Melola Discovery

← Melola Discovery

Journal

RANCANG BANGUN ALAT UJI KELAYAKAN PELUMAS KENDARAAN BERMOTOR BERBASIS MIKROKONTROLER

Unnes Physics Journal · Vol. 2 No. 1 (2013)

ISSN
2252-6978
Published
2013-06-12
Publisher
Unnes Physics Journal
Language
eng

Abstract

Viscosity is one of the important indicators to know the condition of the lubricant. It can be measure using falling ball method, however, this method has some disadvantage. From those disadvantages, micro-controller-based viscometer rotation has been made. The design of this tool uses DC motor with rotary encoder, micro-controller ATMega16 and LCD for the display. The data taken using new and used lubricant with the code of consistency of SAE 20W-50. The result of the measurement was that the new lubricant has higher viscosity than the used one. The more dilute the oil, the less resistance occurred in the rotation of DC motor. Yet, the result has not shown the exact value of the viscosity from the oil. The tool used has not calibrated, for to be able to be calibrated, the tool needs more improvement. The data collection was took with assumption that if oil used is standard, then the value in the range of the standard reference table. From the research of test of advisability of the micro-controller-based motorized vehicle lubricant, it is known that the rotation of viscometer with the LCD display has been able to distinguish the viscosity of new and used lubricant in numbers.

Collaboration network of the authors

29 authors · 70 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • State University of Semarang
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Achmad Rifa’iAffiliation unknown2
Abdul LatifAffiliation unknown1
Sri Wulan Siti KhotijahAffiliation unknown1
Sri Endah Ardhi Ningrum AbdullahAffiliation unknown1
Dwi AtmokoAffiliation unknown1
Achmad SopyanAffiliation unknown1
Imam GhozaliAffiliation unknown1
Ani RusilowatiState University of Semarang1
Arneta Dwi SafitrtriAffiliation unknown1
Hartono HartonoAffiliation unknown1
Nartini LestariAffiliation unknown1
KhumaediState University of Semarang1
Khisni RohendyAffiliation unknown1
- SusiloAffiliation unknown1
Retno Endah SavitriAffiliation unknown1
Vera Rizchi Cahyani PutriAffiliation unknown1
Ahmad JuheriAffiliation unknown1
sukiswo Supeni EdieAffiliation unknown1
- RohmadAffiliation unknown1
Langlang HandayaniAffiliation unknown1
Teguh DarsonoAffiliation unknown1
Slamet HaryonoAffiliation unknown1
Haydnn Caesha MaulanaAffiliation unknown1
R. IndriyantoAffiliation unknown1
Indrawan Nur CahyonoAffiliation unknown1
Aditya Bagus WicaksanaAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/sju/index.php/upj/oai, first harvested 6 Nov 2026, last seen 6 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">RANCANG BANGUN ALAT UJI KELAYAKAN PELUMAS KENDARAAN BERMOTOR BERBASIS MIKROKONTROLER</dc:title>
	<dc:creator>Febrianto, Teguh</dc:creator>
	<dc:creator>Edi, Sukiswo Supeni</dc:creator>
	<dc:creator>Sunarno, -</dc:creator>
	<dc:description xml:lang="en-US">Viscosity is one of the important indicators to know the condition of the lubricant. It can be measure using falling ball method, however, this method has some disadvantage. From those disadvantages, micro-controller-based viscometer rotation has been made. The design of this tool uses DC motor with rotary encoder, micro-controller ATMega16 and LCD for the display. The data taken using new and used lubricant with the code of consistency of SAE 20W-50. The result of the measurement was that the new lubricant has higher viscosity than the used one. The more dilute the oil, the less resistance occurred in the rotation of DC motor. Yet, the result has not shown the exact value of the viscosity from the oil. The tool used has not calibrated, for to be able to be calibrated, the tool needs more improvement. The data collection was took with assumption that if oil used is standard, then the value in the range of the standard reference table. From the research of test of advisability of the micro-controller-based motorized vehicle lubricant, it is known that the rotation of viscometer with the LCD display has been able to distinguish the viscosity of new and used lubricant in numbers.</dc:description>
	<dc:publisher xml:lang="en-US">Unnes Physics Journal</dc:publisher>
	<dc:date>2013-06-12</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unnes.ac.id/sju/upj/article/view/1363</dc:identifier>
	<dc:source xml:lang="en-US">Unnes Physics Journal; Vol 2 No 1 (2013)</dc:source>
	<dc:source>2252-6978</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.unnes.ac.id/sju/upj/article/view/1363/1334</dc:relation>
</oai_dc:dc>