Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Development of energy conversion and lightning strike protection simulation for photovoltaic-wind turbine on grid

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 1 (2024)

DOI
10.11591/ijece.v14i1.pp66-74
ISSN
2722-2578, 2088-8708
Published
2024-02-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Photovoltaic (PV) installations and wind turbines that are installed on the rooftops of buildings need to be protected because the layout is in a high position and there is a risk of being struck by lightning. Therefore, a more effective protection system is designed to anticipate electronic damage and fire on all materials in the distribution network, especially the addition of PV and wind turbine installations on building roofs. The purpose of this study is to simulate a lightning protection system on the distribution network and the results of on-grid PV energy conversion using electrical transient analyzer program (ETAP) software. Feeder relay delay times and cascade coordination patterns between outgoing and incoming relays do not overlap. the delay time of the relay working on the feeder is 0.31 s and the coordination pattern of the outgoing relay and incoming relay does not touch each other, so the delay time for the incoming relay is 2.73 s. Then testing the results of PV energy conversion connected to the grid using MATLAB Simulink monitoring obtained data reaching 1.600 Wp at peak power with sun conditions parallel to the PV installation layout.

Collaboration network of the authors

40 authors · 128 co-authorship links · 56 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Andalas University
  • Medan Area University
  • Universitas Sumatera Utara
  • Universiti Malaysia Perlis
  • Universitas Prima Indonesia
  • National Chung Hsing University
  • Universitas Maritim Raja Ali Haji
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Muhammad Fadlan SiregarMedan Area University16
Indri DayanaMedan Area University9
M. IrwantoUniversitas Prima Indonesia7
Siti Utari RahayuNational Chung Hsing University7
Nukhe Andri SilvianaMedan Area University5
Rahmad B. Y. SyahMedan Area University5
Tino HermantoMedan Area University5
Yopan Rahmad AldoriMedan Area University5
Martha RiannaUniversitas Sumatera Utara4
Muhammad IrwantoUniversiti Malaysia Perlis4
Muzamir IsaUniversiti Malaysia Perlis4
Muhammad Yonggi PurizaUniversity of Bangka Belitung4
Andi PawawoiAndalas University3
Andreas Tiopan TogatoropAffiliation unknown3
Yanawati Binti YahyaUniversity of Kuala Lumpur3
Novizon NovizonAndalas University2
Refdinal NazirAndalas University2
Fajril AkbarAndalas University2
Rahmad SyahMedan Area University2
Thoriq Kurnia AgungAndalas University1
Dawam HabibullahAndalas University1
Benny Dwika LeonandaAndalas University1
Rindina ArmysaAndalas University1
Syukron Al- FajriAndalas University1
Kerista TariganUniversitas Sumatera Utara1
Syahrul HumaidiUniversitas Sumatera Utara1
Herri Trisna FriantoUniversitas Sumatera Utara1
Doli BonardoUniversitas Maritim Raja Ali Haji1
Yudi ArfanAndalas University1
Farah AzizahAndalas University1
Iqbal SalfikriAndalas University1
Azriyenni Azhari ZakriRiau University1
Muhammad Ridha FauziAndalas University1
Imra Nur IzrillahAndalas University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 15 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Development of energy conversion and lightning strike protection simulation for photovoltaic-wind turbine on grid</dc:title><dc:creator>Satria, Habib</dc:creator><dc:creator>Mungkin, Moranain</dc:creator><dc:creator>Dayana, Indri</dc:creator><dc:creator>Ramdan, Dadan</dc:creator><dc:creator>Maizana, Dina</dc:creator><dc:creator>Syafii, Syafii</dc:creator><dc:description>&lt;jats:p&gt;Photovoltaic (PV) installations and wind turbines that are installed on the rooftops of buildings need to be protected because the layout is in a high position and there is a risk of being struck by lightning. Therefore, a more effective protection system is designed to anticipate electronic damage and fire on all materials in the distribution network, especially the addition of PV and wind turbine installations on building roofs. The purpose of this study is to simulate a lightning protection system on the distribution network and the results of on-grid PV energy conversion using electrical transient analyzer program (ETAP) software. Feeder relay delay times and cascade coordination patterns between outgoing and incoming relays do not overlap. the delay time of the relay working on the feeder is 0.31 s and the coordination pattern of the outgoing relay and incoming relay does not touch each other, so the delay time for the incoming relay is 2.73 s. Then testing the results of PV energy conversion connected to the grid using MATLAB Simulink monitoring obtained data reaching 1.600 Wp at peak power with sun conditions parallel to the PV installation layout.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i1.pp66-74</dc:identifier><dc:identifier>10.11591/ijece.v14i1.pp66-74</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 1 (2024); 66</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/33986/17060</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>