Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Modeling and simulation for flashover location determination on 150 kV insulator string

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 4 (2024)

DOI
10.11591/ijece.v14i4.pp3716-3728
ISSN
2722-2578, 2088-8708
Published
2024-08-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The 150 kV Payakumbuh-Koto Panjang transmission line in West Sumatra is located in an area with high lightning activity. Based on Meteorological, Climatological, and Geophysical Agency (BMKG) data (2017-2023), the average number of lightning days per year (IKL: isokeraunic level) reaches 165-173 days/year, and 79% of the transmission towers are located in hilly and rocky areas. This causes contamination of the insulator, which can reduce its performance and cause flashovers in the insulator circuit. However, in the field, finding flash points in insulators is still a challenge. Therefore, simulation must be used as a tool to determine the location of flashover in an insulator circuit that is affected by temperature and humidity. Simulation by modeling flashover provides an effective solution for determining the location of flashover in insulator circuits, which is the novelty of this research. This research compares laboratory test results with manual calculations modeled using Visual Basic 6. The research results show that temperature and humidity have a significant influence on determining the flashover voltage value on the insulator. The flashover locations during the test are the same as the calculated flashover locations, as shown by these simulations and modeling.

Collaboration network of the authors

22 authors · 75 co-authorship links · 13 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Institut Teknologi Padang
  • Andalas University
  • Politeknik Negeri Lhokseumawe
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Erhaneli ErhaneliInstitut Teknologi Padang9
Sepannur BandriInstitut Teknologi Padang8
Arfita Yuana Dewi RachmanInstitut Teknologi Padang5
Anggun AnugrahInstitut Teknologi Padang3
Abdul RajabAndalas University3
Chitra YuanisaInstitut Teknologi Padang3
Rizki Oktrinanda ElyasInstitut Teknologi Padang3
Andi M. Nur PutraInstitut Teknologi Padang3
Zulkarnaini ZulkarnainiPoliteknik Negeri Lhokseumawe2
Aswir PremadiInstitut Teknologi Padang1
Fajrin FajrinAffiliation unknown1
Al AlAffiliation unknown1
Asnal EffendiAffiliation unknown1
Muhammad Imran HamidAndalas University1
Refdinal NazirAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 8 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Modeling and simulation for flashover location determination on 150 kV insulator string</dc:title><dc:creator>Warmi, Yusreni</dc:creator><dc:creator>Amalia, Sitti</dc:creator><dc:creator>Zulkarnaini, Zulkarnaini</dc:creator><dc:creator>Dasman, Dasman</dc:creator><dc:creator>Bachtiar, Antonov</dc:creator><dc:creator>Anthony, Zuriman</dc:creator><dc:creator>Azhar, Hamdi</dc:creator><dc:description>&lt;jats:p&gt;The 150 kV Payakumbuh-Koto Panjang transmission line in West Sumatra is located in an area with high lightning activity. Based on Meteorological, Climatological, and Geophysical Agency (BMKG) data (2017-2023), the average number of lightning days per year (IKL: isokeraunic level) reaches 165-173 days/year, and 79% of the transmission towers are located in hilly and rocky areas. This causes contamination of the insulator, which can reduce its performance and cause flashovers in the insulator circuit. However, in the field, finding flash points in insulators is still a challenge. Therefore, simulation must be used as a tool to determine the location of flashover in an insulator circuit that is affected by temperature and humidity. Simulation by modeling flashover provides an effective solution for determining the location of flashover in insulator circuits, which is the novelty of this research. This research compares laboratory test results with manual calculations modeled using Visual Basic 6. The research results show that temperature and humidity have a significant influence on determining the flashover voltage value on the insulator. The flashover locations during the test are the same as the calculated flashover locations, as shown by these simulations and modeling.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i4.pp3716-3728</dc:identifier><dc:identifier>10.11591/ijece.v14i4.pp3716-3728</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 4 (2024); 3716</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/34910/17492</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>