Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

On data collection time by an electronic nose

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 11 No. 6 (2021)

DOI
10.11591/ijece.v11i6.pp4767-4773
ISSN
2722-2578, 2088-8708
Published
2021-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

We use electronic nose data of odor measurements to build machine learning classification models. The presented analysis focused on determining the optimal time of measurement, leading to the best model performance. We observe that the most valuable information for classification is available in data collected at the beginning of adsorption and the beginning of the desorption phase of measurement. We demonstrated that the usage of complex features extracted from the sensors’ response gives better classification performance than use as features only raw values of sensors’ response, normalized by baseline. We use a group shuffling cross-validation approach for determining the reported models’ average accuracy and standard deviation.

Collaboration network of the authors

5 authors · 10 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Warsaw University of Technology
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>On data collection time by an electronic nose</dc:title><dc:creator>Borowik, Piotr</dc:creator><dc:creator>Adamowicz, Leszek</dc:creator><dc:creator>Tarakowski, Rafał</dc:creator><dc:creator>Siwek, Krzysztof</dc:creator><dc:creator>Grzywacz, Tomasz</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;We use electronic nose data of odor measurements to build machine learning classification models. The presented analysis focused on determining the optimal time of measurement, leading to the best model performance. We observe that the most valuable information for classification is available in data collected at the beginning of adsorption and the beginning of the desorption phase of measurement. We demonstrated that the usage of complex features extracted from the sensors’ response gives better classification performance than use as features only raw values of sensors’ response, normalized by baseline. We use a group shuffling cross-validation approach for determining the reported models’ average accuracy and standard deviation.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2021-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v11i6.pp4767-4773</dc:identifier><dc:identifier>10.11591/ijece.v11i6.pp4767-4773</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 11 No 6 (2021); 4767</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/25696/15282</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>