connectivity and reduced cost while maintaining measurement accuracy suitable for muscle health monitoring applications.</dc:description>
<dc:publisher xml:lang="en">LPPM Universitas Negeri Semarang</dc:publisher>
<dc:date>2024-12-30</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journal.unnes.ac.id/journals/jte/article/view/33839</dc:identifier>
<dc:identifier>10.15294/jte.v17i2.33839</dc:identifier>
<dc:source xml:lang="en">Jurnal Teknik Elektro; Vol. 17 No. 2 (2025); 57-63</dc:source>
<dc:source>2549-1571</dc:source>
<dc:source>1411-0059</dc:source>
<dc:source>10.15294/jte.v17i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journal.unnes.ac.id/journals/jte/article/view/33839/7918</dc:relation>
<dc:rights xml:lang="en">Copyright (c) 2025 Jurnal Teknik Elektro</dc:rights>
</oai_dc:dc>
Citations and indexing
OpenAlex
Indexed
via DOI
0 citations
Crossref
Indexed
via DOI
0 citations
Counts as reported by each index on 13 Nov 2026; indexes count citations differently.
OpenAlex also lists this work in: crossref.
Cite this article
APA 7
Yuniati, A., Ramadhani, B., Rakhmadi, F. A., & Sumarti, H. (2024). Portable EMG System for IoT Using MQTT. Jurnal Teknik Elektro, 17(2), 57–63. https://doi.org/10.15294/jte.v17i2.33839
Copy
IEEE
A. Yuniati, B. Ramadhani, F. A. Rakhmadi, and H. Sumarti, “Portable EMG System for IoT Using MQTT,” Jurnal Teknik Elektro, vol. 17, no. 2, pp. 57–63, 2024, doi: 10.15294/jte.v17i2.33839.
Copy
Generated from the journal's metadata; check author names before use.