Abstract

This research aims to analyze the influence of distance and direction on radiation exposure values, assess the doses received by radiation workers and the general public, and evaluate the effectiveness of radiation protection from panoramic aircraft. The research method used is an experimental research method, where the researcher directly measures the variables of the study and conducts data analysis. The study was conducted by measuring radiation doses in various directions at distances ranging from 0.5 meters to 2.5 meters forward and to the right, and 0.5 meters to 1.5 meters to the left. Dose data reception was taken at operator room, service area, corridor, and waiting room points, and radiation protection effectiveness measurements were taken at corridor entrance, waiting room, and operator room points using a survey meter. The research results indicate that the radiation exposure dose is inversely proportional to the measured distance. The dose received by radiographers in the operator room is 0.107 μSv/hour, in the employee corridor, it is 0.0856 μSv/hour, and in the public waiting room, it is 0.0856 μSv/hour. The radiation protection effectiveness value in the operator room is 94.40%, at the patient entrance from the panoramic aircraft waiting room, it is 92.12%, and at the radiographer entrance from the employee corridor, it is 94.62%. According to the Tenth Value Thickness (TVT) concept, this is considered safe because the existing protection capabilities can effectively absorb radiation.

Collaboration network of the authors

40 authors · 188 co-authorship links · 1 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universitas Muslim Indonesia
  • Sekolah Tinggi Agama Buddha Negeri Raden Wijaya Wonogiri
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Yoza FendrianiAffiliation unknown6
Frastica DeswardaniAffiliation unknown5
Tika RestianingsihAffiliation unknown5
Iful AmriAffiliation unknown5
Alrizal AlrizalAffiliation unknown4
M. Ficky AfriantoAffiliation unknown4
Samsidar SamsidarUniversitas Muslim Indonesia4
Rustan RustanAffiliation unknown3
Mardian PeslinofAffiliation unknown3
Linda HandayaniAffiliation unknown3
Cindy Nur SyaqilaAffiliation unknown2
Ilham Jaya WindhanuAffiliation unknown2
Fairuz Athaya zahran Tane TaneAffiliation unknown1
Nurhidayah NurhidayahAffiliation unknown1
Nurhidayah NurhidayahAffiliation unknown1
Rista Mutia AnggrainiAffiliation unknown1
Nurhidayah NurhidayahAffiliation unknown1
Nurhidayah NurhidayahAffiliation unknown1
Nurhidayah NurhidayahAffiliation unknown1
Heriyanti HeriyantiAffiliation unknown1
Sutrisno SutrisnoSekolah Tinggi Agama Buddha Negeri Raden Wijaya Wonogiri1
Desi AyundariAffiliation unknown1
Ardiyaningsih Puji LestariAffiliation unknown1
Dawam SuprayogiAffiliation unknown1
Dwi Rahmah AmandaAffiliation unknown1
Surya DharmaAffiliation unknown1
Jihan Suci AnandaAffiliation unknown1
Maison MaisonAffiliation unknown1
Madyawati LatiefAffiliation unknown1
Ermadani ErmadaniAffiliation unknown1
Ichy Lucya RestaAffiliation unknown1
Hesti RianyAffiliation unknown1
Muhammad Ficky AfriantoAffiliation unknown1
Andito FrayogaAffiliation unknown1
Vitri Julianta Br TariganAffiliation unknown1
Rizkia Maulida ListaAffiliation unknown1
Dimas SeptiantoAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://online-journal.unja.ac.id/index.php/jop/oai, first harvested 6 Nov 2026, last seen 6 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">ANALISIS DOSIS PAPARAN RADIASI DARI PESAWAT PANORAMIK DI INSTALASI RADIOLOGI RUMAH SAKIT UMUM DAERAH RADEN MATTAHER JAMBI</dc:title>
	<dc:creator xml:lang="en">Romarti, Chintiya</dc:creator>
	<dc:creator xml:lang="en">Pebralia, Jesi</dc:creator>
	<dc:creator xml:lang="en">Mutia Anggraini, Rista</dc:creator>
	<dc:description xml:lang="en">This research aims to analyze the influence of distance and direction on radiation exposure values, assess the doses received by radiation workers and the general public, and evaluate the effectiveness of radiation protection from panoramic aircraft. The research method used is an experimental research method, where the researcher directly measures the variables of the study and conducts data analysis. The study was conducted by measuring radiation doses in various directions at distances ranging from 0.5 meters to 2.5 meters forward and to the right, and 0.5 meters to 1.5 meters to the left. Dose data reception was taken at operator room, service area, corridor, and waiting room points, and radiation protection effectiveness measurements were taken at corridor entrance, waiting room, and operator room points using a survey meter. The research results indicate that the radiation exposure dose is inversely proportional to the measured distance. The dose received by radiographers in the operator room is 0.107 μSv/hour, in the employee corridor, it is 0.0856 μSv/hour, and in the public waiting room, it is 0.0856 μSv/hour. The radiation protection effectiveness value in the operator room is 94.40%, at the patient entrance from the panoramic aircraft waiting room, it is 92.12%, and at the radiographer entrance from the employee corridor, it is 94.62%. According to the Tenth Value Thickness (TVT) concept, this is considered safe because the existing protection capabilities can effectively absorb radiation.</dc:description>
	<dc:publisher xml:lang="en">Prodi Fisika FST UNJA</dc:publisher>
	<dc:date>2023-11-02</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://online-journal.unja.ac.id/jop/article/view/27310</dc:identifier>
	<dc:identifier>10.22437/jop.v9i1.27310</dc:identifier>
	<dc:source xml:lang="en">JOURNAL ONLINE OF PHYSICS; Vol. 9 No. 1 (2023): JOP (Journal Online of Physics) Vol 9 No 1; 90-97</dc:source>
	<dc:source>2502-2016</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://online-journal.unja.ac.id/jop/article/view/27310/16637</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2023 JOURNAL ONLINE OF PHYSICS</dc:rights>
</oai_dc:dc>