Melola Discovery

← Melola Discovery

Open access Jurnal

Performance Analysis Of Generator Set Simulator Maintenance Type Cat C32 To Support Electricity Needs In Simulator, Workshop, Mosque And Class Room I, Ii, Iii And Iv

Zona Laut Jurnal Inovasi Sains Dan Teknologi Kelautan · Vol. ume No. vember (2024) · pp. 344–354

DOI
10.62012/zl.v5i3.42269
ISSN
2721-5717, 2747-2124
Published
2024-11-27
Publisher
Departemen Teknik Kelautan Universitas Hasanuddin
Language
en
License
creativecommons.org/licenses/by/4.0

Abstract

English

The existence of a generator set is very important if there is a reduction in the main electricity supply from PLN which is conducting a blackout or under repair, then the generator set becomes an alternative power supply for electricity backup that ensures all service units at PIP Makassar are not hampered. So the role of generator facility maintenance in supplying electricity sources is very much needed to support performance, so efficiency is needed in the maintenance management process, especially on the CAT C.32 type generator set with a power capacity of 800 KVA which supports all activities in the simulator and other units. The purpose of this study is to analyze the burden of electricity supply needs on the service unit and to find out the right actions in maintaining the generator set engine components in the simulator so as not to hinder activities towards the learning process. However, other rooms do not have adequate generator supply or are not even available at all maximally based on the needs of the room/unit but are only concentrated on the simulator generator set supply unit. This results in an overload on the generator set which can cause serious damage to its internal component system, which makes the engine and alternator work harder, and are at risk of overheating, decreased efficiency, and even functional failure. That there has been a use of electric current of 401,370 watts or 1,825 amperes (50%), the simulator of 267,320 watts or 1,215 watts (33%), the Workshop of 114,088 or 519 amperes (14%) and the Mosque of 37,600 watts or 171 amperes (5%), so that the availability of generator power is 800 KW and has exceeded the use of 94 amperes or 102% with the category of Attention or overload.

Bahasa Indonesia

Keberadaan generator set sangat penting jika terjadi pengurangan pasokan listrik utama dari PLN yang sedang melakukan pemadaman atau dalam perbaikan, maka genset menjadi alternatif power supply untuk cadangan listrik yang memastikan semua unit layanan di PIP Makassar tidak terhambat. Sehingga peran perawatan fasilitas generator dalam mensuplai sumber listrik sangatlah diperlukan untuk menunjang performansi, maka dibutuhkan efisiensi dalam proses manajemen perawatan khususnya pada mesin genset type CAT C.32 dengan kapasitas daya 800 KVA yang memsupport seluruh kegiatan di simulator dan unit lainnya. Tujuan penelitian ini untuk menganalisa beban kebutuhan suplai listrik pada unit layanan dan mengetahui tindakan yang tepat pada perawatan komponen-komponen mesin genset di simulator agar tidak menghambat kegiatan terhadap proses pembelajaran. Namun ruangan yang lain tidak memiliki suplai genset yang memadai atau bahkan sama sekali tidak tersedia secara maximal berdasarkan kebutuhan ruangan/unit tetapi hanya terkonsentrasi pada unit suplay genset simulator. Sehingga mengakibatkan kelebihan beban pada genset yang dapat menyebabkan kerusakan serius pada sistem komponen internalnya, yang membuat mesin dan alternator, akan bekerja lebih keras, dan berisiko mengalami panas berlebih (overheating), penurunan efisiensi, hingga kegagalan fungsi. Bahwa telah terjadi pemakaian arus listrik sebesar 401.370 watt atau 1.825 ampere, (50%), simulator sebesar 267.320 watt atau 1.215 watt (33%), Workshop sebesar 114.088 atau 519 ampere (14%) dan Mesjid sebesar 37.600 watt atau 171 ampere (5%), sehingga ketersediaan daya genset 800 KW dan telah melebihi pemakaian sebesar 94 ampere atau 102 % dengan kategori Perhatian atau terjadi kelebihan beban.

Keywords

Collaboration network of the authors

10 authors · 17 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Institut Agama Islam Negeri Kendari
  • University of Mataram
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Suyuti SuyutiAffiliation unknown2
Muhammad Arifin IlhamInstitut Agama Islam Negeri Kendari1
Muh. Syarwa SangilaAffiliation unknown1
JamaluddinUniversity of Mataram1
MusriadyAffiliation unknown1
Jamaluddin JamaluddinAffiliation unknown1
Musriady MusriadyAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://journal.unhas.ac.id/index.php/zonalaut/oai, first harvested 2 Nov 2026, last seen 2 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Performance Analysis Of Generator Set Simulator Maintenance Type Cat C32 To Support Electricity Needs In Simulator, Workshop, Mosque And Class Room I, Ii, Iii And Iv</dc:title>
	<dc:title xml:lang="id">Performance Analysis Of Generator Set Simulator Maintenance Type Cat C32 To Support Electricity Needs In Simulator, Workshop, Mosque And Class Room I, Ii, Iii And Iv</dc:title>
	<dc:creator xml:lang="en">Jafar, Muh</dc:creator>
	<dc:creator xml:lang="en">Dandduru, Arifin</dc:creator>
	<dc:creator xml:lang="en">Amalia, Reski</dc:creator>
	<dc:creator xml:lang="id">Jafar, Muh</dc:creator>
	<dc:creator xml:lang="id">Dandduru, Arifin</dc:creator>
	<dc:creator xml:lang="id">Amalia, Reski</dc:creator>
	<dc:subject xml:lang="en">Generator Set</dc:subject>
	<dc:subject xml:lang="en">Power Supply</dc:subject>
	<dc:subject xml:lang="en">Maintenance</dc:subject>
	<dc:description xml:lang="en">The existence of a generator set is very important if there is a reduction in the main electricity supply from PLN which is conducting a blackout or under repair, then the generator set becomes an alternative power supply for electricity backup that ensures all service units at PIP Makassar are not hampered. So the role of generator facility maintenance in supplying electricity sources is very much needed to support performance, so efficiency is needed in the maintenance management process, especially on the CAT C.32 type generator set with a power capacity of 800 KVA which supports all activities in the simulator and other units. The purpose of this study is to analyze the burden of electricity supply needs on the service unit and to find out the right actions in maintaining the generator set engine components in the simulator so as not to hinder activities towards the learning process. However, other rooms do not have adequate generator supply or are not even available at all maximally based on the needs of the room/unit but are only concentrated on the simulator generator set supply unit. This results in an overload on the generator set which can cause serious damage to its internal component system, which makes the engine and alternator work harder, and are at risk of overheating, decreased efficiency, and even functional failure. That there has been a use of electric current of 401,370 watts or 1,825 amperes (50%), the simulator of 267,320 watts or 1,215 watts (33%), the Workshop of 114,088 or 519 amperes (14%) and the Mosque of 37,600 watts or 171 amperes (5%), so that the availability of generator power is 800 KW and has exceeded the use of 94 amperes or 102% with the category of Attention or overload.</dc:description>
	<dc:description xml:lang="id">Keberadaan generator set sangat penting jika terjadi pengurangan pasokan listrik utama dari PLN yang sedang melakukan pemadaman atau dalam perbaikan, maka genset menjadi alternatif power supply untuk cadangan listrik yang memastikan semua unit layanan di PIP Makassar tidak terhambat. Sehingga peran perawatan fasilitas generator dalam mensuplai sumber listrik sangatlah diperlukan untuk menunjang performansi, maka dibutuhkan efisiensi dalam proses manajemen perawatan khususnya pada mesin genset type CAT C.32 dengan kapasitas daya 800 KVA yang memsupport seluruh kegiatan di simulator dan unit lainnya. Tujuan penelitian ini untuk menganalisa beban kebutuhan suplai listrik pada unit layanan dan mengetahui tindakan yang tepat pada perawatan komponen-komponen mesin genset di simulator agar tidak menghambat kegiatan terhadap proses pembelajaran. Namun ruangan yang lain tidak memiliki suplai genset yang memadai atau bahkan sama sekali tidak tersedia secara maximal berdasarkan kebutuhan ruangan/unit tetapi hanya terkonsentrasi pada unit suplay genset simulator. Sehingga mengakibatkan kelebihan beban pada genset yang dapat menyebabkan kerusakan serius pada sistem komponen internalnya, yang membuat mesin dan alternator, akan bekerja lebih keras, dan berisiko mengalami panas berlebih (overheating), penurunan efisiensi, hingga kegagalan fungsi. Bahwa telah terjadi pemakaian arus listrik sebesar 401.370 watt atau 1.825 ampere, (50%), simulator sebesar 267.320 watt atau 1.215 watt (33%), Workshop sebesar 114.088 atau 519 ampere (14%) dan Mesjid sebesar 37.600 watt atau 171 ampere (5%), sehingga ketersediaan daya genset 800 KW dan telah melebihi pemakaian sebesar 94 ampere atau 102 % dengan kategori Perhatian atau terjadi kelebihan beban.</dc:description>
	<dc:publisher xml:lang="en">Departemen Teknik Kelautan Universitas Hasanuddin</dc:publisher>
	<dc:date>2024-11-27</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unhas.ac.id/index.php/zonalaut/article/view/42269</dc:identifier>
	<dc:identifier>10.62012/zl.v5i3.42269</dc:identifier>
	<dc:source xml:lang="en">Zona Laut Jurnal Inovasi Sains Dan Teknologi Kelautan; Volume 5, Number 3, November 2024 Edition; 344-354</dc:source>
	<dc:source xml:lang="id">Zona Laut : Jurnal Inovasi Sains Dan Teknologi  Kelautan; Volume 5, Number 3, November 2024 Edition; 344-354</dc:source>
	<dc:source>2721-5717</dc:source>
	<dc:source>2747-2124</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://journal.unhas.ac.id/index.php/zonalaut/article/view/42269/12532</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2024 Muh Jafar, Arifin Dandduru, Reski Amalia</dc:rights>
	<dc:rights xml:lang="en">https://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>