Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

User equipment geolocation depended on long-term evolution signal-level measurements and timing advance

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 13 No. 2 (2023)

DOI
10.11591/ijece.v13i2.pp1560-1569
ISSN
2722-2578, 2088-8708
Published
2023-04-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

A new approach is described for investigating the accuracy of positioning active long-term evolution (LTE) users. The explored approach is a network-based method and depends on signal level measurements as well as the coverage of the serving cell. In a two-dimensional coordinate system, the algorithm simultaneously applies LTE measured data with a combination of a basic prediction model to locate the mobile device’s user. Furthermore, we introduce a unique method that combines timing advance (TA) and the measured signal level to narrow the search region and improve accuracy. The developed method is assessed by comparing the predicted results from the proposed algorithm with satellite measurements from the global positioning system (GPS) in various scenarios calculated via the number of cells that user equipment concurrently reports. This work separates seven different cases starting from a single reported cell to five reported cells from up to 3 sites. For analysis, the root mean square error (RMSE) is computed to obtain the validation for the proposed approach. The study case demonstrates location accuracy based on the numbers of registered cells with the mean RMSE improved using TA to approximately 70-191 m for the range of scenarios.

Collaboration network of the authors

7 authors · 19 co-authorship links · 15 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Florida Institute of Technology
  • Al-Muthanna University
  • University of Kerbala
  • Ministry of Communications
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Ali Al-SabbaghMinistry of Communications4
Ruaa AlsabahUniversity of Kerbala4

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>User equipment geolocation depended on long-term evolution signal-level measurements and timing advance</dc:title><dc:creator>Shakir, Zaenab D.</dc:creator><dc:creator>Zec, Josko</dc:creator><dc:creator>Kostanic, Ivica</dc:creator><dc:creator>Al-Thaedan, Abbas</dc:creator><dc:creator>M. Salah, Monera Elhashmi</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;A new approach is described for investigating the accuracy of positioning active long-term evolution (LTE) users. The explored approach is a network-based method and depends on signal level measurements as well as the coverage of the serving cell. In a two-dimensional coordinate system, the algorithm simultaneously applies LTE measured data with a combination of a basic prediction model to locate the mobile device’s user. Furthermore, we introduce a unique method that combines timing advance (TA) and the measured signal level to narrow the search region and improve accuracy. The developed method is assessed by comparing the predicted results from the proposed algorithm with satellite measurements from the global positioning system (GPS) in various scenarios calculated via the number of cells that user equipment concurrently reports. This work separates seven different cases starting from a single reported cell to five reported cells from up to 3 sites. For analysis, the root mean square error (RMSE) is computed to obtain the validation for the proposed approach. The study case demonstrates location accuracy based on the numbers of registered cells with the mean RMSE improved using TA to approximately 70-191 m for the range of scenarios.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2023-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v13i2.pp1560-1569</dc:identifier><dc:identifier>10.11591/ijece.v13i2.pp1560-1569</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 13 No 2 (2023); 1560</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/27314/16459</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>