In this paper, a series-fed milimeter-wave microstrip patch antenna array operating at 28 GHz is presented for wearable radio-frequency (RF) energy harvesting applications. The antenna array is made of 4×4 rectangular microstrip elements on a polyethylene terephthalate (PET) substrate to provide conformability when directly attached on human body parts. A 4-way Wilkinson power divider is connected to the array for RF power combining. The overall size of the antenna is 47×28×0.25 mm. The half-power beamwidth (HPBW) of the antenna array can be increased up to 151.9⁰ via structural deformation making it suitable for energy harvesting applications. The performance of the antenna array is investigated in terms of impedance matching, gain and radiation pattern. The average simulated specific absorption rate (SAR) of the antenna is 0.52 W/kg which is well below the safety limit of 1.6 W/kg averaged over 1 g of tissue for 100 mW of input power.
Collaboration network of the authors
4 authors ·
4 co-authorship links
Hover or tap a name to highlight its co-authors. Double-click to open the author's page.
International Islamic University Malaysia
Different organisations
Same organisation
Affiliation unknown
Thicker line = more joint articles · bigger circle = more articles
Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.