Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Improving hemoglobin estimation accuracy through standardizing of light-emitting diode power

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 12 No. 1 (2022)

DOI
10.11591/ijece.v12i1.pp219-228
ISSN
2722-2578, 2088-8708
Published
2022-02-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Nowadays, hemoglobin monitoring is essential during surgeries, blood donations, and dialysis. Which are normally done using invasive methods. To monitor hemoglobin, a non-invasive hemoglobin meter was developed with five fixed light-emitting diode (LED) wavelengths at 670 nm, 770 nm, 810 nm, 850 nm, 950 nm and controlled using an Arduino Uno embedded development board. A photodetector with an on-chip trans-impedance amplifier was utilized to acquire the transmitted signal through the finger using the photoplethysmography (PPG) principle. Before the standardization of LED power, we had tested the designed system on fifteen subjects for the five wavelengths and estimated the hemoglobin with an accuracy of 96.51% and root mean square error (RMSE) of 0.57 gm/dL. To further improve the accuracy, the LED power was standardized and the PPG signal was reacquired on the same subjects. With this, the accuracy improved to 98.29% and also reduced the RMSE to 0.36 gm/dL. The designed system with LED power standardization showed a good agreement with pathology results with the coefficient of determination R 2 =0.981. Also, Bland–Altman analysis was used to evaluate the designed system and it showed good agreement between the two measurements.

Collaboration network of the authors

4 authors · 6 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Goa University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 15 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Improving hemoglobin estimation accuracy through standardizing of light-emitting diode power</dc:title><dc:creator>Pinto, Caje Francis</dc:creator><dc:creator>Parab, Jivan Shrikrishna</dc:creator><dc:creator>Sequeira, Marlon Darius</dc:creator><dc:creator>Naik, Gourish</dc:creator><dc:description>&lt;jats:p&gt;Nowadays, hemoglobin monitoring is essential during surgeries, blood donations, and dialysis. Which are normally done using invasive methods. To monitor hemoglobin, a non-invasive hemoglobin meter was developed with five fixed light-emitting diode (LED) wavelengths at 670 nm, 770 nm, 810 nm, 850 nm, 950 nm and controlled using an Arduino Uno embedded development board. A photodetector with an on-chip trans-impedance amplifier was utilized to acquire the transmitted signal through the finger using the photoplethysmography (PPG) principle. Before the standardization of LED power, we had tested the designed system on fifteen subjects for the five wavelengths and estimated the hemoglobin with an accuracy of 96.51% and root mean square error (RMSE) of 0.57 gm/dL. To further improve the accuracy, the LED power was standardized and the PPG signal was reacquired on the same subjects. With this, the accuracy improved to 98.29% and also reduced the RMSE to 0.36 gm/dL. The designed system with LED power standardization showed a good agreement with pathology results with the coefficient of determination R&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;=0.981. Also, Bland–Altman analysis was used to evaluate the designed system and it showed good agreement between the two measurements.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2022-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v12i1.pp219-228</dc:identifier><dc:identifier>10.11591/ijece.v12i1.pp219-228</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 12 No 1 (2022); 219</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/24360/15309</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>