Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Data quality processing for photovoltaic system measurements

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 1 (2024)

DOI
10.11591/ijece.v14i1.pp12-21
ISSN
2722-2578, 2088-8708
Published
2024-02-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The operation and maintenance activities in photovoltaic systems use meteorological and electrical measurements that must be reliable to check system performance. The International Electrotechnical Commission (IEC) standards have established general criteria to filter erroneous information; however, there is no standardized process for the evaluation of measurements. In the present work we developed 3 procedures to detect and correct measurements of a photovoltaic system based on the single diode model. The performance evaluation of each criterion was tested with 6 groups of experimental measurements from a 3 kWp installation. Based on the error of the 3 procedures performed, the most unfavorable case has been prioritized. Then, the reduction of errors between the estimated and measured value has been achieved, reducing the number of measurements to be corrected. For the clear sky categories, the coefficient of determination is 0.9975 and 0.9961 for the high irradiance profile. Although an increase of 2.5% for coefficient of determination has been achieved, the overcast sky categories should be analyzed in more detail. Finally, the different causes of measurement error should be analyzed, associated with calibration errors and sensor quality.

Collaboration network of the authors

4 authors · 6 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universidad Nacional del Centro del Perú
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Armando CalcinaUniversidad Nacional del Centro del Perú3

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Data quality processing for photovoltaic system measurements</dc:title><dc:creator>Galarza, Jose</dc:creator><dc:creator>Condezo Hurtado, David</dc:creator><dc:creator>Saenz, Bartolome</dc:creator><dc:description>&lt;jats:p&gt;The operation and maintenance activities in photovoltaic systems use meteorological and electrical measurements that must be reliable to check system performance. The International Electrotechnical Commission (IEC) standards have established general criteria to filter erroneous information; however, there is no standardized process for the evaluation of measurements. In the present work we developed 3 procedures to detect and correct measurements of a photovoltaic system based on the single diode model. The performance evaluation of each criterion was tested with 6 groups of experimental measurements from a 3 kWp installation. Based on the error of the 3 procedures performed, the most unfavorable case has been prioritized. Then, the reduction of errors between the estimated and measured value has been achieved, reducing the number of measurements to be corrected. For the clear sky categories, the coefficient of determination is 0.9975 and 0.9961 for the high irradiance profile. Although an increase of 2.5% for coefficient of determination has been achieved, the overcast sky categories should be analyzed in more detail. Finally, the different causes of measurement error should be analyzed, associated with calibration errors and sensor quality.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i1.pp12-21</dc:identifier><dc:identifier>10.11591/ijece.v14i1.pp12-21</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 1 (2024); 12</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/32914/17055</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>