Melola Discovery

← Melola Discovery

Jurnal

Optimization of the Performance of a Microplate Type UV-Vis Spectrophotometer as a Protein Content Testing Instrument Based on Green Analytical Chemistry (GAC)

Indonesian Journal of Chemical Science · Vol. 14 No. 3 (2025) · hlm. 114–123

DOI
10.15294/ijcs.v14i3.31948
ISSN
2502-6844, 2252-6951
Terbit
2025-11-20
Penerbit
Prodi Kimia
Bahasa
eng

Abstrak

Advancements in laboratory technology have driven the adoption of more efficient and environmentally friendly analytical methods, in line with the principles of Green Analytical Chemistry (GAC). This study aims to optimize the performance of a microplate-based UV-Vis spectrophotometer for determining protein content in food samples using the Biuret method. The method is based on a colorimetric reaction between Biuret reagent and peptide bonds in proteins, forming a purple complex whose absorbance is proportional to protein concentration. Three dilution methods were evaluated: mL-microplate, µL-microplate, and mL-cuvette, based on parameters including maximum wavelength, linearity, and accuracy. All methods showed the same maximum absorbance wavelength (562 nm), indicating reaction stability. The mL-cuvette method achieved the highest linearity (R² = 0.998), while the mL-microplate method demonstrated the best accuracy (91.00%) and most consistent results in tempeh and yogurt samples. Meanwhile, the µL-microplate method offered acceptable accuracy (90.25%) with significantly reduced reagent volume, supporting the GAC approach. Therefore, the mL-microplate method is recommended as the primary technique for protein analysis using UV-Vis spectrophotometry, while the µL-microplate method provides an efficient and eco-friendly alternative for modern laboratory applications.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 137 tautan kepenulisan bersama · 3 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • State University of Semarang
  • Kanazawa University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ella KusumastutiAfiliasi tidak diketahui7
Mohammad AlauhdinAfiliasi tidak diketahui4
Nuni WidiartiState University of Semarang3
Cepi KurniawanState University of Semarang3
SRI WAHYUNIAfiliasi tidak diketahui3
Nanik WijayatiState University of Semarang2
Jumaeri JumaeriAfiliasi tidak diketahui2
dina herminaAfiliasi tidak diketahui2
Triastuti SulistyaningsihAfiliasi tidak diketahui2
Edy CahyonoState University of Semarang2
Indah PrasetyowatiAfiliasi tidak diketahui1
Eka IrawatiAfiliasi tidak diketahui1
Siti Herlina DewiState University of Semarang1
Mohammad Haris BaihaqiAfiliasi tidak diketahui1
Fika Maulydha HardiyantiAfiliasi tidak diketahui1
Eka Siti RinjaniAfiliasi tidak diketahui1
Sigit PriatmokoState University of Semarang1
Rr. Sri Endang PujiastutiAfiliasi tidak diketahui1
Sudarmin SudarminAfiliasi tidak diketahui1
Prasetyo ListiadjiAfiliasi tidak diketahui1
M. SasmitaAfiliasi tidak diketahui1
Dyah Rini IndriyantiState University of Semarang1
Samuel Budi Wardhana KusumaKanazawa University1
Saffanah Binti Mohd Ab AzidAfiliasi tidak diketahui1
Cindy MaharaniAfiliasi tidak diketahui1
Prayogo Probo AsmoroAfiliasi tidak diketahui1
Rizka Ayu MelykhatunAfiliasi tidak diketahui1
HarjonoState University of Semarang1
Riska Putri MawarniAfiliasi tidak diketahui1
RatnawatiAfiliasi tidak diketahui1
Syakilla Adha NandiantaAfiliasi tidak diketahui1
Latifah LatifahAfiliasi tidak diketahui1
Atika RapiernaAfiliasi tidak diketahui1
Hayyu FitriahAfiliasi tidak diketahui1
Eko Budi SusatyoAfiliasi tidak diketahui1
Eka HartantiAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/ijcs/oai, pertama di-harvest 5 Nov 2026, terakhir terlihat 5 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Optimization of the Performance of a Microplate Type UV-Vis Spectrophotometer as a Protein Content Testing Instrument Based on Green Analytical Chemistry (GAC)</dc:title>
	<dc:creator xml:lang="en">Martin Sulistyani</dc:creator>
	<dc:creator xml:lang="en">Mahatmanti, F. Widhi</dc:creator>
	<dc:creator xml:lang="en">Huda, Nuril</dc:creator>
	<dc:creator xml:lang="en">Prasetyo, Ridho</dc:creator>
	<dc:subject xml:lang="en">UV Vis Spectrophotometer</dc:subject>
	<dc:subject xml:lang="en">Protein</dc:subject>
	<dc:subject xml:lang="en">Green Analytical Chemistry</dc:subject>
	<dc:description xml:lang="en">Advancements in laboratory technology have driven the adoption of more efficient and environmentally friendly analytical methods, in line with the principles of Green Analytical Chemistry (GAC). This study aims to optimize the performance of a microplate-based UV-Vis spectrophotometer for determining protein content in food samples using the Biuret method. The method is based on a colorimetric reaction between Biuret reagent and peptide bonds in proteins, forming a purple complex whose absorbance is proportional to protein concentration. Three dilution methods were evaluated: mL-microplate, µL-microplate, and mL-cuvette, based on parameters including maximum wavelength, linearity, and accuracy. All methods showed the same maximum absorbance wavelength (562 nm), indicating reaction stability. The mL-cuvette method achieved the highest linearity (R² = 0.998), while the mL-microplate method demonstrated the best accuracy (91.00%) and most consistent results in tempeh and yogurt samples. Meanwhile, the µL-microplate method offered acceptable accuracy (90.25%) with significantly reduced reagent volume, supporting the GAC approach. Therefore, the mL-microplate method is recommended as the primary technique for protein analysis using UV-Vis spectrophotometry, while the µL-microplate method provides an efficient and eco-friendly alternative for modern laboratory applications.</dc:description>
	<dc:publisher xml:lang="en">Prodi Kimia</dc:publisher>
	<dc:date>2025-11-20</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unnes.ac.id/journals/ijcs/article/view/31948</dc:identifier>
	<dc:identifier>10.15294/ijcs.v14i3.31948</dc:identifier>
	<dc:source xml:lang="en">Indonesian Journal of Chemical Science; Vol. 14 No. 3 (2025): Indonesian Journal of Chemical Science; 114-123</dc:source>
	<dc:source>2502-6844</dc:source>
	<dc:source>2252-6951</dc:source>
	<dc:source>10.15294/ijcs.v14i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.unnes.ac.id/journals/ijcs/article/view/31948/7067</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2025 Indonesian Journal of Chemical Science</dc:rights>
</oai_dc:dc>