Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

A new method of virtual direct torque control of doubly fed induction generator for grid connection

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 13 No. 1 (2023)

DOI
10.11591/ijece.v13i1.pp1201-1214
ISSN
2722-2578, 2088-8708
Published
2023-02-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Over the past few years, due to the shortage of fossil fuels and their unwanted environmental impacts, the use of renewable energy has vastly increased. Among them is wind power, which has been at the center of attention as one of the most important renewable energies. Many studies have been conducted regarding wind farms with variable speeds. Among these, the doubly fed induction generator (DFIG) has been of utmost importance due to its capability of separately controlling the active and reactive power, reducing the nominal converter capacity, maintaining constant variable speed frequency, and improving quality. The goal of this study is to control the synchronizing and network connection to the DFIG such that when connected to the network, no pulse is seen in the torque, rotor current, or stator. The method used in this study is known as virtual torque, which is derived from direct torque control, but instead of an electromagnetic torque, we use a virtual one. To implement this method, it is only required to measure the network voltage, current, and rotor position, and changing the control algorithm from synchronizing to grid connection only includes some changes in the flux references and torque, and calculating the electromagnetic torque instead of the virtual one.

Collaboration network of the authors

40 authors · 105 co-authorship links · 40 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Teknikal Malaysia Melaka
  • University of Technology Malaysia
  • Islamic Azad University, Tehran
  • Universitas Ahmad Dahlan
  • Diponegoro University
  • Universiti Malaysia Perlis
  • Universiti Sains Malaysia
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Auzani JidinUniversiti Teknikal Malaysia Melaka34
Nik Rumzi Nik IdrisUniversity of Technology Malaysia18
Mohammad JannatiUniversity of Technology Malaysia16
Mohd Hatta JopriUniversiti Teknikal Malaysia Melaka15
Awang JusohUniversity of Technology Malaysia15
Nik Rumzi Nik IdrisAffiliation unknown14
Mohd Junaidi Abdul AzizUniversity of Technology Malaysia10
Mustafa ManapUniversiti Teknikal Malaysia Melaka10
Kasrul Abdul KarimAffiliation unknown9
Rahim IldarabadiAffiliation unknown9
Lina HandayaniUniversitas Ahmad Dahlan8
Mohamed SalemUniversiti Sains Malaysia8
Vahdat NazerianUniversity of Mazandaran7
Abdul Rahim AbdullahUniversiti Teknikal Malaysia Melaka6
Mochammad FactaDiponegoro University6
Shahreen KasimAffiliation unknown5
Watra ArsadiandoAffiliation unknown5
Mohammad Faridun Naim TajuddinUniversiti Malaysia Perlis5
Mohd Junaidi Abdul AzizAffiliation unknown5
Imam Much Ibnu SubrotoSultan Agung Islamic University4
M. Rahimi YusoffUniversiti Teknikal Malaysia Melaka4
Muhammad AdoUniversity of Technology Malaysia4
Hendril Satrian PurnamaAffiliation unknown4
Anggit PamungkasAffiliation unknown4
Muhammad Zaid AihsanUniversiti Malaysia Perlis4
Chibuike Peter OhanuUniversity of Nigeria4
Tri WahonoAffiliation unknown4
Azralmukmin AzmiAffiliation unknown4
Shahrin Md AyobAffiliation unknown4
Siti Azura Ahmad TarusanAffiliation unknown4
Ibrahim AlhamrouniAffiliation unknown4
Aiman Zakwan JidinAffiliation unknown4
Munawar Agus RiyadiDiponegoro University3
Deris StiawanSriwijaya University3
Shahreen binti KasimTun Hussein Onn University of Malaysia3
Mehdi DadkhahIslamic Azad University, Tehran3
Mohd Arfian IsmailUniversiti Malaysia Pahang Al-Sultan Abdullah3

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 8 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>A new method of virtual direct torque control of doubly fed induction generator for grid connection</dc:title><dc:creator>Zadehbagheri, Mahmoud</dc:creator><dc:creator>Sutikno, Tole</dc:creator><dc:creator>Kiani, Mohammad Javad</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;Over the past few years, due to the shortage of fossil fuels and their unwanted environmental impacts, the use of renewable energy has vastly increased. Among them is wind power, which has been at the center of attention as one of the most important renewable energies. Many studies have been conducted regarding wind farms with variable speeds. Among these, the doubly fed induction generator (DFIG) has been of utmost importance due to its capability of separately controlling the active and reactive power, reducing the nominal converter capacity, maintaining constant variable speed frequency, and improving quality. The goal of this study is to control the synchronizing and network connection to the DFIG such that when connected to the network, no pulse is seen in the torque, rotor current, or stator. The method used in this study is known as virtual torque, which is derived from direct torque control, but instead of an electromagnetic torque, we use a virtual one. To implement this method, it is only required to measure the network voltage, current, and rotor position, and changing the control algorithm from synchronizing to grid connection only includes some changes in the flux references and torque, and calculating the electromagnetic torque instead of the virtual one.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2023-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v13i1.pp1201-1214</dc:identifier><dc:identifier>10.11591/ijece.v13i1.pp1201-1214</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 13 No 1 (2023); 1201</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/28937/16318</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>