Journal
No SINTA rank
Leakage-Aware Fault Detection in Three-Phase Power Systems Using an Artificial Neural Network and Scenario-Based Data Splitting
Jurnal Teknik Elektro · Vol. 18 No. 1 (2026) · pp. 19–33
ISSN 2549-1571, 1411-0059
Published 2026-06-30
Publisher LPPM Universitas Negeri Semarang
Language eng
Abstract
The reliability of three-phase power systems depends heavily on the ability to detect faults quickly and accurately. However, much previous research has faced challenges such as data leakage, biased evaluations due to random data splitting, and limitations in the utilisation of system dynamics-based features. This study aims to develop a machine learning-based fault detection model that is accurate, robust, and possesses high generalisation capabilities. The method employed is a quantitative approach using an Artificial Neural Network (ANN) model as a binary classifier (normal and fault). The research process includes data preprocessing, elimination of features that could potentially cause data leakage, feature engineering based on current, voltage, energy, and system imbalance, as well as scenario-based data splitting to ensure the validity of the evaluation. The model was trained using repeated cross-validation and optimised based on the Area Under the Curve (AUC) metric. The results show that the ANN model achieved high performance with an AUC of 0.987 and an accuracy of approximately 98.5% and remained stable under varying conditions such as noise and load changes. Compared to other models, Random Forest delivered the best performance, followed by Support Vector Machine (SVM) and ANN. This study addresses the gap regarding more realistic evaluation methods that are free from data leakage. Its novelty lies in the use of scenario-based splitting, comprehensive evaluation, and the finding that raw signal features make a dominant contribution to fault detection.
Collaboration network of the authors
11 authors ·
30 co-authorship links
· 13 across different organisations
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
STMIK Jayakarta Swiss German University Universitas Indraprasta PGRI State University of Medan Affiliation unknown
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Show as table
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.
Metadata source: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/jte/oai, first harvested 6 Nov 2026, last seen 22 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">Leakage-Aware Fault Detection in Three-Phase Power Systems Using an Artificial Neural Network and Scenario-Based Data Splitting</dc:title>
<dc:creator xml:lang="en">Yasin, Verdi</dc:creator>
<dc:creator xml:lang="en">Mardiyati, Sri</dc:creator>
<dc:creator xml:lang="en">Junaedi, Ifan</dc:creator>
<dc:creator xml:lang="en">Hartawan, Rumadi</dc:creator>
<dc:creator xml:lang="en">Immasari, Ito Riris</dc:creator>
<dc:creator xml:lang="en">Siagian, Ruben Cornelius</dc:creator>
<dc:subject xml:lang="en">Artificial neural network</dc:subject>
<dc:subject xml:lang="en">Energy metrics</dc:subject>
<dc:subject xml:lang="en">Machine learning</dc:subject>
<dc:subject xml:lang="en">Phase space analysis</dc:subject>
<dc:subject xml:lang="en">Power system disturbances</dc:subject>
<dc:subject xml:lang="en">Three-phase systems</dc:subject>
<dc:description xml:lang="en">The reliability of three-phase power systems depends heavily on the ability to detect faults quickly and accurately. However, much previous research has faced challenges such as data leakage, biased evaluations due to random data splitting, and limitations in the utilisation of system dynamics-based features. This study aims to develop a machine learning-based fault detection model that is accurate, robust, and possesses high generalisation capabilities. The method employed is a quantitative approach using an Artificial Neural Network (ANN) model as a binary classifier (normal and fault). The research process includes data preprocessing, elimination of features that could potentially cause data leakage, feature engineering based on current, voltage, energy, and system imbalance, as well as scenario-based data splitting to ensure the validity of the evaluation. The model was trained using repeated cross-validation and optimised based on the Area Under the Curve (AUC) metric. The results show that the ANN model achieved high performance with an AUC of 0.987 and an accuracy of approximately 98.5% and remained stable under varying conditions such as noise and load changes. Compared to other models, Random Forest delivered the best performance, followed by Support Vector Machine (SVM) and ANN. This study addresses the gap regarding more realistic evaluation methods that are free from data leakage. Its novelty lies in the use of scenario-based splitting, comprehensive evaluation, and the finding that raw signal features make a dominant contribution to fault detection.</dc:description>
<dc:publisher xml:lang="en">LPPM Universitas Negeri Semarang</dc:publisher>
<dc:date>2026-06-30</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journal.unnes.ac.id/journals/jte/article/view/40675</dc:identifier>
<dc:identifier>10.15294/jte.v18i1.40675</dc:identifier>
<dc:source xml:lang="en">Jurnal Teknik Elektro; Vol. 18 No. 1 (2026); 19-33</dc:source>
<dc:source>2549-1571</dc:source>
<dc:source>1411-0059</dc:source>
<dc:source>10.15294/jte.v18i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journal.unnes.ac.id/journals/jte/article/view/40675/10447</dc:relation>
<dc:rights xml:lang="en">Copyright (c) 2026 Jurnal Teknik Elektro</dc:rights>
</oai_dc:dc>
Citations and indexing
OpenAlex
Indexed
via DOI
1 citation
Crossref
Indexed
via DOI
1 citation
Counts as reported by each index on 13 Nov 2026; indexes count citations differently.
OpenAlex also lists this work in: crossref.
Cite this article
APA 7
Yasin, V., Mardiyati, S., Junaedi, I., Hartawan, R., Immasari, I. R., & Siagian, R. C. (2026). Leakage-Aware Fault Detection in Three-Phase Power Systems Using an Artificial Neural Network and Scenario-Based Data Splitting. Jurnal Teknik Elektro, 18(1), 19–33. https://doi.org/10.15294/jte.v18i1.40675
Copy
IEEE
V. Yasin, S. Mardiyati, I. Junaedi, R. Hartawan, I. R. Immasari, and R. C. Siagian, “Leakage-Aware Fault Detection in Three-Phase Power Systems Using an Artificial Neural Network and Scenario-Based Data Splitting,” Jurnal Teknik Elektro, vol. 18, no. 1, pp. 19–33, 2026, doi: 10.15294/jte.v18i1.40675.
Copy