Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Voltage and frequency control of microgrid in presence of micro-turbine interfaced to matrix converter

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 3 (2024)

DOI
10.11591/ijece.v14i3.pp2466-2479
ISSN
2722-2578, 2088-8708
Published
2024-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The active and reactive load changes have a significant impact on voltage and frequency. In this paper, in order to stabilize the microgrid (MG) against load variations in islanding mode, the active and reactive power of all distributed generators (DGs), including energy storage (battery), diesel generator, and micro-turbine, are controlled. The micro-turbine generator is connected to MG through a three-phase to three-phase matrix converter, and the droop control method is applied for controlling the voltage and frequency of MG. In addition, a method is introduced for voltage and frequency control of micro-turbines in the transition state from grid-connected mode to islanding mode. A novel switching strategy of the matrix converter is used for converting the high-frequency output voltage of the micro-turbine to the grid-side frequency of the utility system. Moreover, using the switching strategy, the low-order harmonics in the output current and voltage are not produced, and consequently, the size of the output filter would be reduced. In fact, the suggested control strategy is load-independent and has no frequency conversion restrictions. The proposed approach for voltage and frequency regulation demonstrates exceptional performance and favorable response across various load alteration scenarios. The suggested strategy is examined in several scenarios in the MG test systems, and the simulation results are addressed.

Collaboration network of the authors

40 authors · 104 co-authorship links · 38 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Teknikal Malaysia Melaka
  • University of Technology Malaysia
  • Universitas Ahmad Dahlan
  • Islamic Azad University, Tehran
  • Diponegoro University
  • Universiti Malaysia Perlis
  • Azarbaijan Shahid Madani University
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Auzani JidinUniversiti Teknikal Malaysia Melaka34
Nik Rumzi Nik IdrisUniversity of Technology Malaysia18
Mohammad JannatiUniversity of Technology Malaysia16
Mohd Hatta JopriUniversiti Teknikal Malaysia Melaka15
Awang JusohUniversity of Technology Malaysia15
Nik Rumzi Nik IdrisAffiliation unknown14
Mohd Junaidi Abdul AzizUniversity of Technology Malaysia10
Mustafa ManapUniversiti Teknikal Malaysia Melaka10
Kasrul Abdul KarimAffiliation unknown9
Lina HandayaniUniversitas Ahmad Dahlan8
Mohamed SalemUniversiti Sains Malaysia8
Mahmoud ZadehbagheriIslamic Azad University, Tehran8
Abdul Rahim AbdullahUniversiti Teknikal Malaysia Melaka6
Mochammad FactaDiponegoro University6
Mohammad Javad KianiIslamic Azad University, Tehran5
Shahreen KasimAffiliation unknown5
Watra ArsadiandoAffiliation unknown5
Mohammad Faridun Naim TajuddinUniversiti Malaysia Perlis5
Mohd Junaidi Abdul AzizAffiliation unknown5
Imam Much Ibnu SubrotoSultan Agung Islamic University4
M. Rahimi YusoffUniversiti Teknikal Malaysia Melaka4
Muhammad AdoUniversity of Technology Malaysia4
Hendril Satrian PurnamaAffiliation unknown4
Anggit PamungkasAffiliation unknown4
Vahdat NazerianUniversity of Mazandaran4
Muhammad Zaid AihsanUniversiti Malaysia Perlis4
Chibuike Peter OhanuUniversity of Nigeria4
Tri WahonoAffiliation unknown4
Rahim IldarabadiAffiliation unknown4
Azralmukmin AzmiAffiliation unknown4
Shahrin Md AyobAffiliation unknown4
Siti Azura Ahmad TarusanAffiliation unknown4
Ibrahim AlhamrouniAffiliation unknown4
Aiman Zakwan JidinAffiliation unknown4
Munawar Agus RiyadiDiponegoro University3
Deris StiawanSriwijaya University3
Shahreen binti KasimTun Hussein Onn University of Malaysia3

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 8 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Voltage and frequency control of microgrid in presence of micro-turbine interfaced to matrix converter</dc:title><dc:creator>Toupchi Khosroshahi, Mahdi</dc:creator><dc:creator>Ajami, Ali</dc:creator><dc:creator>Sutikno, Tole</dc:creator><dc:description>&lt;jats:p&gt;The active and reactive load changes have a significant impact on voltage and frequency. In this paper, in order to stabilize the microgrid (MG) against load variations in islanding mode, the active and reactive power of all distributed generators (DGs), including energy storage (battery), diesel generator, and micro-turbine, are controlled. The micro-turbine generator is connected to MG through a three-phase to three-phase matrix converter, and the droop control method is applied for controlling the voltage and frequency of MG. In addition, a method is introduced for voltage and frequency control of micro-turbines in the transition state from grid-connected mode to islanding mode. A novel switching strategy of the matrix converter is used for converting the high-frequency output voltage of the micro-turbine to the grid-side frequency of the utility system. Moreover, using the switching strategy, the low-order harmonics in the output current and voltage are not produced, and consequently, the size of the output filter would be reduced. In fact, the suggested control strategy is load-independent and has no frequency conversion restrictions. The proposed approach for voltage and frequency regulation demonstrates exceptional performance and favorable response across various load alteration scenarios. The suggested strategy is examined in several scenarios in the MG test systems, and the simulation results are addressed.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i3.pp2466-2479</dc:identifier><dc:identifier>10.11591/ijece.v14i3.pp2466-2479</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 3 (2024); 2466</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/35006/17340</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>