Denoising MAX6675 reading using Kalman filter and factorial design

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 11 No. 5 (2021)

DOI
10.11591/ijece.v11i5.pp3818-3827
ISSN
2722-2578, 2088-8708
Published
2021-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This paper aims to tune the Kalman filter (KF) input variables, namely measurement error and process noise, based on two-level factorial design. Kalman filter then was applied in inexpensive temperature-acquisition utilizing MAX6675 and K-type thermocouple with Arduino as its microprocessor. Two levels for each input variable, respectively, 0.1 and 0.9, were selected and applied to four K-type thermocouples mounted on MAX6675. Each sensor with a different combination of input variables was used to measure the temperature of ambient-water, boiling water, and sudden temperature drops in the system. The measurement results which consisted of the original and KF readings were evaluated to determine the optimum combination of input variables. It was found that the optimum combination of input variables was highly dependent on the system's dynamics. For systems with relatively constant dynamics, a large value of measurement error and small value of process noise results in higher precision readings. Nevertheless, for fast dynamic systems, the previous input variables' combination is less optimal because it produced a time-gap, which made the KF reading differ from the original measurement. The selection of the optimum input combination using two-level factorial design eased the KF tuning process, resulting in a more precise yet low-cost sensor.

Collaboration network of the authors

9 authors · 17 co-authorship links · 3 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Indonesia
  • Diponegoro University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
SetyowatiAffiliation unknown1
Hanny HandiyaniUniversity of Indonesia1
Diah ArruumUniversity of Indonesia1
Setyowati SetyowatiUniversity of Indonesia1
Heriandi SutadiUniversity of Indonesia1
Anggorowati AnggorowatiDiponegoro University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Denoising MAX6675 reading using Kalman filter and factorial design</dc:title><dc:creator>Septiana, Reski</dc:creator><dc:creator>Roihan, Ibnu</dc:creator><dc:creator>Koestoer, Raldi A.</dc:creator><dc:description>&lt;jats:p&gt;This paper aims to tune the Kalman filter (KF) input variables, namely measurement error and process noise, based on two-level factorial design. Kalman filter then was applied in inexpensive temperature-acquisition utilizing MAX6675 and K-type thermocouple with Arduino as its microprocessor. Two levels for each input variable, respectively, 0.1 and 0.9, were selected and applied to four K-type thermocouples mounted on MAX6675. Each sensor with a different combination of input variables was used to measure the temperature of ambient-water, boiling water, and sudden temperature drops in the system. The measurement results which consisted of the original and KF readings were evaluated to determine the optimum combination of input variables. It was found that the optimum combination of input variables was highly dependent on the system's dynamics. For systems with relatively constant dynamics, a large value of measurement error and small value of process noise results in higher precision readings. Nevertheless, for fast dynamic systems, the previous input variables' combination is less optimal because it produced a time-gap, which made the KF reading differ from the original measurement. The selection of the optimum input combination using two-level factorial design eased the KF tuning process, resulting in a more precise yet low-cost sensor.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2021-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v11i5.pp3818-3827</dc:identifier><dc:identifier>10.11591/ijece.v11i5.pp3818-3827</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 11 No 5 (2021); 3818</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/25231/15023</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>