Melola Discovery

← Melola Discovery

Open access Journal SINTA 1

Transient response of a megawatt-scale solar photovoltaic in an electric distribution utility

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 4 (2024)

DOI
10.11591/ijece.v14i4.pp3739-3754
ISSN
2722-2578, 2088-8708
Published
2024-08-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

There is an increasing trend among customers of an electrical distribution utility to adopt grid-tied solar photovoltaic systems. This shift offers multiple benefits to consumers, including lower monthly electricity bills and a contribution to the development of green energy. For the electrical distribution utility, various impacts may arise due to varying levels of solar energy penetration. This study investigates the effects of integrating varying levels of solar photovoltaic penetration into the commercial consumer network of Cagayan de Oro Electric Power and Light Company (CEPALCO) in the Philippines. Utilizing PowerWorld simulator, the research evaluates 11 different scenarios with solar penetration levels adjusted according to the percentage of load demand. Key findings include alterations in solar megavolt ampere of reactive power output, bus voltage levels, transformer power loading, and transmission line ampacity, with frequency levels remaining stable across scenarios. The optimal solar penetration level was identified at 70%, balancing the benefits of solar energy integration with the need to maintain grid stability and operational limits. This optimal level ensures the effective utilization of renewable energy sources without compromising the performance of CEPALCO’s electrical infrastructure. The research concludes with recommendations for maintaining grid stability and operational limits at the optimal solar penetration limits.

Collaboration network of the authors

2 authors · 1 co-authorship link · 1 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Science and Technology of Southern Philippines
  • Caraga State University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Oct 2026, last seen 22 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Transient response of a megawatt-scale solar photovoltaic in an electric distribution utility</dc:title><dc:creator>Judith, Paolo Justine</dc:creator><dc:creator>Dellosa, Jeffrey T.</dc:creator><dc:description>&lt;jats:p&gt;There is an increasing trend among customers of an electrical distribution utility to adopt grid-tied solar photovoltaic systems. This shift offers multiple benefits to consumers, including lower monthly electricity bills and a contribution to the development of green energy. For the electrical distribution utility, various impacts may arise due to varying levels of solar energy penetration. This study investigates the effects of integrating varying levels of solar photovoltaic penetration into the commercial consumer network of Cagayan de Oro Electric Power and Light Company (CEPALCO) in the Philippines. Utilizing PowerWorld simulator, the research evaluates 11 different scenarios with solar penetration levels adjusted according to the percentage of load demand. Key findings include alterations in solar megavolt ampere of reactive power output, bus voltage levels, transformer power loading, and transmission line ampacity, with frequency levels remaining stable across scenarios. The optimal solar penetration level was identified at 70%, balancing the benefits of solar energy integration with the need to maintain grid stability and operational limits. This optimal level ensures the effective utilization of renewable energy sources without compromising the performance of CEPALCO’s electrical infrastructure. The research concludes with recommendations for maintaining grid stability and operational limits at the optimal solar penetration limits.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i4.pp3739-3754</dc:identifier><dc:identifier>10.11591/ijece.v14i4.pp3739-3754</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 4 (2024); 3739</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/35291/17494</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>