Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Power dissipation analysis of PV module under partial shading

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 11 No. 2 (2021)

DOI
10.11591/ijece.v11i2.pp1029-1035
ISSN
2722-2578, 2088-8708
Published
2021-04-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Photovoltaic (PV) generation has been growing dramatically over the last years and it ranges from small, rooftop-mounted or building integrated systems, to large utility scale power stations. Especially for rooftop-mounted PV system, PV modules are serially connected to match with PV inverter input voltage specification. For serially connected PV system, shading is a problem since the shaded PV module reduces the output whole string of PV modules. The excess power from the unshaded PV module is dissipated in the shaded PV module. In this paper, power dissipation of PV module under partial shading is analyzed with circuit analysis for series connected PV modules. The specific current and voltage operating point of the shaded PV module are analyzed under shading. PSIM simulation tool is used to verify the power dissipation analysis. When there is no bypass diode and three solar modules are connected in series, upto 39.1% of the total maximum PV power is dissipated in the shaded PV module. On the other hand, when the bypass is attached, 0.3% of the total maximum power is generated as a loss in the shaded PV module. The proposed analysis technique of shaded PV module could be used in PV system performance analysis, especially for maximum power point tracking (MPPT) performance.

Collaboration network of the authors

3 authors · 2 co-authorship links · 1 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Kongju National University
  • Korea Institute of Energy Research
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Youngseok JungKorea Institute of Energy Research2

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Power dissipation analysis of PV module under partial shading</dc:title><dc:creator>Yu, Byunggyu</dc:creator><dc:creator>Ko, Seok-Cheol</dc:creator><dc:description>&lt;jats:p&gt;Photovoltaic (PV) generation has been growing dramatically over the last years and it ranges from small, rooftop-mounted or building integrated systems, to large utility scale power stations. Especially for rooftop-mounted PV system, PV modules are serially connected to match with PV inverter input voltage specification. For serially connected PV system, shading is a problem since the shaded PV module reduces the output whole string of PV modules. The excess power from the unshaded PV module is dissipated in the shaded PV module.  In this paper, power dissipation of PV module under partial shading is analyzed with circuit analysis for series connected PV modules. The specific current and voltage operating point of the shaded PV module are analyzed under shading. PSIM simulation tool is used to verify the power dissipation analysis. When there is no bypass diode and three solar modules are connected in series, upto 39.1% of the total maximum PV power is dissipated in the shaded PV module. On the other hand, when the bypass is attached, 0.3% of the total maximum power is generated as a loss in the shaded PV module.  The proposed analysis technique of shaded PV module could be used in PV system performance analysis, especially for maximum power point tracking (MPPT) performance.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2021-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v11i2.pp1029-1035</dc:identifier><dc:identifier>10.11591/ijece.v11i2.pp1029-1035</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 11 No 2 (2021); 1029</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/23859/14626</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>