Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Human blood group type detection prototype focusing on agglutinin using microcontroller based photodiode

Bulletin of Electrical Engineering and Informatics · Vol. 13 No. 4 (2024) · hlm. 2310–2319

DOI
10.11591/eei.v13i4.7007
ISSN
2089-3191, 2302-9285
Terbit
2024-08-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Blood is a fluid in the body that mainly serves as a medium for transporting various substances in the body. Detection of human blood group types with this microcontroller utilizes dark and light properties. The dark character appears due to agglomeration, while the light nature arises because of no agglomeration, for this to happen, a liquid reagent is needed. Administration of this liquid uses the aviator's breathing oxygen (ABO) system, which consists of reagent a, reagent b, and reagent c and mixing it with blood on the test paper. The number of blood samples in each reagent is based on blood lancet. Furthermore, the sensors used to detect these properties are photodiode and light emitting diode (LED) each of 3 pieces. The Arduino Uno is used to process sensor input while at the same time producing displayed human blood group type on the display screen. The test is carried out involving 12 blood samples and a medical officer. Medical officer are tasked reading directly the results of mixing between reagents and blood samples, after that are compared with the system. The results show that the deviation of the system reading is 0.167 for the sensor reading distance with the sample as far as 0.5 cm.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 114 tautan kepenulisan bersama · 65 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Sumatera Utara
  • Telkom University
  • Politeknik Negeri Medan
  • Universitas Muhammadiyah Sumatera Utara
  • International Islamic University Malaysia
  • National Research and Innovation Agency
  • Pertamina (Indonesia)
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sarah PurnamawatiUniversitas Sumatera Utara7
Sharfina FazaPoliteknik Negeri Medan6
Mahyuddin K. M. NasutionUniversitas Sumatera Utara4
Idham KamilPoliteknik Negeri Medan4
Mhd Faris PratamaUniversitas Sumatera Utara4
Ferry FachrizalPoliteknik Negeri Medan3
Hariyadi HariyadiUniversitas Muhammadiyah Sumatera Barat3
Sinung SuakantoTelkom University2
Syahril EfendiUniversitas Sumatera Utara2
Elviawaty Muisa ZamzamiUniversitas Sumatera Utara2
Opim Salim SitompulUniversitas Sumatera Utara2
Dini Oktarina Dwi HandayaniTaylor's University2
Tien Fabrianti KusumasariTelkom University1
Lukmanul HakimInternational Islamic University Malaysia1
Hanif FakhrurrojaNational Research and Innovation Agency1
Rian Bimo AnkhalTelkom University1
Muhammad Fakhrul SafitraPertamina (Indonesia)1
Yulio FerdinandTelkom University1
Oktariani Nurul PratiwiTelkom University1
Jan M. PawlowskiAfiliasi tidak diketahui1
Litasari Widyastuti SuwarsonoTelkom University1
Joko SiswantoBandung Institute of Technology1
Syfa Nur LathifahTelkom University1
Amrullah AmrullahUniversitas Muhammadiyah Sumatera Utara1
Akbar IdamanUniversitas Satya Terra Bhinneka1
Herman MawengkangUniversitas Sumatera Utara1
Michael John WattsMedia Design School1
Anton Abdulbasah Kamilİstanbul Gelişim Üniversitesi1
Suherman SuhermanUniversitas Sumatera Utara1
Albert AlbertUniversitas Sumatera Utara1
Anggi Yohanes PardedeUniversitas Sumatera Utara1
Iqbal FakhrizaUniversitas Sumatera Utara1
Farhad NadiUNITAR International University1
M F SyahputraUniversitas Sumatera Utara1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Human blood group type detection prototype focusing on agglutinin using microcontroller based photodiode</dc:title><dc:creator>Arif Ridho Lubis</dc:creator><dc:creator>Hafid Rahman Harefa</dc:creator><dc:creator>Al-Khowarizmi Al-Khowarizmi</dc:creator><dc:creator>Julham Julham</dc:creator><dc:creator>Muharman Lubis</dc:creator><dc:creator>Romi Fadillah Rahmat</dc:creator><dc:subject>blood group typing</dc:subject><dc:subject>agglutination detection</dc:subject><dc:subject>photodiode sensor</dc:subject><dc:subject>microcontroller</dc:subject><dc:subject>Arduino Uno</dc:subject><dc:subject>ABO blood group system</dc:subject><dc:subject>reagent mixing</dc:subject><dc:description xml:lang="en">Blood is a fluid in the body that mainly serves as a medium for transporting various substances in the body. Detection of human blood group types with this microcontroller utilizes dark and light properties. The dark character appears due to agglomeration, while the light nature arises because of no agglomeration, for this to happen, a liquid reagent is needed. Administration of this liquid uses the aviator's breathing oxygen (ABO) system, which consists of reagent a, reagent b, and reagent c and mixing it with blood on the test paper. The number of blood samples in each reagent is based on blood lancet. Furthermore, the sensors used to detect these properties are photodiode and light emitting diode (LED) each of 3 pieces. The Arduino Uno is used to process sensor input while at the same time producing displayed human blood group type on the display screen. The test is carried out involving 12 blood samples and a medical officer. Medical officer are tasked reading directly the results of mixing between reagents and blood samples, after that are compared with the system. The results show that the deviation of the system reading is 0.167 for the sensor reading distance with the sample as far as 0.5 cm.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2024-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v13i4.7007</dc:identifier><dc:identifier>10.11591/eei.v13i4.7007</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 13 No 4 (2024); 2310-2319</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/7007/3772</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>