Definite time over-current protection on transmission line using MATLAB/Simulink

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 2 (2024) · hlm. 713–723

DOI
10.11591/eei.v13i2.5301
ISSN
2089-3191, 2302-9285
Terbit
2024-02-23
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

This paper has investigated the application of the definite time over-current (DTOC) which reacts to protect the breaker from damage during the occurrence of over-current in the transmission lines. After a distance relay, this kind of over-current relay is utilized as backup protection. The overcurrent relay will provide a signal after a predetermined amount of time delay, and the breaker will trip if the distance relay does not detect a line failure. As a result, this over-current relay functions with a time delay that is just slightly longer than the combined working times of the distance relay and the breaker. This DTOC is tested for various types of faults which are 3- phase fault occurring at load 1, 3-phase fault occurring at load 2, a 3-phase fault occurring before primary protection, and the behaviour of voltage and current with a failed primary protection. All the results will be obtained using the MATLAB/Simulink software package.

Kata kunci

Jaringan kolaborasi para penulis

24 penulis · 85 tautan kepenulisan bersama · 20 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Malaysia Perlis
  • University of Mosul
  • Aksaray University
  • Northern Technical University
  • Tishk International University
  • Sohar University
  • Imam Ja’afar Al-Sadiq University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Shouket Abdulrahman AhmedUniversiti Malaysia Perlis7
Yasin BektaşAksaray University6
Sinan Q. SalihImam Ja’afar Al-Sadiq University3
Hilal A. FadhilSohar University3
Taha A. TahaAfiliasi tidak diketahui2
Abdulghafor Mohammed HashimAfiliasi tidak diketahui2
Hulusi KaracaAksaray University2
Yasir HashimTishk International University1
Firas Natheer Abdul-kadirUniversity of Mosul1
Muhammad Nazmus ShakibAfiliasi tidak diketahui1
Mohd Khair HassanAfiliasi tidak diketahui1
Noor Izzri Abdul WahabAfiliasi tidak diketahui1
Hussein I. ZaynalAfiliasi tidak diketahui1
Hazry DesaAfiliasi tidak diketahui1
Saadaldeen Rashid AhmedAfiliasi tidak diketahui1
Muthanna Ibrahim NeamahAfiliasi tidak diketahui1
Yasin BektaşAfiliasi tidak diketahui1
Khalil Farhan YassinAfiliasi tidak diketahui1
Marwa IbrahimAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Definite time over-current protection on transmission line using MATLAB/Simulink</dc:title><dc:creator>Taha A. Taha</dc:creator><dc:creator>Hussein Ibzir Zaynal</dc:creator><dc:creator>Abadal-Salam T. Hussain</dc:creator><dc:creator>Hazry Desa</dc:creator><dc:creator>Faris Hassan Taha</dc:creator><dc:subject>transmission lines</dc:subject><dc:subject>overcurrent relays</dc:subject><dc:subject>backup protection</dc:subject><dc:subject>distance relays</dc:subject><dc:subject>time delay</dc:subject><dc:subject>three-phase fault</dc:subject><dc:description xml:lang="en">This paper has investigated the application of the definite time over-current (DTOC) which reacts to protect the breaker from damage during the occurrence of over-current in the transmission lines. After a distance relay, this kind of over-current relay is utilized as backup protection. The overcurrent relay will provide a signal after a predetermined amount of time delay, and the breaker will trip if the distance relay does not detect a line failure. As a result, this over-current relay functions with a time delay that is just slightly longer than the combined working times of the distance relay and the breaker. This DTOC is tested for various types of faults which are 3- phase fault occurring at load 1, 3-phase fault occurring at load 2, a 3-phase fault occurring before primary protection, and the behaviour of voltage and current with a failed primary protection. All the results will be obtained using the MATLAB/Simulink software package.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-02-23</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>http://dx.doi.org/10.11591/eei.v13i2.5301</dc:identifier><dc:identifier>10.11591/eei.v13i2.5301</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 2 (2024); 713-723</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/5301/3597</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>